DeepSea® Marine Cable NEK 606 P108 (P15) UX; 0.6/1KV; Power and Control; Max. 300,00mm²; 1 conductor; SHF2; Flame Retardant; +90°C

DeepSea® Marine Power and Control Cable – Flame Retardant SHF2 P108 (P15) UX 0.6/1KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

DeepSea® NEK 606 Marine Cable: Safety and Performance at SeaDesigned for the harshest offshore conditions, this cable is the ideal solution for grounding and connection. It guarantees maximum performance and reliability, protecting your assets, equipment, and your team.
  • Maximum Fire Safety: Flame retardant, low smoke and zero halogen, essential for onboard safety.
  • Robust Construction: Tinned copper conductor and SHF2 sheathing resist corrosion in marine environments.
  • Performance in Extreme Conditions: It operates from -20°C to +90°C, ensuring a stable and reliable energy flow.
  • Quality with Global Certification: Approved according to NEK 606 and IEC standards for international acceptance.
  • Critical Application: Ideal for grounding systems, vital for the electrical safety of platforms and ships.
PRODUCT DESIGN
  • Conductors: Tin-plated and annealed stranded copper to IEC 60228 class 2 or class 5.
  • Coating: Halogen-free thermosetting compound, SHF2. Yellow/green.
DETAILS

Benefits

  • Fire Safety: Construction using flame-retardant materials, low smoke emission, and halogen-free.
  • High Durability: SHF2 coating, thermosetting and robust, ideal for marine and offshore environments.
  • Corrosion Resistance: Tinned copper conductors that ensure a longer lifespan in saline atmospheres.
  • Certified Reliability: Compliant with the stringent NEK 606 and IEC 60092-353 standards, ensuring performance.
  • Equipment Protection: Because it is halogen-free, it does not emit corrosive gases that can damage electronic components.
  • Wide Temperature Range: It operates safely in a temperature range of -20°C to +90°C.
  • Installation Flexibility: Twisted wires (class 2 or 5) that facilitate installation in locations with bends.
  • Clear Identification: The green and yellow coloring of the outer coating indicates its purpose for grounding and bonding.
  • Low Toxicity: Low smoke emission and the absence of halogens increase safety for human life in case of fire.
  • Safe Electrical Performance: Designed for an operating voltage of 0.6/1kV, offering an effective grounding connection.

Applications

  • General Ship Grounding: Used for the main grounding of structures and systems on vessels of all types.
  • Oil and Gas Platforms: Essential for grounding and equipotential bonding services in offshore installations.
  • Structural Connection (Bonding): It connects different metal parts of ships or platforms to prevent differences in electrical potential.
  • Shipyards and Port Structures: It is used for grounding cranes, docks, and other large equipment.
  • Floating Production Storage and Offloading (FPSO) Units: Ideal for grounding and bonding in floating production and storage systems.
  • Cathodic Protection Systems: Used in conjunction with systems to protect ship hulls and structures against corrosion.
  • Grounding of Electrical Equipment: Secure connection of electrical panels, motors and generators to the vessel's grounding system.
  • Offshore Wind Energy: Used for grounding wind turbines and substations installed at sea.
  • Military and Special Vessels: It ensures electrical safety on ships that demand the highest performance standards.
  • Maritime Telecommunications Systems: Used to ground communication and navigation equipment, protecting it against interference.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
CórdobaP108 (Formerly P15) UX
Product typeFire-resistant, low-smoke, halogen-free power and control cables for offshore and marine applications.
ApplicationsUsed for grounding and connection services.
Electrical Parameters
Operating Voltage0.6 / 1 kV
Maximum Conductor Resistance (DC at 20°C)It varies according to the cross-section (e.g., 1.84 Ω/km for 10 mm²; 0.0607 Ω/km for 300 mm²).
DC Capacity (@45°C, 1 core)Varies according to the cross-section (e.g., 72 A for 10 mm²; 601 A for 300 mm²)
Short-Circuit Current (1s)Varies according to the cross-section (e.g., 1430 A for 10 mm²; 42930 A for 300 mm²)
Product Design
Conductor MaterialTin-plated, annealed, and braided copper.
Driver ClassClass 2 or Class 5, according to IEC 60228.
Sheath Material (Lining)Halogen-free thermosetting compound, SHF2.
Cover ColorYellow/Green.
Nominal Insulation ThicknessIt varies according to the cross-section (e.g., 1.0 mm for 10 mm²; 2.4 mm for 300 mm²).
Nominal Conductor DiameterIt varies according to the cross-section (e.g., 4.0 mm for 10 mm²; 21.9 mm for 300 mm²).
Nominal Outside DiameterIt varies according to the cross-section (e.g., 6.6 mm for 10 mm²; 27.2 mm for 300 mm²).
Nominal WeightIt varies according to the cross-section (e.g., 125 kg/km for 10 mm²; 3060 kg/km for 300 mm²).
Mechanical and Thermal Characteristics
Minimum Radius of CurvatureDuring installation: 8 x Outer Diameter; Fixed installation: 6 x Outer Diameter.
Temperature Range-20 ° C to + 90 ° C.
Flame retardantYes.
Halogen-freeYes.
Low Smoke EmissionYes.
Applicable Standards
Design and ConstructionIEC 60092-353, NEK 606:2016
Sheath MaterialIEC 60092-360 (SHF2)
ConductorIEC 60228 (Class 2 or 5)
Flame RetardantIEC 60332-1, IEC 60332-3-22
Smoke EmissionIEC 61034-1,2
Halogen GasesIEC 60754-1,2
DIMENSIONAL TABLE

 

Construction (Number of cores x Cross-sectional area) (mm²)Nominal Conductor Diameter (mm)Nominal Insulation Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)Maximum DC Resistance @20°C (Ω/km)DC Capacity @45°C 1 Core (A)Short-Circuit Current 1s (A)Operating Voltage (KV)
1 x 1041.06.61251.847214300.6/1
1 x 165.11.07.71851.169622900.6/1
1 x 256.51.29.52900.73412735800.6/1
1 x 357.41.210.43800.52915750100.6/1
1 x 508.71.412.15100.39119671500.6/1
1 x 7010.31.413.67000.27242100200.6/1
1 x 9512.21.615.59500.195293135900.6/1
1 x 12013.81.617.512050.154339171700.6/1
1 x 15015.11.819.414700.126389214600.6/1
1 x 18517.02.021.718750.1444264700.6/1
1 x 24019.62.224.724200.0762522343400.6/1
1 x 30021.92.427.230600.0607601429300.6/1
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.