DeepSea® Marine Cable NEK 606 P118 (P34) BFOU-HCF; 0.6/1KV; Power and Control; Armored; Max. 300,00mm²; 1 to 27 conductors; MICA + XLPE – HFEPR / HC-FIRE LSOH + MICA / SHF2 – SHF2 MUD; Fire Resistant; +90°C

DeepSea® Marine Power and Control Cable – Fire Resistant SHF2 P118 (P34) BFOU-HCF 0.6/1KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 "The exact total amount, applying the discounts for your volume bracket, will be automatically calculated in your cart."

BFOU-HCF Cable: Maximum Fire Resistance for Industrial SafetyDesigned for the most critical operations in harsh offshore and marine environments. This cable ensures that emergency systems remain operational during fires, guaranteeing the continued protection of life and property at your valuable facility.
  • Maximum Fire Safety: It maintains functionality during fires of 1100°C, essential for emergency systems.
  • Robust and Reliable Construction: Tinned copper shielding and double sheathing (SHF1/SHF2) ensure maximum mechanical protection.
  • Low Smoke and Zero Halogen: In case of fire, it does not emit toxic gases, preserving lives and sensitive equipment.
  • Rigorous International Certification: Compliant with the most stringent industry standards, including NEK 606 and IEC.
  • Ideal for Critical Systems: Perfect for power, control, and emergency lighting circuits that simply cannot fail.
PRODUCT DESIGN
  • Conductors: Annealed, compacted, and stranded tin-plated copper according to IEC 60228 class 2 or class 5.
  • Insulation: Mica tape + halogen-free XLPE/EPR.
  • Intermediate Layer (Bedding): Halogen-free compound.
  • Armor: Mesh of tinned copper wires according to IEC 60092-350.
  • External Coating 1: Halogen-free thermoset compound, SHF2.
  • Fire protection HC: Extruded thermoplastic compound for fire protection.
  • Tape: Overlaid fire-resistant tape.
  • External Coating 2: Flame-retardant, halogen-free thermoplastic compound, SHF1, in black.
DETAILS

Benefits

  • Maximum Fire Safety: Operational during hydrocarbon fires at 1100°C.
  • Halogen-free: Low emission of smoke and toxic gases, protecting lives.
  • Flame Retardant: Construction that prevents the spread of fire in facilities.
  • High Mechanical Protection: Armor with copper braid that resists impacts.
  • Wide Temperature Range: Reliable performance in environments from -20°C to +90°C.
  • Durability in Marine Environments: SHF1 and SHF2 coatings for maximum durability.
  • Electrical Reliability: Tin-plated copper conductors resistant to corrosion.
  • Circuit Integrity: Mica tape insulation to ensure continuity of power.
  • Optimized Installation: Flexible bending radius for secure, fixed installations.
  • International Compliance: Meets stringent NEK 606 and IEC standards for offshore use.

Applications

  • Oil and Gas Platforms: Essential circuits for power, control, and lighting.
  • Ships and Vessels: Power supply for emergency systems that operate during fire.
  • Floating Production Storage and Offloading (FPSO) Units: For critical onboard control and safety systems.
  • Naval and Offshore Industry: Fixed installations in environments with harsh conditions.
  • Emergency Lighting Systems: It ensures lighting for safe evacuation in case of fire.
  • Critical Equipment Control: Power supply for fire pumps and ventilation systems.
  • Essential Power Circuits: It maintains power to vital equipment during a crisis.
  • Refineries and Petrochemical Plants: Areas with a high risk of hydrocarbon fires.
  • Control and Distribution Panels: Secure connection for emergency automation.
  • Security and Alarm Systems: Alarm and communication circuits that cannot fail.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeFire-Resistant Power and Control Cables for Offshore and Marine Applications (NEK 606)
CórdobaP118 (Formerly P34) BFOU-HCF
Electrical Parameters
Operating Voltage0.6 / 1 kV
Maximum DC Resistance of the Conductor at 20°CRanges from 12.2 Ω/km (1.5mm²) to 0.0607 Ω/km (300mm²)
DC Capacity @45°C (1 Channel)Ranges from 23 A (1.5mm²) to 601 A (300mm²)
DC Capacity @45°C (2-Way)Ranges from 20 A (1.5mm²) to 511 A (300mm²)
DC Capacity @45°C (3 & 4 Wires)Ranges from 16 A (1.5mm²) to 421 A (300mm²)
Short-Circuit Current (1s)Ranges from 210 A (1.5mm²) to 42930 A (300mm²)
Product Design
Conductor MaterialAnnealed, tin-plated, compacted and braided copper
Driver ClassIEC 60228 class 2 or class 5
InsulationMica tape + halogen-free EPR/XLPE
Inner Cover (Bedding)Halogen-free compound
Armor/ShieldingBraided tinned copper wire
Fire Protection HCExtruded thermoplastic compound for fire protection.
Protective TapeFire-resistant overlapping tape
External Cover 1 (Sheath 1)Halogen-free thermosetting compound, SHF2
External Cover 2 (Sheath 2)Flame-retardant, halogen-free thermoplastic compound, SHF1
Cover ColorBlack
Product characteristics
Application AreaEmergency control, power, and lighting systems that need to operate during a hydrocarbon fire at 1100°C.
Minimum Radius of Curvature20 x External Diameter (during installation); 12 x External Diameter (fixed installation)
Temperature Range-20 ° C to + 90 ° C
Fire resistantYes
Flame retardantYes
Low Smoke EmissionYes
Halogen-freeYes
Applicable Standards
NEK 606:2016IEC 60092-353
IEC 60092-360IEC 60331-21
IEC 60332-1IEC 60332 3 22
IEC 60754-1,2IEC 61034-1,2
IEC 60228IEC 60092-350
DIMENSIONAL TABLE

 

Number of Lanes x Cross-Sectional Area (mm²)Nominal Insulation Thickness (mm)Nominal Diameter Over the Inner Cover (mm)Nominal Diameter Over the Outer Cover 1 (mm)Nominal Total Diameter (mm)Nominal Weight (kg/km)Nominal Conductor Diameter (mm)Maximum DC Resistance at 20°C (Ω/km)DC Capacity at 45°C 1 Channel (A)DC Capacity at 45°C 2-Way (A)DC Capacity at 45°C 3 and 4 Wires (A)Short-Circuit Current 1s (A)Operating Voltage (kV)
1 x 501.415.018.545.529008.70.39119616713771500.6/1
1 x 701.416.520.547.5330010.30.27242206169100200.6/1
1 x 951.618.523.050.5380012.20.195293249205135900.6/1
1 x 1201.620.525.052.5426013.80.154339288237171700.6/1
1 x 1501.823.027.054.5475015.10.126389331272214600.6/1
1 x 1852.025.029.557.5538017.00.1444444311264700.6/1
1 x 2402.228.032.566.0705019.60.0762522444365343400.6/1
1 x 3002.430.535.568.0800021.90.0607601511421429300.6/1
2 x 1.51.010.013.040.518901.612.22320162100.6/1
2 x 2.51.011.014.542.020802.17.563026213600.6/1
3 x 1.51.010.514.042.021401.612.22320162100.6/1
3 x 2.51.011.515.042.522002.17.563026213600.6/1
3 x 41.013.016.543.024002.64.74034285700.6/1
3 x 61.014.018.045.026003.23.115244368600.6/1
3 x 161.018.523.050.035005.11.1696826722900.6/1
3 x 351.225.029.557.548407.40.52915713311050100.6/1
3 x 701.433.039.072.0815010.30.27242206169100200.6/1
4 x 2.51.012.516.544.023002.17.563026213600.6/1
4 x 61.015.519.547.528703.23.115244368600.6/1
4 x 161.020.525.053.538305.11.1696826722900.6/1
7 x 1.51.014.017.544.525501.612.2N/AN/AN/A2100.6/1
12 x 1.51.018.522.550.031401.612.2N/AN/AN/A2100.6/1
27 x 1.51.026.531.064.550701.612.2N/AN/AN/A2100.6/1
7 x 2.51.015.019.046.027602.17.56N/AN/AN/A3600.6/1
12 x 2.51.020.524.552.035002.17.56N/AN/AN/A3600.6/1
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.