HydroCore® Marine Cable NEK 606 Water Blocked P2 or P2/P9 TFOU; 3.6/6KV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 3 conductors; XLPE / SHF2 – SHF MUD / PUR; Flame retardant; +90°C

HydroCore® Medium Voltage Marine Cable – Flame Retardant PUR Water Blocked P2 or P2/P9 TFOU 3.6/6KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK 606 Offshore Cable: Safety and Performance for Critical ApplicationsDeveloped for fixed medium-voltage installations in the most challenging offshore environments. This cable features superior construction, guaranteeing maximum protection, continuous performance, and safety against the harsh elements of the sea, ensuring the integrity of your operation.
  • Maximum Fire Safety: Flame retardant, low smoke and halogen-free, protecting lives and critical equipment.
  • Total Water Blockage: Special tapes and fillers ensure a watertight seal, preventing moisture ingress and corrosion.
  • Robustness and High Durability: Polyurethane coating and SHF MUD compound, resistant to mud, abrasion and aggressive fluids.
  • Reliable Electrical Performance: Tinned copper conductors and XLPE insulation for stable and safe power transmission.
  • Versatility in Extreme Conditions: It operates stably in temperatures from -20°C to +90°C, ideal for various marine installations.
PRODUCT DESIGN
  • Conductors: Circular tin-plated braided copper wire to IEC 60228 class 5. Class 2 available upon request.
  • Conductor Screen: Semiconductor material.
  • Insulation: Halogen-free XLPE (TFOU) (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire braid.
  • Filling: Water-blocking fillers, if necessary.
  • Coating: Halogen-free compound, PETP wrapping tape will be applied over the coating, if necessary.
  • Armor: Tinned copper wire braid, PETP wrapping tape will be applied over the braid if necessary.
  • Water Blocking Elements: Water blocking tape and cords to provide longitudinal watertightness.
  • Inner Coating: Halogen-free thermosetting compound, SHF2 (for TYPE P2), or halogen-free mud-resistant thermosetting compound, SHF MUD (for TYPE P2/P9), colored red.
  • Outer Sheath: Polyurethane to provide transverse water tightness; PE is optional but does not meet the low smoke standard.
DETAILS

Benefits

  • Superior Water Protection: Longitudinal and transverse water blocking for maximum reliability.
  • Enhanced Fire Safety: Flame retardant, with low smoke emission and halogen-free.
  • High Chemical Resistance: Special compound in the inner lining resistant to mud and drilling oils.
  • Robust Offshore Construction: Designed to withstand the harsh conditions of marine environments.
  • High Durability: Tinned copper conductors and braid that prevent corrosion.
  • Stable Electrical Performance: XLPE insulation for medium voltage installations (3.6/6kV).
  • Compliance with Strict Standards: Certified according to NEK 606 and IEC standards for offshore use.
  • Effective Electromechanical Shielding: Protection with braided copper wire for greater integrity.
  • Wide Temperature Range: Safe operation within a temperature range of -20°C to +90°C.
  • Reliable Fixed Installation: Ensures integrity and safety in medium-voltage power circuits.

Applications

  • Oil and Gas Platforms: Power supply for drilling and production equipment.
  • Naval and Maritime Installations: Power distribution circuits in vessels and ships.
  • Drilling Probes: Ideal for fixed electrical installations in muddy areas.
  • Floating Production Storage and Offloading (FPSO) Units: Safe power distribution for process and accommodation modules.
  • Deck Equipment: Connecting machines and systems exposed to harsh marine environments.
  • Port Terminals: Power supply for cranes and other yard equipment.
  • Petrochemical Industry: Applications in coastal areas subject to high humidity and salinity conditions.
  • Medium Voltage Systems: General use in fixed industrial installations requiring high performance.
  • Offshore Renewable Energy: Connection in substations for wind farms and tidal energy plants.
  • Shipyards and Shipbuilding: Electrical infrastructure during ship construction and repair.
TECHNICAL DATA
General information
Product typeOffshore & Marine Cables NEK606 with Water Blocking (P2 or P2/P9 TFOU) HydroCore®
ApplicationsFor fixed medium-voltage power installations. They are partially sealed against water, flame retardant, low smoke emission, halogen-free and mud resistant.
Electrical Parameters
Operating Voltage3.6 / 6 kV
Maximum DC resistance at 20°CRanges from 1.16 Ω/km (16mm²) to 0.0286 Ω/km (630mm²)
DC Capacity at 45°C (1 Core)Ranges from 96 A (16mm²) to 890 A (630mm²)
DC Capacity at 45°C (3 Cores)Ranges from 67 A (16mm²) to 623 A (630mm²)
Short-Circuit Current (1s)Ranges from 2290 A (16mm²) to 90140 A (630mm²)
Product Design
Conductor MaterialTin-plated, braided and ringed copper, class 5 according to IEC 60228. Class 2 available upon request.
Driver's ScreenSemiconductor material.
InsulationHalogen-free XLPE (TFOU) (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire mesh.
FillingFill with water-blocking seals, if necessary.
Interior BeddingHalogen-free compound. PETP tape can be applied over the coating if needed.
ArmorTin-plated copper wire mesh. PETP tape can be applied over the mesh if needed.
Water Blocking ElementsWater-blocking tape and wires for longitudinal sealing.
Inner LayerHalogen-free thermoset compound, SHF2 (for TYPE P2), or halogen-free mud-resistant thermoset compound, SHF MUD (for TYPE P2/P9), in red.
External CoverPolyurethane for cross-tight sealing. PE is optional, but does not meet the low smoke emission standard.
Mechanical and Thermal Properties
Radius of Curvature15 x External Diameter (during installation); 9 x External Diameter (fixed installation)
Temperature Range-20 ° C to + 90 ° C
Ambient Temperature Correction FactorsFactor of 1.1 at 35°C, 1.0 at 45°C, down to 0.47 at 80°C
Applicable Standards
NEK 606IEC 60092-354
IEC 60092-360IEC 60332-1 (Flame retardant)
IEC 60332-3-22 (Reduced fire spread)IEC 60754-1,2 (Halogen-free, Low corrosivity)
IEC 61034-1,2 (Low smoke emission)VG 95218 part 29 (Leak tightness)
IEC 60228 class 2

Ambient Temperature Correction Factors

Ambient Temperature (°C)35404550556065707580
Classification Factor1.101.051.00.940.880.820.740.670.580.47
DIMENSIONAL TABLE
Construction (Number of Roads x Section mm²)Nominal Conductor Diameter (mm)Nominal Insulation Thickness (mm)Nominal Thickness of the Inner Layer (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)Maximum DC Resistance @20°C (Ω/km)DC Capacity @45°C (A)Short-Circuit Current 1s (A)Operating Voltage (KV)
1 via
1 x 165.12.51.41.11.024.8 2 ±8191.169622903.6/6
1 x 256.52.51.51.11.226.4 2 ±107173412735803.6/6
1 x 357.42.51.51.21.227.5 2 ±121352915750103.6/6
1 x 508.72.51.61.21.228.7 2 ±138639119671503.6/6
1 x 7010.32.51.61.31.230.6 2 ±16750.27242100203.6/6
1 x 9512.22.51.71.31.432.8 2 ±2000195293135903.6/6
1 x 12013.82.51.81.41.434.6 2 ±2347154339171703.6/6
1 x 15015.12.51.81.41.436.3 2 ±2678126389214603.6/6
1 x 18517.02.51.91.51.438.0 2 ±31660.1444264703.6/6
1 x 24019.62.62.01.51.642.0 2 ±3911762522343403.6/6
1 x 30021.92.82.11.61.645.5 2 ±4856607601429303.6/6
3 tracks
3 x 165.12.52.21.61.046.9 2 ±30771.166722903.6/6
3 x 256.52.52.31.71.247.8 2 ±35607348935803.6/6
3 x 357.42.52.41.81.250.0 2 ±401152911050103.6/6
3 x 508.72.52.51.91.253.3 2 ±472039113771503.6/6
3 x 7010.32.52.72.01.257.2 2 ±58640.27169100203.6/6
3 x 9512.22.52.82.11.461.7 2 ±7103195205135903.6/6
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.