DeepSea® Marine Cable NEK 606 P115 TFOU-HCF; 8.7/15 (17.5) kV; Medium Voltage Power; Armored; Max. 300,00 mm²; 1 to 03 conductors; Mica + XLPE / LSOH / SHF2 / LSOH HC / SHF1; Fire Resistant; +90°C

DeepSea® Medium Voltage Marine Cable – Fire Resistant SHF2 P115 TFOU-HCF 8.7/15 (17.5) kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK606 Marine Cables: Maximum Security for Critical ApplicationsDesigned for the harshest offshore conditions, these cables are flame-retardant and halogen-free. They ensure that critical power and lighting systems remain operational during fires up to 1100°C.
  • Extreme Fire Resistance: It remains operational in hydrocarbon fires at 1100°C.
  • Safety for People and Equipment: Low smoke emission and free of toxic halogens.
  • Robust and Reliable Construction: Tinned copper shielding and special coatings for maximum durability.
  • Ideal for Critical Offshore Applications: Platforms, ships and maritime units.
  • Full Compliance with Standards: It meets the stringent NEK 606 and IEC standards, guaranteeing complete peace of mind.
PRODUCT DESIGN
  • Conductors: Annealed circular tinned stranded copper to IEC 60228 class 2 or class 5.
  • Conductor Screen: Semiconductor material.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire mesh.
  • Filler: Halogen-free compound.
  • Armor: Tin-plated copper wire mesh.
  • Outer Sheath 1: Halogen-free thermoset compound, SHF2, in red.
  • Fire protection HC: Extruded thermoplastic compound for fire protection.
  • Encapamento: Fiberglass tape applied over the existing layers.
  • Outer Sheath 2: Flame-retardant, halogen-free thermoplastic compound, SHF1, in red.
DETAILS

Benefits

  • Maximum Fire Safety: Fire-resistant, flame-retardant, and halogen-free construction.
  • Critical Operation Guaranteed: Designed to maintain functionality during hydrocarbon fires.
  • Low Smoke Emission: It increases safety and visibility for evacuation in emergencies.
  • Wide Temperature Range: Reliable performance in operating conditions from -20°C to +90°C.
  • Superior Mechanical Protection: Tin-plated copper braid armor for added robustness.
  • High Durability in Marine Conditions: SHF2 external coating to withstand harsh offshore environments.
  • Circuit Integrity: Ensures that essential power and control systems remain active during a fire.
  • Reliable Power Transmission: Ideal for medium voltage systems of 8.7/15kV.
  • Compliance with Rigorous Standards: Meets NEK 606 and IEC standards for marine applications.
  • Robust Construction: Multiple layers of protection, including XLPE insulation.

Applications

  • Oil and Gas Platforms: Power and control circuits in areas with fire risk.
  • Emergency Lighting Systems: Power supply for lighting in escape routes and assembly areas.
  • Emergency Control Equipment: Energy for panels and systems vital to plant safety.
  • Ships and Maritime Vessels: General electrical installations requiring high fire safety.
  • FPSO Units: Ideal for critical systems in floating production and storage units.
  • Fire Pump Supply: Safe power supply for fire suppression systems.
  • Critical Communication Systems: Ensures the operation of emergency communication equipment.
  • Refineries and Onshore Terminals: Applications where resistance to hydrocarbon fire is vital.
  • Drilling and Accommodation Modules: Power distribution and control in operational and residential areas.
  • Uninterruptible Power Supply (UPS) Systems: Connection for essential backup power supplies.
TECHNICAL DATA
General information
BrandInnovcable DeepSea®
Product typeMedium Voltage Fire Resistant Cables (P115 TFOU-HCF)
ApplicationUsed in emergency, control, power, and lighting systems that need to remain operational during a hydrocarbon fire at 1100°C.
Electrical Parameters
Operating Voltage8.7/15 (17.5) kV
Maximum DC Resistance @20°CIt varies according to the cross-section (Ex: 0.270 Ω/km for 70 mm²)
DC Capacity @45°C (1 Channel)Varies according to the cross-section (Ex: 242 A for 70 mm²)
DC Capacity @45°C (3-Way)Varies according to the cross-section (Ex: 169 A for 70 mm²)
Short-Circuit Current (1s)Varies according to the cross-section (Ex: 10020 A for 70 mm²)
Product Design
Conductor MaterialBraided, annealed and tinned copper, class 2 or 5, according to IEC 60228.
Driver's ScreenSemiconductor material.
InsulationMica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire braid.
BeddingHalogen-free compound.
ArmorBraid of tinned copper wire.
Internal Cover (Sheath 1)Halogen-free thermosetting compound (SHF2).
Fire Protection HCExtruded thermoplastic compound for fire protection.
Protective TapeOverlapping fiberglass tape.
External Cover (Sheath 2)Flame-retardant, halogen-free thermoplastic compound (SHF1).
Cover ColorRed.
Product characteristics
Temperature Range-20 ° C to + 90 ° C.
Minimum Radius of Bend (Installation)20 x Outer Diameter.
Minimum Radius of Curvature (Fixed)12 x Outer Diameter.
Flame retardantYes.
Fire resistantYes.
Halogen-freeYes.
Low smoke emissionYes.
Applicable Standards
NEK 606:2016IEC 60092-354
IEC 60092-360IEC 60331-21
IEC 60332-1IEC 60332 3 22
IEC 60754-1,2IEC 61034-1,2
IEC 60228 Class 2 or 5-
DIMENSIONAL TABLE

 

Option 1: Copy and Paste the Table

 

Construction (Number of conductors x Cross-sectional area))Nominal Conductor Diameter (mm)Maximum DC Resistance @20°C (Ω/km)Direct Current @45°C 1 Conductor (A)Direct Current @45°C 3 Conductors (A)Short-Circuit Current 1s (A)Operating Voltage (KV)Nominal Insulation Thickness (mm)Nominal Thickness of Outer Sheath 1 (mm)Nominal Diameter Over Sheath 1 (mm)Nominal Total Diameter (mm)Nominal Weight (kg/km)
1 x 7010.30.27242169100208.7/154.51.332.464.45410
1 x 9512.20.195293205135908.7/154.51.434.466.96090
1 x 12013.80.154339237171708.7/154.51.536.669.16585
1 x 15015.10.126389272214608.7/154.51.538.170.66910
1 x 18517.00.1444311264708.7/154.51.540.673.17640
1 x 24019.60.0762522365343408.7/154.51.643.476.48480
1 x 30021.90.0607601421429308.7/154.51.746.379.39590
3 x 50N/AN/AN/AN/AN/AN/A4.52.060.694.611745
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.