HydroCore® Marine Cable NEK 606 Water Blocked P17 BU; 0.6/1KV; Power and Control; Max. 300,00mm²; 1 to 44 conductors; MICA + EPR / SHF2 / PUR; Fire Resistant; +90°C

HydroCore® Marine Power and Control Cable – Fire Resistant PUR Water Blocked P17 BU 0.6/1 kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

The Ultimate Solution in Offshore Cables for Safety and ReliabilityDesigned for the harshest conditions in marine and offshore environments, these cables ensure the continuity and protection of critical control, power, and lighting systems. Their robust and technologically advanced construction offers an impenetrable barrier against water, ensuring safe and uninterrupted operation.
  • Maximum Protection Against Water: Construction with partial water blocking, hydrophobic tapes and fillers that guarantee longitudinal and transverse watertightness.
  • Superior Fire Resistance: Equipped with mica tape and HFEPR insulation, it is fire-resistant and maintains circuit integrity under fire conditions.
  • Security in Focus: Halogen-free, with low smoke and corrosive gas emissions, as well as being flame retardant and reducing the spread of fire.
  • Robust and Durable Construction: Stranded copper conductors, with SHF2 inner sheathing and polyurethane outer sheathing for maximum mechanical protection.
  • Certified Performance: It meets stringent international standards such as NEK 606 and multiple IEC standards, ensuring full compliance and performance.
PRODUCT DESIGN
  • Conductors: Annealed tin-plated stranded copper to IEC 60228 class 5. Class 2 available upon request.
  • Insulation: Mica tape + halogen-free EPR (ethylene-propylene rubber).
  • Filling: Water-blocking fillers, if necessary.
  • Water Blocking Elements: Water blocking tape and wires to provide longitudinal watertightness.
  • Inner layer: Halogen-free thermosetting compound, SHF2.
  • Outer Cover: Polyurethane to provide transverse watertightness. In black.
  • Roadway Identification according to NEK TS 606 Standard:
  • One way: Light Gray.
  • Two options: Light Gray, Black.
  • Three colors: Light Gray, Black, Red.
  • Four colors: Light Gray, Black, Red, Blue.
  • Multiple lanes: All lanes are white or light gray, numbered sequentially.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Light Gray, Black.
  • Three-way + ground (4G): Green/Yellow, Light Gray, Black, Red.
  • Four-way + ground (5G): Green/Yellow, Light Gray, Black, Red, Blue.
DETAILS

Benefits

  • Water Protection: Construction partially sealed against water, with elements that guarantee longitudinal and transverse watertightness.
  • Maximum Fire Safety: Fire resistant, flame retardant and designed for reduced fire spread.
  • Personal and Equipment Safety: Halogen-free, with low smoke emission and low corrosiveness in case of fire.
  • Robust Construction: Braided copper conductors, mica tape and EPR insulation, and double sheaths for high durability.
  • High Thermal Performance: Reliable operation over a wide temperature range, from -20°C to +90°C.
  • Superior Resistance: The outer polyurethane sheath offers excellent protection in harsh environments.
  • Strict Compliance: Designed in accordance with the stringent NEK 606 standards and multiple IEC standards for offshore use.
  • Circuit Integrity: It maintains the functionality of electrical circuits even during exposure to fire.

Applications

  • Oil and Gas Platforms: Ideal for offshore installations that require maximum safety and reliability.
  • Naval and Maritime Industry: Application in ships, vessels and other maritime structures.
  • Energy Systems: Used for distributing electrical power in critical environments.
  • Control and Lighting Systems: Perfect for powering and controlling lighting and automation systems.
  • Drilling Probes: Durability and safety for operating drilling equipment.
  • Fixed Installations: Suitable for fixed electrical installations in harsh industrial environments.
  • Areas with High Security Requirements: Essential for locations where protecting life and equipment in case of fire is a priority.
  • Port Infrastructure: Reliability for electrical systems in ports and terminals.
TECHNICAL DATA

 

General information
Product typeOffshore and marine cables NEK606 with water blocking. HydroCore®
ApplicationsUsed in control, power, and lighting systems.
Electrical Parameters
Operating Voltage0.6 / 1 kV
Maximum DC Resistance @20°CIt varies according to the cross-sectional area of ​​the conductor (see data tables).
DC Capacity @45°CIt varies according to the cross-section and the number of lanes (see data tables).
Short-Circuit Current (1s)It varies according to the cross-sectional area of ​​the conductor (see data tables).
Temperature Correction FactorsClassification factors applicable to ambient temperatures from 35°C to 80°C.
Product Design (Construction)
Conductor MaterialAnnealed tin-plated copper, stranded, class 2, according to IEC 60228.
InsulationMica tape + halogen-free EPR (HFEPR).
FillWater-blocking fillers, if necessary.
Water Blocking ElementsWater-blocking tape and threads to ensure longitudinal watertightness.
Inner LayerHalogen-free thermosetting compound (SHF2).
Outer CoverPolyurethane (PUR) for transverse sealing, in black.
Identification of the Core Groups
  • Roadway Identification according to NEK TS 606 Standard:
  • One way: Light Gray.
  • Two options: Light Gray, Black.
  • Three colors: Light Gray, Black, Red.
  • Four colors: Light Gray, Black, Red, Blue.
  • Multiple lanes: All lanes are white or light gray, numbered sequentially.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Light Gray, Black.
  • Three-way + ground (4G): Green/Yellow, Light Gray, Black, Red.
  • Four-way + ground (5G): Green/Yellow, Light Gray, Black, Red, Blue.
Mechanical and Thermal Properties
Minimum Radius of Curvature8 x External Diameter (during installation); 6 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Fire Resistance (Circuit Integrity)Yes, in accordance with IEC 60331-21.
Flame RetardantYes, in accordance with IEC 60332-1.
Reduced Fire SpreadYes, in accordance with IEC 60332-3-22.
Halogen-freeYes, in accordance with IEC 60754-1.
Low Smoke EmissionYes, in accordance with IEC 61034-1 & 2.
Low Corrosivity of GasesYes, in accordance with IEC 60754-2.
Water tightnessYes, as per VG 95218-29.
Applicable Standards
Main StandardNEK 606:2004
Construction and DesignIEC 60092-351, IEC 60092-353, IEC 60092-359, IEC 60092-360
DriversIEC 60228 Class 2
Behavior in FireIEC 60331-21, IEC 60332-1, IEC 60332-3-22
Smoke and Gas EmissionIEC 60754-1, IEC 60754-2, IEC 61034-1&2
Water ResistanceVG 95218-29

Table of Electrical Characteristics

This table summarizes the main electrical parameters of cables by cross-section.

Nominal Cross-Sectional Area (mm²)Nominal Conductor Diameter (mm)Maximum DC Resistance at 20°C (Ω/km)DC Capacity at 45°C 1 Channel (A)DC Capacity at 45°C 2-Way (A)DC Capacity at 45°C 3 and 4 Wires (A)Short-Circuit Current 1s (A)Operating Voltage (KV)
1.51.612.22320162100.6/1
2.52.17.563026213600.6/1
42.64.74034285700.6/1
63.23.115244368600.6/1
1041.8472615014300.6/1
165.11.1696826722900.6/1
256.57341271088935800.6/1
357.452915713311050100.6/1
508.739119616713771500.6/1
7010.30.27242206169100200.6/1
9512.2195293249205135900.6/1
12013.8154339288237171700.6/1
15015.1126389331272214600.6/1
18517.00.1444444311264700.6/1
24019.6762522444365343400.6/1
30021.9607601511421429300.6/1

Table of Ambient Temperature Correction Factors

This table provides the factors for adjusting the current capacity based on ambient temperature.

Ambient Temperature (°C)Classification Factor
351.1
4001.05
451.0
500.94
550.88
600.82
650.74
700.67
750.58
800.470
DIMENSIONAL TABLE
Construction (Number of Roads x Cross-Section mm²)Nominal Insulation Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1 Way
1 x 1.51.01.01.08.4±2 68
1 x 2.51.01.01.08.8±2 79
1 x 41.01.01.09.4±2 100
1 x 61.01.01.09.9±2 126
1 x 101.01.11.010.8±2 179
1 x 161.01.11.012.2±2 252
1 x 251.21.21.214.4±2 378
1 x 351.21.21.215.5±2 478
1 x 501.41.31.217.1±2 630
1 x 701.41.41.219.0±2 845
1 x 951.61.51.421.8±2 1150
1 x 1201.61.51.423.4±2 1412
1 x 1501.81.61.425.5±2 1717
1 x 1852.01.71.428.0±2 2174
1 x 2402.21.81.631.6±2 2788
1 x 3002.41.91.634.3±2 3502
2 Ways
2 x 1.51.01.11.012.3±2 163
2 x 2.51.01.21.013.0±2 200
2 x 41.01.21.014.3±2 263
2 x 61.01.31.015.4±2 326
2 x 101.01.31.017.6±2 467
2 x 161.01.41.020.2±2 667
2 x 251.21.61.224.4±2 1019
2 x 351.21.71.226.4±2 1276
2 x 501.41.81.229.8±2 1696
2 x 701.41.91.235.0±2 2452
2 x 951.62.11.440.4±2 3313
3 Ways
3 x 1.51.01.21.012.9±2 189
3 x 2.51.01.21.013.9±2 242
3 x 41.01.21.015.1±2 310
3 x 61.01.31.016.2±2 394
3 x 101.01.41.018.5±2 578
3 x 161.01.51.021.3±2 835
3 x 251.21.61.225.9±2 1281
3 x 351.21.71.228.0±2 1622
3 x 501.41.91.231.9±2 2179
3 x 701.42.01.235.6±2 2914
3 x 951.62.21.441.3±2 3990
4 Ways
4 x 1.51.01.21.014.1±2 236
4 x 2.51.01.21.015.0±2 289
4 x 41.01.31.016.5±2 383
4 x 61.01.41.017.8±2 515
4 x 101.01.41.020.4±2 730
4 x 161.01.51.023.5±2 1055
4 x 251.21.71.228.5±2 1628
4 x 351.21.81.230.9±2 2069
4 x 501.42.01.235.2±2 2777
4 x 701.42.21.239.3±2 3722
4 x 951.62.41.445.6±2 5093
Multiple Pathways
5 x 1.51.01.31.016.3±2 278
5 x 2.51.01.31.016.5±2 357
6 x 1.51.01.31.017.6±2 320
6 x 2.51.01.41.019.0±2 415
7 x 1.51.01.31.017.6±2 336
7 x 2.51.01.41.019.0±2 441
8 x 1.51.01.41.020.4±2 446
8 x 2.51.01.51.022.0±2 562
9 x 1.51.01.51.021.9±2 462
9 x 2.51.01.51.023.5±2 588
10 x 1.51.01.51.022.2±2 520
10 x 2.51.01.51.023.8±2 651
12 x 1.51.01.51.022.9±2 557
12 x 2.51.01.61.024.7±2 714
14 x 1.51.01.61.023.9±2 662
14 x 2.51.01.61.025.9 9±2851
16 x 1.51.01.61.025.3±2 725
16 x 2.51.01.71.027.4 4±2940
19 x 1.51.01.61.026.6±2 830
19 x 2.51.01.71.028.8±2 1050
20 x 1.51.01.71.028.1±2 924
20 x 2.51.01.81.030.4 + 21197
23 x 1.51.01.81.030.4±2 1082
23 x 2.51.01.91.032.9 9±21391
24 x 1.51.01.81.031.2±2 1087
24 x 2.51.01.91.033.8 8±21407
27 x 1.51.01.81.031.9±2 1134
27 x 2.51.01.91.034.5±2 1465
30 x 1.51.01.91.033.1±2 1313
30 x 2.51.02.01.035.9±2 1701
33 x 1.51.01.91.034.3±2 1402
33 x 2.51.02.01.02±2 1822
37 x 1.51.02.01.035.8±2 1517
37 x 2.51.02.11.0.8±21958
44 x 1.51.02.21.040.4±2 1853
44 x 2.51.02.31.043.8±2 2410
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.