DeepSea® Marine Cable NEK 606 P113 TFOU; 18/30 (36)kV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 03 conductors; XLPE / LSOH / SHF2 – SHF2 MUD; Flame Retardant; +90°C

DeepSea® Medium Voltage Marine Cable – Flame Retardant SHF2 P113 TFOU 18/30 (36)kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK606 Medium Voltage Cable for Critical ApplicationsDesigned for the most demanding medium-voltage installations, this cable offers maximum safety and reliability in offshore and marine environments, even under the harshest conditions. Ensure the continuity of your operation with a superior engineered solution built to last.
  • Maximum Security: Flame-retardant, halogen-free, and low-smoke construction to protect lives and essential equipment.
  • Extreme Durability: Resistant to mud and with tinned copper shielding to withstand the harshest environments.
  • Superior Performance: XLPE insulation ensures continuous operation from -20°C to +90°C.
  • Certified Quality: Full compliance with the stringent NEK 606 and IEC standards, ensuring complete peace of mind.
  • Uninterrupted Power: The ideal solution for powering critical systems in fixed installations on ships and platforms.
PRODUCT DESIGN
  • Conductors: Tin-plated and annealed circular stranded copper according to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).TFOU
  • Insulation screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Mesh of tinned copper wires according to IEC 60092-350.
  • External Coating: Halogen-free thermosetting compound, SHF2, in red.
DETAILS

Benefits

  • Maximum Fire Safety: Low smoke emission, halogen-free and flame retardant construction.
  • High Durability: SHF2 outer sheath and tinned copper armor for robust mechanical protection.
  • Resistance to Harsh Environments: Designed to withstand drilling mud and harsh marine conditions.
  • Power Reliability: Ideal for fixed medium-voltage installations, ensuring a stable power supply.
  • Wide Operating Range: Safe performance in temperatures ranging from -20°C to +90°C.
  • Corrosion Protection: Tinned copper conductors that prevent oxidation in saline environments.
  • Excellent Electrical Performance: XLPE insulation and semiconductor shielding ensure signal integrity.
  • Secure Installation: Proper flexibility for defined bending radii, optimizing assembly.
  • International Compliance: Certified to the stringent NEK 606 and IEC standards for offshore use.

Applications

  • Oil and Gas Platforms: Power supply, control and instrumentation systems in fixed or floating units.
  • Ships and Vessels: Medium voltage power distribution in cruise ships, cargo ships and drill ships.
  • Floating Production Storage and Offloading (FPSO) Units: For essential power systems on production, storage and transfer vessels.
  • Drilling Probes: Providing power to drilling equipment and critical onboard operations.
  • Naval Industry: Electrical installations in shipyards and during the construction of new vessels.
  • Port Terminals: Power supply for cranes, gantries, and other heavy equipment in coastal areas.
  • Offshore Wind Farms: Connecting turbines and substations in offshore renewable energy projects.
  • Support Vessels: Power supply for propulsion systems and equipment on offshore support vessels.
  • Accommodation Modules: Safe distribution of electricity in residential areas on platforms.
  • Emergency Systems: Power circuits that require high safety and reliability in case of fire.
TECHNICAL DATA

 

General information
BrandInnovcable DeepSea®
Product typeMedium Voltage Cable for Offshore and Marine Applications (P113 TFOU).
ApplicationUsed for fixed medium-voltage power installations. It is flame retardant, has low smoke emission, is halogen-free, and mud-resistant.
Electrical Parameters
Operating Voltage18/30 (36) kV
Maximum DC Resistance of the Conductor @20°CIt varies according to the cross-section (e.g., 0,391 Ω/km for 50 mm²; 0,0607 Ω/km for 300 mm²).
DC Capacity @45°CIt varies according to the cross-sectional area and the number of conductors (e.g., 1 conductor 50mm² = 196 A; 3 conductors 50mm² = 137 A).
Short-Circuit Current (1s)It varies according to the cross-section (e.g., 50 mm² = 7150 A; 300 mm² = 42930 A).
Temperature Correction FactorsFactors applicable for ambient temperatures from 35°C to 80°C (e.g., 45°C = 1.0; 60°C = 0.82; 80°C = 0.47).
Product Design
Conductor MaterialBraided, circular, ringed, and tinned copper.
Driver ClassClass 2 or Class 5, according to IEC 60228.
Driver's ScreenSemiconductor material.
Insulation MaterialHalogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). TFOU
Isolation ScreenSemiconductor material and tinned copper wire braid.
Inner Cover (Bedding)Halogen-free compound.
ArmorBraid of tinned copper wire.
Exterior Roofing MaterialHalogen-free thermosetting compound, type SHF2.
Cover ColorRed.
Product Features and Properties
Temperature Range-20 ° C to + 90 ° C.
Minimum Bending Radius (Installation)15 x Outer Diameter.
Minimum Radius of Curvature (Fixed)9 x Outer Diameter.
Flame retardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Low smoke emissionYes, in accordance with IEC 61034-1,2.
Halogen-freeYes, in accordance with IEC 60754-1,2.
Mud resistantYes.
Dimensions and Weight
Nominal Outside DiameterIt varies depending on the construction (e.g., 1x50mm² = 41 mm; 3x50mm² = 81 mm).
Nominal WeightIt varies depending on the construction (e.g., 1x50mm² = 2390 kg/km; 3x50mm² = 7470 kg/km).
Nominal Insulation Thickness8.0 mm.
Applicable Standards
Reference normNEK 606:2016
Other StandardsIEC 60092-354, IEC 60092-360, IEC 60332-1, IEC 60332-3-22, IEC 60754-1,2, IEC 61034-1,2, IEC 60228.

 

DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area mm²)Nominal Conductor Diameter (mm)Maximum DC Resistance @20°C (Ω/km)Rated Direct Current @45°C 1 Conductor (A)Rated Direct Current @45°C 3 Conductors (A)Short-Circuit Current 1s (A)Nominal Insulation Thickness (mm)Diameter under the armor (mm)Nominal Outside Diameter (mm)
Nominal Weight (kg/km)
1 x 508.739119671508.033.8412390
1 x 7010.30.27242100208.035.5432700
1 x 9512.2195293135908.037.3453100
1 x 12013.8154339171708.038.7463430
1 x 15015.1126389214608.040.1483790
1 x 18517.00.1444264708.042.0504310
1 x 24019.6762522343408.045.5535170
3 x 508.739113771508.070.6817470
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.