HydroCore® Marine Cable NEK 606 Water Blocked S13 BU(i); 250V; Instrumentation and Control; Individual Shielding; Max. 2,50mm²; 1 to 3 pairs/triads; MICA + HFEPR / SHF2 / PUR; Fire resistant; +90°C

HydroCore® Marine Instrumentation Cable – Fire Resistant PUR Water Blocked S13 BU(i) 250 V

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK 606 Offshore Cables: Maximum Safety for Critical SystemsDesigned for the harshest conditions in marine and offshore environments, this cable offers superior protection and reliable data transmission for instrumentation, communication, control, and alarm systems, ensuring the integrity and safety of your critical operations.
  • Fire Safety: Fire resistant, with low smoke emission and zero halogen.
  • Moisture Protection: Water shutoff for maximum reliability and to prevent failures.
  • Superior Durability: External polyurethane coating for maximum resistance in harsh environments.
  • Versatile Applications: Ideal for control, alarm, communication and instrumentation systems.
  • Certified Reliability: Compliant with NEK 606 and IEC standards for guaranteed performance.
PRODUCT DESIGN
  • Conductors: Circular, tinned, corrugated and stranded copper wire, class 5, according to IEC 60228. Class 2 available upon request.
  • Insulation: Mica tape + Halogen-free EPR (HFEPR) compound.
  • Pairing: Color-coded cores twisted together.
  • Individual Shielding: Each pair/trio is shielded by copper-based polyester tape in contact with a braided tinned copper drain wire.
  • Water Blocking Elements: Water blocking tape and wires to provide longitudinal watertightness.
  • Inner layer: Halogen-free thermosetting compound, SHF2.
  • Outer layer: Polyurethane to provide transverse water tightness.
DETAILS

Benefits

  • Fire Safety: Fire-resistant, flame-retardant construction with low smoke emission.
  • Moisture Protection: Water-blocking elements that ensure longitudinal and transverse watertightness.
  • Circuit Integrity: Mica tape insulation that maintains functionality even during a fire.
  • Halogen-free: Composed of an internal SHF2 coating, which does not emit toxic or corrosive gases.
  • High Durability: External coating made of polyurethane to withstand harsh marine environments.
  • Reliable Signal: Individual shielding per pair/trio with copper tape and drain wire, protecting against interference.
  • Superior Conductivity: Class 2 tinned copper conductors to ensure stable electrical connections.
  • Wide Temperature Range: Safe performance in operating temperatures ranging from -20°C to +90°C.
  • Compliance with Standards: Designed in accordance with the stringent offshore standards NEK 606 and IEC.
  • Mechanical Resistance: Robust materials that ensure the protection of internal conductors.

Applications

  • Instrumentation Systems: Connecting sensors and meters on oil and gas platforms.
  • Automation and Control: Used in process control systems on vessels and offshore installations.
  • Communication Networks: Data and signal transmission in onboard ship communication systems.
  • Alarm and Security Systems: Fire alarm circuits, gas and other emergency systems.
  • General Maritime Applications: Installation in marine environments that require secure and robust cables.
  • Control Panels: Linking commands and signaling in control rooms of ships and platforms.
  • Navigation Equipment: Providing power and data to critical equipment on deck.
  • Intrinsic Safety Systems: Version with blue inner sheath for classified areas with explosion risk.
  • Machinery Control: Power supply and control of motors and actuators in marine environments.
  • Critical Installations: Ideal for areas where safety and operational continuity are essential.
TECHNICAL DATA
General information
Product typeNEK606 cables for Offshore & Marine applications, with water blocking. HydroCore®
ApplicationsInstrumentation, communication, control and alarm systems.
Main FeaturesPartially water-blocked, fire-resistant, flame-retardant, low smoke emission, and halogen-free.
Electrical Parameters
Operating Voltage250 V
Maximum Conductor Resistance (at 20°C)0.75 mm²: 26.3 Ω/km
1.0 mm²: 19.3 Ω/km
1.5 mm²: 12.9 Ω/km
2.5 mm²: 8.02 Ω/km
Mutual Capacitance0.75 mm²: 85 nF/km
1.0 mm²: 95 nF/km
1.5 mm²: 100 nF/km
2.5 mm²: 110 nF/km
Nominal Inductance (at 1KHz)0.75 mm²: 0.731 mH/km
1.0 mm²: 0.691 mH/km
1.5 mm²: 0.673 mH/km
2.5 mm²: 0.629 mH/km
Maximum L/N Ratio (at 1kHz)0.75 mm²: 20 μH/Ω
1.0 mm²: 25 μH/Ω
1.5 mm²: 35 μH/Ω
2.5 mm²: 55 μH/Ω
Product Design (Construction)
Conductor MaterialTinned, stranded, corrugated copper wire, circular, class 5 according to IEC 60228. Class 2 available upon request.
InsulationMica tape + Halogen-free EPR compound (HFEPR).
Formation of Pairs/TriosLanes with color-coded paths, fans together.
Individual ProtectionEach pair/trio is shielded with copper-based polyester tape in contact with a tinned copper drain wire, which is also wrapped in polyester tape.
FillWater-blocking fillers, if necessary.
Water Blocking ElementsWater-blocking tape and wires for longitudinal sealing.
Inner LayerHalogen-free thermosetting compound (SHF2), gray color (or blue for intrinsically safe systems).
Outer CoverPolyurethane (PUR) for cross-tight sealing. PE is optional, but does not meet the low smoke emission standard.
Mechanical and Thermal Properties
Minimum Radius of Curvature8 x External Diameter (during installation); 6 x External Diameter (fixed installation).
Operating Temperature Range-20 ° C to + 90 ° C.
Performance in Case of Fire
Circuit IntegrityIEC 60331-21
Flame RetardantIEC 60332-1
Reduced Fire SpreadIEC 60332 3 22
Halogen-freeIEC 60754-1
Low Corrosivity of GasesIEC 60754-2
Low Smoke EmissionIEC 61034-1, IEC 61034-2
Other features
Water tightness (transverse and longitudinal)Yes, as per VG 95218 part 29.
Dimensions and Weight (Examples)
NotaDimensions and weight vary significantly based on cable construction (number of pairs/triples and cross-sectional area). Consult the documentation for specific values.
Construction 1x2x0.75 mm²Nominal Outer Diameter: 10.2±2 mm; Nominal Weight: 110 kg/km.
Construction 12x2x0.75 mm²Nominal Outer Diameter: 23.1±2 mm; Nominal Weight: 740 kg/km.
Construction 1x2x1.5 mm²Nominal Outer Diameter: 11.6±2 mm; Nominal Weight: 163 kg/km.
Construction 24x3x1.5 mm²Nominal Outer Diameter: 43.7±2 mm; Nominal Weight: 2998 kg/km.
Applicable Standards
General StandardNEK 606
Cable ConstructionIEC 60092-376, IEC 60092-360
DriversIEC 60228 Class 2
Cover MaterialsIEC 60092-360 (SHF2)
Fire and Emission TestsIEC 60331-21, IEC 60332-1, IEC 60332-3-22, IEC 60754-1/2, IEC 61034-1/2
watertightnessVG 95218 part 29
DIMENSIONAL TABLE

 

Construction (Elements x Paths x Section mm2)Nominal Insulation Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
Cross-sectional area: 0.75 mm²
1x2x0.750.61.01.010.2±2 110
2x2x0.750.61.21.012.5±2 215
4x2x0.750.61.21.015.2±2 305
7x2x0.750.61.41.018.0±2 467
8x2x0.750.61.41.019.3±2 520
12x2x0.750.61.61.023.1±2 740
16x2x0.750.61.71.025.5±2 961
19x2x0.750.61.81.026.8±2 1087
24x2x0.750.61.91.030.6±2 1386
32x2x0.750.62.01.033.7±2 1754
1x3x0.750.61.01.010.6±2 126
2x3x0.750.61.21.014.0±2 215
3x3x0.750.61.21.015.8±2 315
4x3x0.750.61.31.017.1±2 383
7x3x0.750.61.51.020.3±2 588
8x3x0.750.61.51.021.5±2 683
12x3x0.750.61.71.026.4±2 961
16x3x0.750.61.81.029.3±2 1244
19x3x0.750.61.91.031.0±2 1428
24x3x0.750.62.11.035.7±2 1838
Cross-sectional area: 1.0 mm²
1x2x1.00.61.01.010.6±2 131
2x2x1.00.61.21.013.1±2 252
4x2x1.00.61.31.016.0±2 362
7x2x1.00.61.51.018.9±2 551
8x2x1.00.61.51.020.5±2 630
12x2x1.00.61.61.024.3 + 2882
16x2x1.00.61.61.026.9±2 1150
19x2x1.00.61.81.028.5±2 1318
24x2x1.00.61.91.032.5±2 1685
32x2x1.00.62.01.035.8±2 2132
1x3x1.00.61.01.011.1±2 147
3x3x1.00.61.31.016.7±2 378
4x3x1.00.61.31.018.1±2 462
7x3x1.00.61.61.021.7±2 730
12x3x1.00.61.71.028.0±2 1171
16x3x1.00.61.81.031.2±2 1528
19x3x1.00.61.91.033.0±2 1759
24x3x1.00.62.11.038.1±2 2252
Cross-sectional area: 1.5 mm²
1x2x1.50.71.01.011.6±2 163
2x2x1.50.71.31.014.6±2 326
4x2x1.50.71.41.018.1±2 473
7x2x1.50.71.61.021.4±2 725
8x2x1.50.71.61.023.3±2 819
12x2x1.50.71.71.027.7±2 1155
16x2x1.50.71.91.030.9±2 1523
19x2x1.50.72.01.032.5±2 1727
24x2x1.50.72.21.037.3±2 2221
32x2x1.50.72.31.041.1±2 2814
1x3x1.50.71.11.012.1±2 184
2x3x1.50.71.31.016.5±2 336
3x3x1.50.71.31.018.8±2 494
4x3x1.50.71.41.020.4±2 609
7x3x1.50.71.71.024.6±2 956
8x3x1.50.71.71.025.5±2 1082
12x3x1.50.71.91.032.0±2 1549
16x3x1.50.72.01.035.6±2 2021
19x3x1.50.72.11.037.7±2 2321
24x3x1.50.72.41.043.7±2 2998
Cross-sectional area: 2.5 mm²
1x2x2.50.71.11.012.5±2 200
1x3x2.50.71.31.013.0±2 231
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.