HydroCore® Marine Cable NEK 606 Water Blocked P19 or P19/P21 TFOU; 12/20KV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 3 conductors; XLPE / SHF2 – SHF MUD / PUR; Flame retardant; +90°C

HydroCore® Medium Voltage Marine Cable – Flame Retardant PUR Water Blocked P19 or P19/P21 TFOU 12/20KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK606 Offshore Cables: Secure Power in Extreme EnvironmentsDeveloped for the most demanding offshore conditions, these cables ensure the transmission of medium-voltage power. With water blocking, mud resistance, and halogen-free construction, they guarantee maximum performance and safety in critical installations.
  • Superior Water Protection: Longitudinal and transverse water barrier that prevents moisture-related failures.
  • Fire Safety: Flame retardant, low smoke emission and completely halogen-free.
  • Resistance to Hostile Environments: It operates from -20°C to +90°C and has a special mud-resistant coating (MUD).
  • Guaranteed Electrical Performance: Stable and reliable power transmission for medium voltage applications.
  • Global Quality Standard: Designed for fixed installations, meeting the stringent NEK 606 and IEC standards.
PRODUCT DESIGN
  • Conductors: Circular tin-plated braided copper wire to IEC 60228 class 5. Class 2 available upon request.
  • Conductor Screen: Semiconductor material.
  • Insulation: Halogen-free XLPE (TFOU) (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire braid.
  • Filling: Water-blocking fillers, if necessary.
  • Coating: Halogen-free compound, PETP wrapping tape will be applied over the coating, if necessary.
  • Armor: Tinned copper wire braid, PETP wrapping tape will be applied over the braid if necessary.
  • Water Blocking Elements: Water blocking tape and cords to provide longitudinal watertightness.
  • Inner Coating: Halogen-free thermosetting compound, SHF2 (for TYPE P2), or halogen-free mud-resistant thermosetting compound, SHF MUD (for TYPE P2/P9), colored red.
  • Outer Sheath: Polyurethane to provide transverse water tightness; PE is optional but does not meet the low smoke standard.
DETAILS

Benefits

  • Moisture Protection: Construction with partial water blocking for safe installations.
  • High Operational Safety: Flame-retardant material with low smoke emission and halogen-free.
  • Resistance to Harsh Environments: Mud-resistant outer coating, ideal for offshore conditions.
  • Operation in Extreme Conditions: Wide operating temperature range, from -20°C to +90°C.
  • Superior Durability: Tinned copper conductors and robust sheathing for long service life.
  • Enhanced Security: Low emission of corrosive gases in case of fire, protecting equipment.
  • Strict Compliance: Meets NEK 606 standards and multiple IEC standards for marine use.
  • Reliable Installation: Designed specifically for fixed medium-voltage power installations.
  • Failure Prevention: Elements that ensure longitudinal and transverse watertightness.
  • Structural Integrity: Composed of multiple layers of protection, including copper screens and braids.

Applications

  • Oil and Gas Platforms: Power supply and control systems in offshore units.
  • Ships and Maritime Vessels: Medium voltage power distribution in fixed onboard installations.
  • Floating Production Storage and Offloading (FPSO) Units: Electrical circuits for production, storage and transfer units.
  • Drilling Probes: Applications in areas with drilling mud and humid environments.
  • Naval Industry: Installation in shipyards and on vessels during construction or repair.
  • Port Terminals: Power supply for cranes, gantries, and other large equipment.
  • Coastal Energy Systems: Electrical infrastructure in coastal installations exposed to marine environments.
  • Renewable Energy Projects: Connections in offshore wind farms and other marine energy installations.
  • Petrochemical Industry: Fixed installations in refineries and plants located in coastal areas.
  • Severe Industrial Applications: Locations that require high resistance to flame, moisture, and mud.
TECHNICAL DATA
General information
Product typeOffshore & Marine Cables NEK606 with Water Blocking P19 or P19/P21 TFOU 12/20KV and P20 or P20/P22 TFOU 18/30(36) kV. HydroCore®
ApplicationsThese cables are partially waterproof, flame retardant, low smoke emission, halogen-free and mud resistant, used for fixed medium voltage power installations.
Electrical Parameters
Operating Voltage12/20 kV or 18/30(36) kV.
Maximum DC resistance at 20°CIt varies from 1,16 Ω/km (for 16 mm²) to 0,0607 Ω/km (for 300 mm²).
DC Capacity at 45°C (1 Core)It ranges from 96 A (for 16 mm²) to 601 A (for 300 mm²).
DC Capacity at 45°C (3 Cores)It ranges from 67 A (for 16 mm²) to 421 A (for 300 mm²).
Short-Circuit Current (1s)It ranges from 2290 A (for 16 mm²) to 42930 A (for 300 mm²).
Product Design
Conductor MaterialCircular tin-plated braided wire, class 2, according to IEC 60228.
Driver's ScreenSemiconductor material.
InsulationHalogen-free XLPE (TFOU) (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire mesh.
FillingFill with water-blocking seals, if necessary.
Settlement (Bedding)Halogen-free compound. PETP wrapping tape will be applied over the installation, if necessary.
ArmorTin-plated copper wire mesh. PETP wrapping tape will be applied over the mesh, if necessary.
Water Blocking ElementsTape and wires that block water to provide longitudinal watertightness.
Inner LayerHalogen-free thermoset compound, SHF2 (for TYPE P19), or halogen-free mud-resistant thermoset compound, SHF MUD (for TYPE P19/P21), in red.
External CoverPolyurethane is used to provide transverse airtightness; PE is optional, but does not meet the low smoke emission standard.
Cable FormatRound
Product characteristics
Radius of Curvature15 x External Diameter (during installation); 9 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Flame RetardantCompliant with IEC 60332-1 and IEC 60332-3-22 (reduced fire spread).
Halogen-freeYes, in accordance with IEC 60754-1.
Low CorrosivityYes, in accordance with IEC 60754-2.
Low Smoke EmissionYes, in accordance with IEC 61034-1 & 2.
Mud ResistantYes (for TYPE P19/P21).
Water tightnessYes, longitudinal and transverse watertightness, as per VG 95218 part 29.
Dimensions and Weight
Cross SectionAvailable in sizes from 1x16 mm² to 1x300 mm² and from 3x16 mm² to 3x300 mm².
Nominal Outside DiameterIt varies from 30,0 mm (for 1x16 mm²) to 105,1 mm (for 3x300 mm²), with a tolerance of ±2 mm.
Nominal WeightIt varies from 1260 kg/km (for 1x16 mm²) to 18050 kg/km (for 3x300 mm²).
Applicable Standards
NEK 606IEC 60092-351
IEC 60092-354IEC 60092-359
IEC 60092-360IEC 60228 Class 2
IEC 60332-1IEC 60332 3 22
IEC 60754-1,2IEC 61034-1,2
VG 95218 part 29-
DIMENSIONAL TABLE
Construction (Number of cores x Cross-sectional area mm²)Nominal Conductor Diameter (mm)Maximum DC Resistance at 20°C (Ω/km)Direct Current at 45°C 1 Core (A)Direct Current at 45°C 3 Cores (A)Short-Circuit Current 1s (A)Operating Voltage (KV)Nominal Insulation Thickness (mm)Nominal Bed Thickness (mm)Nominal Thickness of Internal Cover (mm)Nominal Thickness of the External Cover (mm)Nominal Total Diameter (mm)Nominal Weight (kg/km)
1 x 165.21.169667229012/205.51.41.21.030.0±2 1260
1 x 256.573412789358012/205.51.51.21.234.0±2 1607
1 x 357.4529157110501012/205.51.81.31.234.7±2 1675
1 x 508.7391196137715012/205.51.81.41.236.2±2 1885
1 x 7010.30.272421691002012/205.51.91.41.237.0±2 2174
1 x 9512.21952932051359012/205.52.01.51.439.8±2 2594
1 x 12013.81543392371717012/205.52.01.51.441.6±2 2951
1 x 15015.11263892722146012/205.52.11.61.443.5±2 3407
1 x 18517.00.14443112647012/205.52.21.61.445.7±2 3953
1 x 24019.67625223653434012/205.52.31.71.649.0±2 4736
1 x 30021.96076014214293012/205.52.41.81.651.7±2 5581
3 x 165.21.169667229012/205.51.82.01.057.1±2 5198
3 x 256.573412789358012/205.51.92.01.264.6±2 5990
3 x 357.4529157110501012/205.52.92.11.265.0±2 6290
3 x 508.7391196137715012/205.53.02.21.267.8±2 7077
3 x 7010.30.272421691002012/205.53.12.31.271.5±2 8180
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.