DeepSea® Marine Cable NEK 606 P112 (P19 or P19/P21) TFOU; 12/20(24)kV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 03 conductors; XLPE / LSOH / SHF2 – SHF2 MUD; Flame Retardant; +90°C

DeepSea® Medium Voltage Marine Cable – Flame Retardant SHF2 P112 (P19 or P19/P21) TFOU 12/20(24)kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

DeepSea® NEK606 Offshore Cable: Safety and Reliability in Medium VoltageDeveloped for the harshest conditions in marine and offshore environments. This cable features a robust construction that ensures maximum protection, performance, and continuous power transmission, guaranteeing the integrity of your operation.
  • Maximum security: Flame retardant, with low smoke emission and completely halogen-free to protect lives.
  • High durability: It has robust armor and a special coating that is resistant to mud and oils.
  • Superior confidence: Tinned copper conductors that guarantee stable and much longer-lasting electrical performance.
  • Guaranteed quality: Approved and certified according to the most stringent global standards, such as IEC and NEK 606.
  • Application versatility: It is the ideal solution for fixed medium-voltage installations on platforms and ships.
PRODUCT DESIGN
  • Conductors: Tin-plated and annealed circular stranded copper according to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). TFOU
  • Insulation screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Mesh of tinned copper wires according to IEC 60092-350.
  • External Coating: Halogen-free thermoset compound, SHF2 (for the former TYPE P19), or halogen-free mud-resistant thermoset compound, SHF MUD (for the former TYPE P19/P21), in red.
DETAILS

Benefits

  • Enhanced Security: Halogen-free construction, with low smoke emission and flame retardant properties, ideal for confined areas.
  • Maximum Resistance: Designed to withstand the most aggressive offshore environments, including mud and drilling fluids.
  • Superior Mechanical Protection: Armor with a braid of tinned copper wires that offers robustness against impacts and crushing.
  • High Durability: Excellent resistance to moisture, high temperatures, oils, and harsh marine conditions, ensuring a long service life.
  • Reliable Conductivity: Tinned copper conductors that ensure superior electrical performance and excellent corrosion resistance.
  • Installation Flexibility: The braided armor makes the cable more flexible, facilitating assembly in hard-to-reach places and with curves.
  • Operation in Extreme Temperatures: Suitable for safe operation in a wide temperature range, from -20°C to +90°C.
  • Effective Shielding: The copper braid acts as an efficient shield against electromagnetic interference.
  • Lightness and Versatility: Lighter than cables with other armoring, which is an advantage in installations where weight is a critical factor.
  • Compliance with Standards: Manufactured according to the stringent NEK 606 and IEC standards, guaranteeing quality and safety.

Applications

  • Oil and Gas Platforms: Medium voltage power supply for drilling, production and processing equipment.
  • Naval and Maritime Industry: Perfect for fixed electrical installations on ships, drilling rigs, and other vessels.
  • Critical Emergency Systems: Reliable power supply for lighting systems, alarms, and security equipment.
  • Classified Areas (Ex): It can be safely installed in both safe areas and explosion-risk zones.
  • Drilling Equipment: Its resistance to mud and chemicals makes it ideal for powering engines and systems in drilling rigs.
  • Offshore Power Distribution: Used in medium-voltage power supply and distribution circuits in general.
  • Harsh Industrial Environments: Applications in chemical plants, refineries, and locations with corrosive agents.
  • Lighting and Control Systems: Power supply for control panels, instrumentation, and lighting systems in marine environments.
  • Electromechanical Equipment: Connection of motors, pumps, compressors and other large equipment.
  • Fixed Medium Voltage Installations: A robust solution for any project that requires a safe and durable power cable.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeP112 (Formerly P19 or P19/P21) TFOU 12/20(24)kV - Medium Voltage Cables for Offshore & Marine
ApplicationsFixed installation for medium voltage power. They are flame retardant, low smoke emission, halogen-free and mud resistant.
Electrical Parameters
Operating Voltage12/20 (24) kV
Maximum DC Resistance of the Conductor at 20°CRanges from 1,16 Ω/km (16 mm²) to 0,0607 Ω/km (300 mm²)
DC Capacity @45°C (1 Core)It ranges from 96 A (16 mm²) to 601 A (300 mm²)
DC Capacity @45°C (3 Cores)It ranges from 67 A (16 mm²) to 421 A (300 mm²)
Short-Circuit Current (1s)It ranges from 2290 A (16 mm²) to 42930 A (300 mm²)
Product Design
Conductor MaterialCircular tin-plated braided wire, class 2 or 5 according to IEC 60228.
Driver's ScreenSemiconductor material.
InsulationHalogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). TFOU
Isolation ScreenSemiconductor material and tinned copper wire mesh.
Separator (Bedding)Halogen-free compound.
ArmorTinned copper wire mesh conforming to IEC 60092-350.
External CoverHalogen-free thermosetting compound, SHF2, or halogen-free, mud-resistant thermosetting compound, SHF MUD.
Cover ColorRed.
Mechanical and Thermal Characteristics
Radius of Curvature15 x External Diameter (during installation); 9 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Ambient Temperature Correction FactorsFactor of 1.1 (35°C) to 0.47 (80°C).
Applicable Standards
NEK 606:2016IEC 60092-354
IEC 60092-360IEC 60332-1
IEC 60332 3 22IEC 60754-1,2
IEC 61034-1,2IEC 60228
IEC 60092-350-
Ambient Temperature (°C)35404550556065707580
Classification Factor1.101.051.00.940.880.820.740.670.580.47
DIMENSIONAL TABLE
Construction (Number x mm²)Section Area (mm²)Conductor Diameter (mm)Insulation Thickness (mm)Internal Cover Thickness (mm)External Cover Thickness (mm)External Diameter (mm)Nominal Weight (kg/km)Maximum DC Resistance @20°C (Ω/km)Direct Current @45°C (1 Conductor) (A)Direct Current @45°C (3 Conductors) (A)Short-Circuit Current (1s) (A)
1 x 16165.25.51.21.428.012001.1696672290
1 x 25256.55.51.21.531.61530734127893580
1 x 35357.45.51.31.832.315955291571105010
1 x 50508.75.51.81.433.817953911961377150
1 x 707010.35.51.91.434.620700.2724216910020
1 x 959512.25.52.01.537.0247019529320513590
1 x 12012013.85.52.01.538.8281015433923717170
1 x 15015015.15.52.11.640.7324512638927221460
1 x 18518517.05.52.21.642.937650.144431126470
1 x 24024019.65.52.31.745.8451076252236534340
1 x 30030021.95.52.41.848.5531560760142142930
3 x 16165.25.51.82.055.549501.1696672290
3 x 25256.55.51.92.062.25705734127893580
3 x 35357.45.52.92.162.659905291571105010
3 x 50508.75.53.02.265.467403911961377150
3 x 707010.35.53.12.369.177900.2724216910020
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.