DeepSea® Marine Cable NEK 606 P110 (P17) BU; 0.6/1KV; Power and Control; Max. 300,00mm²; 1 to 44 conductors; MICA + XLPE – EPR / SHF2; Fire Resistant; +90°C

DeepSea® Marine Power and Control Cable – Fire Resistant SHF2 P110 (P17) BU 0.6/1KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK 606 P110: Maximum Safety and Superior Performance for Offshore and Marine ApplicationsDeveloped for the most demanding conditions, our NEK 606 P110 cable offers maximum protection in power, control, and lighting systems. Its robust construction and state-of-the-art materials guarantee fire resistance, low smoke emission, and the absence of halogens, ensuring operational continuity and the protection of human life and critical equipment on platforms and vessels.
  • Superior Fire Resistance: Constructed with mica tape and XLPE insulation, it maintains circuit integrity even under direct fire.
  • Safety first: Low smoke emission and zero halogen (LSZH), crucial for visibility and safety during evacuations.
  • Robust Construction: Stranded copper conductors and SHF2 outer sheath for maximum durability in harsh environments.
  • Wide Application: Ideal for control, power, and lighting systems that demand the highest standards of safety and reliability.
  • International Membership: Compliant with stringent NEK 606 and IEC standards, guaranteeing a world-class product.
PRODUCT DESIGN
  • Conductors: Tin-plated annealed stranded copper to IEC 60228 class 2 or class 5.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in Mica tape + EPR upon request.
  • Outer Sheath: Halogen-free thermosetting compound, SHF2. In BLACK.
  • Roadway Identification according to NEK TS 606 Standard:
  • One way: Light Gray.
  • Two options: Light Gray, Black.
  • Three colors: Light Gray, Black, Red.
  • Four colors: Light Gray, Black, Red, Blue.
  • Multiple lanes: All lanes are white or light gray, numbered sequentially.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Light Gray, Black.
  • Three-way + ground (4G): Green/Yellow, Light Gray, Black, Red.
  • Four-way + ground (5G): Green/Yellow, Light Gray, Black, Red, Blue.
DETAILS

Benefits

  • Fire resistance: Designed to maintain circuit integrity even under fire.
  • Low Smoke Emission: In case of fire, it produces little smoke, facilitating evacuation.
  • Halogen-free: It does not emit toxic or corrosive gases when exposed to fire.
  • Flame Retardant: It hinders the spread of fires, increasing safety.
  • Installation Flexibility: Flexible copper conductors (class 2 or 5) facilitate handling.
  • Robust Insulation: Composed of mica tape and XLPE, ensuring high performance.
  • Durable Coating: SHF2 cover resistant to harsh environments.
  • Wide Temperature Range: It operates safely in temperatures ranging from -20°C to +90°C.
  • Compliance with Standards: It meets stringent international standards such as NEK 606 and IEC.
  • Security in Critical Systems: Ideal for power circuits, controls, and emergency lighting.

Applications

  • Offshore Platforms: Oil and gas installations that require maximum safety.
  • Naval Industry: Used in ships, vessels and other maritime structures.
  • Control Systems: Power supply for control panels and equipment in critical areas.
  • Lighting Circuits: Ensures the operation of emergency lighting systems.
  • Energy Systems: Power distribution in locations with a high risk of fire.
  • Areas with High Traffic: Essential for safety in tunnels, subways, and buildings.
  • Petrochemical Industries: Where resistance to chemicals and fire is essential.
  • Emergency Equipment: Power supply for alarms, fire pumps and exhaust fans.
  • Industrial Automation: Connecting sensors and actuators in harsh environments.
  • Special Projects: A versatile solution for applications that demand high reliability and security.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeFire-resistant power and control cables for offshore and marine applications.
CórdobaP110 (formerly P17) BU 0.6/1 kV
Product Design
Conductor MaterialAnnealed tin-plated copper, class 2 or 5.
Insulation MaterialMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in mica tape + EPR upon request.
Exterior Roofing MaterialSHF2 thermosetting compound, halogen-free.
Cover ColorBlack.
Identification of the Core Groups
  • Roadway Identification according to NEK TS 606 Standard:
  • One way: Light Gray.
  • Two options: Light Gray, Black.
  • Three colors: Light Gray, Black, Red.
  • Four colors: Light Gray, Black, Red, Blue.
  • Multiple lanes: All lanes are white or light gray, numbered sequentially.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Light Gray, Black.
  • Three-way + ground (4G): Green/Yellow, Light Gray, Black, Red.
  • Four-way + ground (5G): Green/Yellow, Light Gray, Black, Red, Blue.
Electrical Parameters
Operating Voltage0.6 / 1 kV
Nominal Cross Section1.5 mm² to 300 mm²
Nominal Conductor Diameter1.6 mm to 21.9 mm
Maximum DC resistance at 20°C0.0607 Ω/km to 12.2 Ω/km
Short-Circuit Current (1s)210 A to 42930 A
Mechanical and Thermal Properties
Radius of Curvature8 x outside diameter (during installation); 6 x outside diameter (fixed installation)
Temperature Range-20 ° C to + 90 ° C
Product characteristics
Fire resistantYes
Flame RetardantYes
Low Smoke EmissionYes
Halogen-freeYes
Applicable Standards
IEC 60092-353Power cables for electrical installations on ships.
IEC 60092-360Insulation and sheathing materials for onboard and offshore cables.
IEC 60331-21Testing electrical cables under fire conditions - circuit integrity.
IEC 60332-1Testing of electrical cables under fire conditions - testing of a single conductor or insulated cable in a vertical position.
IEC 60332 3 22Test for vertical flame propagation of cables in vertically mounted bundles - Category A.
IEC 60754-1,2Testing of gases produced during the combustion of cable materials.
IEC 61034-2Measurement of the density of smoke from burning cables under defined conditions.
NEK 606:2016Cables for offshore and oil and gas installations.
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-section mm²)Nominal Conductor Diameter (mm)Nominal Insulation Thickness (mm)Nominal Sheath Thickness (mm)Nominal Total Diameter (mm)Nominal Weight (kg/km)Maximum DC Resistance @20°C (Ω/km)Direct Current @45°C 1 Conductor (A)Direct Current @45°C 2 Conductors (A)Direct Current @45°C 3&4 Conductors (A)Short-Circuit Current 1s (A)
1 x 1.51.61.01.06.46512.2232016210
1 x 2.52.11.01.06.8757.56302621360
1 x 42.61.01.07.4954.7403428570
1 x 63.21.01.07.91203.11524436860
1 x 1041.01.18.81701.847261501430
1 x 165.11.01.110.22401.169682672290
1 x 256.51.21.212.0360734127108893580
1 x 357.41.21.213.14555291571331105010
1 x 508.71.41.314.76003911961671377150
1 x 7010.31.41.416.68050.2724220616910020
1 x 9512.21.61.519.0109519529324920513590
1 x 12013.81.61.520.6134515433928823717170
1 x 15015.11.81.622.7163512638933127221460
1 x 18517.02.01.725.220700.144444431126470
1 x 24019.62.21.828.4265576252244436534340
1 x 30021.92.41.931.1333560760151142142930
2 x 1.51.61.01.110.315512.2232016210
2 x 2.52.11.01.211.01907.56302621360
2 x 42.61.01.212.32504.7403428570
2 x 63.21.01.313.43103.11524436860
2 x 1041.01.315.64451.847261501430
2 x 165.11.01.418.26351.169682672290
2 x 256.51.21.622.0970734127108893580
2 x 357.41.21.724.012155291571331105010
2 x 508.71.41.827.416153911961671377150
2 x 7010.31.41.932.623350.2724220616910020
2 x 9512.21.62.137.6315519529324920513590
3 x 1.51.61.01.210.918012.2232016210
3 x 2.52.11.01.211.92307.56302621360
3 x 42.61.01.213.12954.7403428570
3 x 63.21.01.314.23753.11524436860
3 x 1041.01.416.55501.847261501430
3 x 165.11.01.519.37951.169682672290
3 x 256.51.21.623.51220734127108893580
3 x 357.41.21.725.615455291571331105010
3 x 508.71.41.929.520753911961671377150
3 x 7010.31.42.033.227750.2724220616910020
3 x 9512.21.62.238.5380019529324920513590
4 x 1.51.61.01.212.122512.2232016210
4 x 2.52.11.01.213.02757.56302621360
4 x 42.61.01.314.53654.7403428570
4 x 63.21.01.415.84903.11524436860
4 x 1041.01.418.46951.847261501430
4 x 165.11.01.521.510051.169682672290
4 x 256.51.21.726.11550734127108893580
4 x 357.41.21.828.519705291571331105010
4 x 508.71.42.032.826453911961671377150
4 x 7010.31.42.236.935450.2724220616910020
4 x 9512.21.62.442.8485019529324920513590
5 x 1.51.61.01.314.326512.2N/AN/AN/A210
5 x 2.52.11.01.314.53407.56N/AN/AN/A360
6 x 1.51.61.01.315.630512.2N/AN/AN/A210
6 x 2.52.11.01.417.03957.56N/AN/AN/A360
7 x 1.51.61.01.315.632012.2N/AN/AN/A210
7 x 2.52.11.01.417.04207.56N/AN/AN/A360
8 x 1.51.61.01.418.442512.2N/AN/AN/A210
8 x 2.52.11.01.520.05357.56N/AN/AN/A360
9 x 1.51.61.01.519.944012.2N/AN/AN/A210
9 x 2.52.11.01.521.55607.56N/AN/AN/A360
10 x 1.51.61.01.520.249512.2N/AN/AN/A210
10 x 2.52.11.01.521.86207.56N/AN/AN/A360
12 x 1.51.61.01.520.953012.2N/AN/AN/A210
12 x 2.52.11.01.622.76807.56N/AN/AN/A360
14 x 1.51.61.01.621.963012.2N/AN/AN/A210
14 x 2.52.11.01.623.98107.56N/AN/AN/A360
16 x 1.51.61.01.623.369012.2N/AN/AN/A210
16 x 2.52.11.01.725.48957.56N/AN/AN/A360
19 x 1.51.61.01.624.679012.2N/AN/AN/A210
19 x 2.52.11.01.726.810007.56N/AN/AN/A360
20 x 1.51.61.01.726.188012.2N/AN/AN/A210
20 x 2.52.11.01.828.411407.56N/AN/AN/A360
23 x 1.51.61.01.828.4103012.2N/AN/AN/A210
23 x 2.52.11.01.930.913257.56N/AN/AN/A360
24 x 1.51.61.01.829.2103512.2N/AN/AN/A210
24 x 2.52.11.01.931.813407.56N/AN/AN/A360
27 x 1.51.61.01.829.9108012.2N/AN/AN/A210
27 x 2.52.11.01.932.513957.56N/AN/AN/A360
30 x 1.51.61.01.931.1125012.2N/AN/AN/A210
30 x 2.52.11.02.033.916207.56N/AN/AN/A360
33 x 1.51.61.01.932.3133512.2N/AN/AN/A210
33 x 2.52.11.02.035.217357.56N/AN/AN/A360
37 x 1.51.61.02.033.8144512.2N/AN/AN/A210
37 x 2.52.11.02.136.818657.56N/AN/AN/A360
44 x 1.51.61.02.238.4176512.2N/AN/AN/A210
44 x 2.52.11.02.341.822957.56N/AN/AN/A360
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.