HydroCore® Marine Cable NEK 606 Water Blocked S3 or S3/S7 BFOU(i); 250V; Instrumentation and Control; Individual Shielding; Armored; Max. 2,50mm²; 1 to 37 pairs/trio; MICA + HFEPR / SHF2 – SHF MUD / PUR; Fire resistant; +90°C

HydroCore® Marine Instrumentation Cable – Fire Resistant PUR Water Blocked S3 or S3/S7 BFOU(i) 250V

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 "The exact total amount, applying the discounts for your volume bracket, will be automatically calculated in your cart."

NEK 606 Offshore Cables: Total Protection for Critical Marine SystemsDeveloped for the most extreme conditions in offshore environments and on vessels. This cable features a waterproof, fire-resistant, and mud-resistant construction, ensuring maximum safety and integrity for control, alarm, and communication systems in harsh environments.
  • High Fire Safety: Flame retardant, halogen-free, and low-smoke to protect lives and equipment.
  • Double Moisture Blocking: Longitudinal and transverse protection that prevents water infiltration, guaranteeing a longer lifespan.
  • Mechanical and Mud Resistance: Copper armor and cladding that withstand the most aggressive and corrosive environments.
  • Clear and Interference-Free Signal: Effective shielding that ensures data accuracy for control and instrumentation.
  • Operation in Extreme Climates: Stable and guaranteed performance at operating temperatures between -20°C and +90°C.
PRODUCT DESIGN
  • Conductors: Tin-plated and annealed circular braided copper wire
  • Conductor class: According to IEC 60228 standard, class 5. Class 2 available upon request.
  • Insulation: Mica tape + halogen-free EPR (ethylene-propylene rubber) compound
  • Settling: Halogen-free compound
  • Armor: Braid of tinned copper wire
  • Inner coating: Halogen-free thermosetting compound, SHF2
  • Outer layer: Polyurethane
DETAILS

Benefits

  • Fire Safety: Fire resistant, flame retardant and halogen free.
  • Low Smoke Emission: It ensures greater visibility in case of fire, facilitating evacuations.
  • Water Resistance: Construction with partial water blocking for protection in humid environments.
  • Mechanical Protection: Tinned copper mesh armor protects against impacts and damage.
  • Superior Durability: External polyurethane coating for resistance to harsh environments.
  • Mud Resistance: Designed to withstand the harsh conditions of offshore drilling.
  • Reliable Signal: Individual shielding per pair/trio prevents electromagnetic interference.
  • Wide Temperature Range: Operates safely in temperatures from -20°C to +90°C.
  • Circuit Integrity: It maintains the operation of systems even under fire conditions.
  • Secure Installation: Materials that do not emit toxic or corrosive gases when burned.

Applications

  • Offshore Platforms: Instrumentation, control and alarm systems in oil and gas units.
  • Ships and Vessels: Communication and control networks in marine environments.
  • Alarm Systems: Fire detection circuits and onboard safety systems.
  • Automation Control: Connecting sensors and actuators in automated processes.
  • Drilling Equipment: Electrical installations in areas with high exposure to mud and abrasion.
  • Naval Industry: For control and communication wiring in shipyards and commercial vessels.
  • Instrumentation Systems: Transmission of precise signals to measuring equipment.
  • Control Panels: Connecting control panels to equipment in critical areas.
  • Internal communication: Telephony and data systems on vessels and platforms.
  • Emergency Circuits: Applications that require functional integrity during a fire.
TECHNICAL DATA
General information
Product typeFire-resistant, water-blocking, low-smoke, halogen-free, and mud-resistant cables for instrumentation, communication, control, and alarm systems.
CórdobaWater Blocked S3 or S3/S7 BFOU(i) 250V
ApplicationsUsed for instrumentation, communication, control and alarm systems in offshore and marine installations.
Cable Construction
DriversTinned annealed copper wire, circular strand, class 5 according to IEC 60228. Class 2 available upon request.
InsulationMica tape + halogen-free EPR compound.
Formation of Pairs/TriosTwisted color-coded lanes joined together.
Individual ProtectionEach pair/suit is shielded with copper-based polyester tape in contact with a tinned copper drain wire.
FillingFill with water-blocking seals, if necessary.
Interior BeddingHalogen-free compound. PETP tape can be applied over the coating if needed.
ArmorBraid of tinned copper wire.
Water Blocking ElementsTape and cords to block water and ensure longitudinal watertightness.
Inner SheathType S3: Halogen-free thermosetting compound, SHF2.
Type S3/S7: Halogen-free, mud-resistant thermosetting compound (MUD), SHF MUD, in gray (or blue for intrinsic safety).
External CoverPolyurethane (PUR) for watertightness across the surface. PE is optional, but does not meet the low smoke emission standard.
Electrical Parameters
Operating Voltage250 V
Maximum Conductor Resistance (at 20°C)0.75 mm²: 26.3 Ω/km
1.0 mm²: 19.3 Ω/km
1.5 mm²: 12.9 Ω/km
2.5 mm²: 8.02 Ω/km
Mutual Capacitance0.75 mm²: 85 nF/km
1.0 mm²: 95 nF/km
1.5 mm²: 100 nF/km
2.5 mm²: 110 nF/km
Nominal Inductance (at 1KHz)0.75 mm²: 0.731 MH/km
1.0 mm²: 0.691 MH/km
1.5 mm²: 0.673 MH/km
2.5 mm²: 0.629 MH/km
Maximum L/R Ratio (at 1kHz)0.75 mm²: 20 µH/Ω
1.0 mm²: 25 µH/Ω
1.5 mm²: 35 µH/Ω
2.5 mm²: 55 µH/Ω
Mechanical and Thermal Properties
Minimum Radius of CurvatureDuring installation: 8 x Outer Diameter
Fixed installation: 6 x External Diameter
Temperature Range-20 ° C to + 90 ° C
Performance Characteristics
Fire Resistance (Circuit Integrity)IEC 60331-21
Flame RetardantIEC 60332-1
Reduced Fire SpreadIEC 60332 3 22
Halogen-freeIEC 60754-1
Low Corrosivity (Gases)IEC 60754-2
Low Smoke EmissionIEC 61034-1 & 2
Water tightnessVG 95218-29
Mud Resistance (MUD)Yes, for the S3/S7 type.
Applicable Standards
Main StandardsNEK 606:2004, IEC 60092-376, IEC 60092-360, IEC 60092-359, IEC 60092-351
Testing StandardsIEC 60228, IEC 60331, IEC 60332, IEC 60754, IEC 61034, VG 95218-29

 

DIMENSIONAL TABLE

 

ConstructionNominal Insulation Thickness (mm)Nominal Sheath Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
Cross-sectional area: 0.75 mm
1x2x0.750.61.11.21.014.1±2 236
2x2x0.750.61.11.31.018.7±2 425
3x2x0.750.61.11.41.019.5±2 567
4x2x0.750.61.11.41.020.6±2 641
5x2x0.750.61.11.51.022.2 + 2740
6x2x0.750.61.11.51.023.7±2 845
7x2x0.750.61.11.51.023.7±2 872
8x2x0.750.61.11.61.025.6±2 950
9x2x0.750.61.11.71.027.1±2 1050
10x2x0.750.61.11.71.028.2±2 1082
12x2x0.750.61.11.71.028.8±2 1202
14x2x0.750.61.11.81.030.2±2 1265
15x2x0.750.61.11.81.032.0±2 1370
16x2x0.750.61.11.91.032.6±2 1486
18x2x0.750.61.11.91.034.1±2 1549
19x2x0.750.61.21.91.034.7±2 1654
20x2x0.750.61.22.01.036.1±2 1785
21x2x0.750.61.22.01.037.0±2 1853
23x2x0.750.61.22.01.037.5±2 1990
24x2x0.750.61.22.11.039.7±2 2079
27x2x0.750.61.22.21.040.7±2 2273
30x2x0.750.61.22.21.041.9±2 2452
33x2x0.750.61.22.31.043.5±2 2662
37x2x0.750.61.22.31.044.7±2 2861
1x3x0.750.61.11.11.013.9±2 257
2x3x0.750.61.11.41.017.5±2 441
3x3x0.750.61.11.41.020.4±2 609
4x3x0.750.61.11.41.021.7±2 709
7x3x0.750.61.11.61.025.6±2 1008
8x3x0.750.61.11.71.027.0±2 1029
12x3x0.750.61.31.81.031.6±2 1507
16x3x0.750.61.41.91.034.6±2 1859
19x3x0.750.61.42.11.036.4±2 2084
24x3x0.750.61.82.21.041.6±2 2709
Cross-sectional area: 1.0 mm
1x2x1.00.61.11.21.014.5±2 257
2x2x1.00.61.11.41.019.6±2 473
3x2x1.00.61.11.41.020.3±2 630
4x2x1.00.61.11.41.021.3±2 656
5x2x1.00.61.11.51.023.1±2 966
6x2x1.00.61.11.61.024.8±2 998
7x2x1.00.61.11.61.024.8±2 903
8x2x1.00.61.11.61.026.7±2 1034
9x2x1.00.61.11.71.028.3±2 1192
10x2x1.00.61.11.71.029.4±2 1229
12x2x1.00.61.11.81.030.3±2 1365
14x2x1.00.61.11.81.031.5±2 1449
15x2x1.00.61.11.91.033.6±2 1586
16x2x1.00.61.11.91.034.1±2 1701
18x2x1.00.61.22.01.036.2±2 1832
19x2x1.00.61.22.01.036.5±2 1922
20x2x1.00.61.22.11.038.0±2 2074
21x2x1.00.61.22.11.039.3±2 2242
23x2x1.00.61.22.11.039.9±2 2410
24x2x1.00.61.22.21.041.8±2 2452
27x2x1.00.61.22.21.042.6±2 2625
30x2x1.00.61.22.31.044.1±2 2856
33x2x1.00.61.22.31.045.6±2 3087
37x2x1.00.61.42.41.047.4 + 23392
1x3x1.00.61.11.21.014.6±2 289
2x3x1.00.61.11.41.020.8±2 672
3x3x1.00.61.11.51.021.3±2 698
4x3x1.00.61.11.51.022.9±2 814
5x3x1.00.61.11.61.024.8±2 1013
6x3x1.00.61.11.71.027.4±2 1192
7x3x1.00.61.11.71.027.4±2 1239
8x3x1.00.61.11.71.029.0 + 21334
9x3x1.00.61.11.81.030.9±2 1523
10x3x1.00.61.11.91.033.1±2 1528
12x3x1.00.61.11.91.034.0±2 1769
14x3x1.00.61.22.01.035.8±2 1911
15x3x1.00.61.22.01.036.8±2 2032
16x3x1.00.61.22.11.038.0±2 2210
18x3x1.00.61.22.11.040.1±2 2426
19x3x1.00.61.22.21.040.6±2 2473
20x3x1.00.61.22.21.041.6±2 2720
21x3x1.00.61.22.21.042.4 + 22819
23x3x1.00.61.22.31.044.0±2 3082
24x3x1.00.61.22.31.044.8±2 3302
27x3x1.00.61.42.41.047.3±2 3418
30x3x1.00.61.42.51.049.4±2 3743
32x3x1.00.61.42.51.050.6±2 3943
Cross-sectional area: 1.5 mm
1x2x1.50.71.11.21.015.5±2 310
2x2x1.50.71.11.41.021.2±2 572
3x2x1.50.71.11.51.022.2 + 2761
4x2x1.50.71.11.51.023.5±2 809
5x2x1.50.71.11.61.025.4±2 1024
6x2x1.50.71.11.71.027.4±2 1187
7x2x1.50.71.11.71.027.4±2 1229
8x2x1.50.71.11.71.029.5±2 1286
9x2x1.50.71.11.81.031.4±2 1475
10x2x1.50.71.11.91.032.9±2 1512
12x2x1.50.71.11.91.033.6±2 1764
14x2x1.50.71.22.01.035.6±2 1838
15x2x1.50.71.22.11.038.0±2 2006
16x2x1.50.71.22.11.038.9±2 2158
18x2x1.50.71.22.21.040.9±2 2373
19x2x1.50.71.22.21.041.3±2 2515
20x2x1.50.71.22.21.042.8±2 2667
21x2x1.50.71.22.31.044.1±2 2793
23x2x1.50.71.22.31.044.7±2 3008
24x2x1.50.71.42.41.047.2 + 23234
27x2x1.50.71.42.41.048.1±2 3313
30x2x1.50.71.42.51.049.8±2 3612
32x2x1.50.71.42.61.051.0±2 3869
33x2x1.50.71.42.61.051.7±2 3927
37x2x1.50.71.42.61.053.2 + 24242
1x3x1.50.71.11.31.015.6±2 341
2x3x1.50.71.11.51.020.5±2 588
3x3x1.50.71.11.51.023.4±2 840
4x3x1.50.71.11.61.025.7±2 1024
5x3x1.50.71.11.71.027.4±2 1255
6x3x1.50.71.11.81.030.3±2 1475
7x3x1.50.71.11.81.030.3±2 1544
8x3x1.50.71.11.81.032.2±2 1664
9x3x1.50.71.21.91.034.6±2 1927
10x3x1.50.71.22.01.037.1±2 2032
12x3x1.50.71.22.11.038.8±2 2221
14x3x1.50.71.22.11.040.3±2 2478
15x3x1.50.71.22.21.041.7±2 2657
16x3x1.50.71.22.21.042.8±2 2914
18x3x1.50.71.22.31.044.9 + 23050
19x3x1.50.71.22.31.045.3±2 3360
20x3x1.50.71.42.41.046.9±2 3470
21x3x1.50.71.42.41.047.8±2 3602
23x3x1.50.71.42.51.049.7±2 3943
24x3x1.50.71.42.51.050.6±2 4121
27x3x1.50.71.42.61.053.1±2 4321
30x3x1.50.71.42.71.055.5±2 4736
32x3x1.50.71.62.81.057.5±2 5093
Cross-sectional area: 2.5 mm
1x2x2.50.71.11.31.016.0±2 357
2x2x2.50.71.11.51.020.5±2 588
3x2x2.50.71.11.51.023.6±2 908
4x2x2.50.71.11.61.025.2±2 1061
5x2x2.50.71.11.71.027.3±2 1244
6x2x2.50.71.11.71.029.4±2 1439
7x2x2.50.71.11.71.029.4±2 1502
8x2x2.50.71.11.81.031.9±2 1638
9x2x2.50.71.11.91.033.9±2 1869
10x2x2.50.71.22.01.035.8±2 1864
12x2x2.50.71.22.01.036.6±2 2063
14x2x2.50.71.22.11.038.9±2 2389
15x2x2.50.71.22.21.041.5±2 2604
16x2x2.50.71.22.21.042.1±2 2720
18x2x2.50.71.22.31.044.3±2 2966
19x2x2.50.71.22.31.044.7±2 3077
20x2x2.50.71.42.41.046.8±2 3402
21x2x2.50.71.42.41.048.1±2 3544
23x2x2.50.71.42.51.048.9±2 3738
24x2x2.50.71.42.51.051.1±2 3843
27x2x2.50.71.42.61.052.3±2 4200
30x2x2.50.71.42.71.054.2±2 4589
33x2x2.50.71.42.71.056.1±2 4972
37x2x2.50.71.62.81.058.4±2 5486
1x3x2.50.71.11.21.016.5±2 399
2x3x2.50.71.11.61.024.5±2 998
3x3x2.50.71.11.61.025.4±2 1108
4x3x2.50.71.11.71.027.3±2 1313
5x3x2.50.71.11.71.029.4±2 1533
6x3x2.50.71.11.91.032.7±2 1822
7x3x2.50.71.11.91.032.7±2 1922
8x3x2.50.71.22.01.035.3±2 2126
9x3x2.50.71.22.01.037.4±2 2405
10x3x2.50.71.22.21.040.8±2 2525
12x3x2.50.71.22.21.042.0 + 22819
14x3x2.50.71.22.31.043.9±2 3150
15x3x2.50.71.22.31.045.1±2 3350
16x3x2.50.71.42.41.046.9±2 3591
18x3x2.50.71.42.51.049.2 + 23927
19x3x2.50.71.42.51.049.6±2 4079
20x3x2.50.71.42.51.050.9±2 4394
21x3x2.50.71.42.61.052.0±2 4589
23x3x2.50.71.42.71.054.1±2 4998
24x3x2.50.71.42.71.055.0±2 5024
27x3x2.50.71.62.81.058.2±2 5602
30x3x2.50.71.62.91.060.8±2 6148
32x3x2.50.71.63.01.062.6±2 6526
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.