HydroCore® Marine Cable NEK 606 Water Blocked S11 RU(i); 250 V; Instrumentation and Control; Individual Shielding; Max. 1,50 mm²; 1 to 37 pairs / trios / quads; HFEPR / SHF2 / PUR; Flame retardant; +90°C

HydroCore® Marine Instrumentation Cable – Flame Retardant PUR Water Blocked S11 RU(i) 250 V

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Offshore Cable NEK606 with Water Blocking for InstrumentationDeveloped for the most severe offshore conditions. This cable features water blocking technology to ensure your control, alarm, and communication systems operate with maximum reliability, protecting your critical data and operations.
  • Total Protection Against Water: Longitudinal and transverse water blocking ensures continuous operation even under extreme humidity.
  • Maximum Operational Safety: Halogen-free, low smoke emission, and flame retardant to protect lives and equipment.
  • Pure and Reliable Signal: Individual shielding per pair with copper tape and drain wire, eliminating interference and ensuring data accuracy.
  • Durability in Harsh Environments: Polyurethane coating and tinned copper conductors for maximum mechanical strength and flexibility.
  • Critical Applications Guaranteed: Ideal for instrumentation, communication, control and alarm systems that demand unwavering performance on platforms and ships.
PRODUCT DESIGN
  • Conductors: Stranded, annealed and tinned copper wire, circular, conforming to IEC 60228 class 5. Class 2 available upon request.
  • Insulation: Halogen-free EPR compound.
  • Individual Shielding: Each pair/trio/quad is shielded by copper-based polyester tape in contact with a tinned and braided copper drain wire.
  • Water Blocking Elements: Water blocking tape and cords to provide longitudinal watertightness.
  • Inner Sheath: Halogen-free thermosetting compound, SHF2.
  • Outer Sheath: Polyurethane to provide transverse water tightness.
  • Road Identification:
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

  • Court colors: Black, Light Blue, Brown, and Gray.

  • Outer sheath: Gray (for standard instrumentation) or Blue (for Intrinsically Safe - IS circuits). Other colors, such as Black for greater UV resistance, available upon request.
DETAILS

Benefits

  • Superior Water Protection: Construction with watertight sealing that ensures the integrity of systems in marine and humid environments.
  • High Operational Safety: Halogen-free, with low smoke emission and flame-retardant properties.
  • Resistance to Harsh Environments: External polyurethane coating that offers excellent watertightness and durability.
  • Signal Integrity: Individual shielding by pair/trio, effective against electromagnetic interference in critical systems.
  • Long Service Life: Tinned copper conductors that provide greater flexibility and superior corrosion resistance.
  • Enhanced Fire Safety: Low corrosiveness of emitted gases, protecting sensitive electronic equipment.
  • Thermal Versatility: Reliable operation over a wide temperature range, suitable for diverse environmental conditions.
  • Flexible Installation: Optimized bending radius that facilitates assembly even in locations with limited space.
  • Approved Reliability: Designed in accordance with the stringent NEK 606 and IEC standards for offshore applications.
  • Failure Prevention: Blocking elements that prevent the longitudinal spread of moisture along the cable.

Applications

  • Oil and Gas Platforms: Ideal for control and instrumentation systems in offshore environments.
  • Ships and Vessels: Used in communication, control and alarm networks on board different types of vessels.
  • Process Control Systems: Connecting sensors and actuators in coastal or maritime industrial plants.
  • Floating Production Storage and Offloading (FPSO) Units: Wiring for control systems in production, storage and transfer units.
  • Security and Alarm Systems: Circuits for fire and gas detection in critical marine installations.
  • Onboard Communication Networks: Infrastructure for data systems, telephony and intercoms on vessels.
  • Critical Instrumentation: Connection of pressure, temperature and flow meters in machine and control rooms.
  • Shipyards and Port Terminals: Control applications in cranes and other load handling equipment.
  • Drilling Equipment: Transmission of control and data signals to offshore exploration equipment.
  • Emergency Shutdown Systems: Wiring for critical circuits requiring maximum reliability and safety.
TECHNICAL DATA
General information
Product typeNEK606 offshore and marine cables with water blocking. HydroCore®
ApplicationsUnarmored cables, partially blocked against water, flame retardant, with low smoke emission and halogen-free, used for instrumentation, communication, control and alarm systems.
Electrical Parameters
Operating Voltage250 V
Maximum Conductor Resistance at 20°C0.75 mm²: 26.3 Ω/km; 1.0 mm²: 19.3 Ω/km; 1.5 mm²: 12.9 Ω/km; 2.5 mm²: 8.02 Ω/km
Mutual Capacitance0.75 mm²: 90 nF/km; 1.0 mm²: 100 nF/km; 1.5 mm²: 110 nF/km; 2.5 mm²: 120 nF/km
Nominal Inductance at 1kHz0.75 mm²: 0.686 mH/km; 1.0 mm²: 0.649 mH/km; 1.5 mm²: 0.637 mH/km; 2.5 mm²: 0.598 mH/km
Maximum L/R at 1kHz0.75 mm²: 20 µH/Ω; 1.0 mm²: 25 µH/Ω; 1.5 mm²: 35 µH/Ω; 2.5 mm²: 50 µH/Ω
Product Design
Conductor MaterialStranded, corrugated, and tinned copper wire, class 5 according to IEC 60228. Class 2 available upon request.
InsulationHalogen-free EPR (Ethylene Propylene Rubber) compound.
Road Identification
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

  • Court colors: Black, Light Blue, Brown, and Gray.

Individual ProtectionEach pair/trio is shielded with copper-based polyester tape in contact with a tinned copper drain wire, which is also wrapped with polyester tape.
FillWater-locking fillers, if needed.
Water Blocking ElementsTape and wires that block water to ensure longitudinal watertightness.
Inner LayerHalogen-free thermosetting compound, SHF2, in gray (blue for intrinsic safety).
External CoverPolyurethane for cross-tight sealing; PE is optional, but does not meet the low smoke emission standard.
Outer Cover ColorOuter sheath: Gray (for standard instrumentation) or Blue (for Intrinsically Safe - IS circuits). Other colors, such as Black for greater UV resistance, available upon request.
Product characteristics
Minimum Radius of Curvature8 x External Diameter (during installation); 6 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Flame retardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Halogen-freeYes, in accordance with IEC 60754-1.
Low Smoke EmissionYes, in accordance with IEC 61034-1,2.
Low CorrosivityYes, in accordance with IEC 60754-2.
Water tightnessYes, as per VG 95218-29.
Applicable Standards
NEK 606IEC 60092-351
IEC 60092-376IEC 60092-360
IEC 60092-359IEC 60332-1
IEC 60332 3 22IEC 60754-1,2
IEC 61034-1,2VG 95218 part 29
DIMENSIONAL TABLE

Table of Electrical Characteristics

Nominal Cross-Sectional Area (mm²)Nominal Conductor Diameter (mm)Maximum Resistance @20°C (Ω/km)Mutual Capacitance (nF/km)Nominal Inductance @1KHz (MH/km)Maximum L/N Ratio @1KHz (μH/Ω)Operating Voltage (V)
0.751.126.3900.68620250
1.01.319.31000.64925250
1.51.612.91100.63735250
2.52.08.021200.59850250

Table of Dimensions and Weight

Construction (Number of elements x Number of paths in the element x Cross-sectional area in mm²)Nominal Insulation Thickness (mm)Nominal Thickness of the Inner Layer (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1x2x0.750.61.01.09.6±2 100
2x2x0.750.61.11.011.7±2 189
4x2x0.750.61.21.014.1±2 268
7x2x0.750.61.31.016.4±2 399
8x2x0.750.61.31.017.6±2 446
12x2x0.750.61.51.021.0±2 641
16x2x0.750.61.51.023.0±2 824
19x2x0.750.61.61.024.4±2 940
24x2x0.750.61.71.027.6±2 1192
32x2x0.750.61.81.030.4±2 1512
1x3x0.750.61.01.010.0±2 116
2x3x0.750.61.21.013.0±2 189
3x3x0.750.61.21.014.7±2 278
4x3x0.750.61.21.015.8±2 341
7x3x0.750.61.41.018.7±2 525
8x3x0.750.61.41.020.0±2 567
12x3x0.750.61.61.024.2±2 856
16x3x0.750.61.61.026.7±2 1097
19x3x0.750.61.71.028.2 + 21265
24x3x0.750.61.91.032.5±2 1622
1x2x1.00.61.01.010.1±2 116
2x2x1.00.61.11.012.4±2 226
4x2x1.00.61.21.014.9±2 326
7x2x1.00.61.41.017.5±2 499
8x2x1.00.61.41.019.0±2 567
12x2x1.00.61.51.022.5±2 798
16x2x1.00.61.51.024.9±2 1045
19x2x1.00.61.71.026.1±2 1192
24x2x1.00.61.81.029.8±2 1523
32x2x1.00.61.91.032.8±2 1943
1x3x1.00.61.01.010.5±2 131
3x3x1.00.61.31.015.4±2 336
4x3x1.00.61.31.016.8±2 415
7x3x1.00.61.51.019.9±2 646
12x3x1.00.61.61.025.7±2 1040
16x3x1.00.61.71.028.5±2 1360
19x3x1.00.61.81.030.0±2 1549
24x3x1.00.62.01.034.6±2 1995
1x2x1.50.71.01.011.1±2 147
2x2x1.50.71.21.013.7±2 294
4x2x1.50.71.31.016.9±2 431
7x2x1.50.71.51.020.0±2 667
8x2x1.50.71.51.021.7±2 756
12x2x1.50.71.61.025.8±2 1066
16x2x1.50.71.61.028.6±2 1397
19x2x1.50.71.91.030.3±2 1601
24x2x1.50.72.01.034.6±2 2042
32x2x1.50.72.21.038.1±2 2599
1x3x1.50.71.01.011.5±2 168
2x3x1.50.71.31.016.0±2 299
3x3x1.50.71.31.017.5±2 446
4x3x1.50.71.31.019.0±2 551
7x3x1.50.71.61.022.9 + 2872
8x3x1.50.71.61.024.5 + 2945
12x3x1.50.71.81.029.6±2 1407
16x3x1.50.71.91.033.1±2 1859
19x3x1.50.72.01.034.8±2 2121
24x3x1.50.72.21.040.4±2 2741
1x2x2.50.71.01.011.8±2 184
1x3x2.50.71.21.012.4±2 215
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.