HydroCore® Marine Cable NEK 606 Water Blocked P34 BFOU-HCF; 0.6/1KV; Power and Control; Armored; Max. 300,00mm²; 1 to 27 conductors; MICA + XLPE – EPR / SHF2 / HC FIRE / SHF1 / PUR; Fire Resistant; +90°C

HydroCore® Marine Power and Control Cable – Fire Resistant PUR Water Blocked P34 BFOU-HCF 0.6/1 kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Offshore Cable NEK606: Vital Protection Against Fire and WaterDeveloped for the most critical naval and offshore applications. This cable maintains power and control of operational emergency systems during a fire, with maximum protection against water.
  • Extreme Fire Resistance: Ensures the operation of vital circuits during hydrocarbon fires at 1100°C.
  • Double Water Lock: It prevents moisture infiltration with longitudinal and transverse barriers, avoiding failures.
  • Superior Human Security: Halogen-free and with low smoke emissions, essential for crew safety.
  • Robust Construction: Featuring copper armor and double coating for maximum durability in harsh marine environments.
  • Certified Reliability: Meets stringent NEK 606 and IEC standards, ensuring superior performance in critical applications.
PRODUCT DESIGN
  • Conductors: Tinned, annealed, stranded and compacted copper, class 5, according to IEC 60228. Class 2 available upon request.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in Mica tape + EPR upon request.
  • Filling: Water-blocking fillers, if necessary.
  • Bedding: Halogen-free compound, PETP wrapping tape will be applied to the bedding if necessary.
  • Armor: Tinned copper wire braid, PETP wrapping tape will be applied over the braid if necessary.
  • Water Blocking Elements: Water blocking tape and wires to provide longitudinal watertightness.
  • Inner Sheath: Halogen-free thermoset compound, SHF2.
  • Fire protection HC: Extruded thermoplastic compound for fire protection.
  • Tape: Overlapping fiberglass tape.
  • Outer Layer 1: Flame-retardant, halogen-free thermoplastic compound, SHF1.
  • Outer Cover 2: Polyurethane to provide transverse watertightness. In black.
  • Roadway Identification according to NEK TS 606 Standard:
  • One way: Light Gray.
  • Two options: Light Gray, Black.
  • Three colors: Light Gray, Black, Red.
  • Four colors: Light Gray, Black, Red, Blue.
  • Multiple lanes: All lanes are white or light gray, numbered sequentially.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Light Gray, Black.
  • Three-way + ground (4G): Green/Yellow, Light Gray, Black, Red.
  • Four-way + ground (5G): Green/Yellow, Light Gray, Black, Red, Blue.
DETAILS

Benefits

  • Enhanced Fire Safety: Fire-resistant, flame-retardant, and with low emission of smoke and toxic gases.
  • Operation in Extreme Conditions: Maintains circuit integrity and functionality during hydrocarbon fires at 1100°C.
  • Superior Water Protection: Construction with longitudinal and transverse water blocking for maximum protection in humid environments.
  • High Mechanical Durability: Armor with a copper wire mesh and multiple layers that offer robustness and resistance.
  • Halogen-free: Composed of materials that do not emit corrosive gases in case of fire, protecting people and equipment.
  • Reliability in Emergency Situations: Developed for emergency systems that need to operate continuously during a fire.
  • Wide Temperature Range: Reliable performance in an operating temperature range of -20°C to +90°C.
  • Resistance to Harsh Environments: Ideal for use in offshore and marine environments, withstanding harsh conditions.
  • Compliance with Strict Standards: Manufactured in accordance with international standards NEK 606 and various IEC standards.
  • Low Fire Spread: It reduces the risk of fire spreading, increasing the overall safety of the facility.

Applications

  • Offshore Platforms: Power supply, control and lighting systems on oil and gas platforms.
  • Emergency Systems: Used in control and power circuits that must remain operational during a fire.
  • Naval and Maritime Industry: Electrical installations on ships, support vessels and other maritime structures.
  • Floating Production Storage and Offloading (FPSO) Units: Safe electrical connections for production, storage, and transfer systems.
  • Petrochemical Industry: Applications in refineries and processing plants with a high risk of hydrocarbon fires.
  • Lighting and Energy Systems: Power distribution and lighting in areas requiring maximum safety and reliability.
  • Drilling Equipment: Power supply for heavy machinery and control systems in offshore environments.
  • Port Terminals: Feeding cranes and other handling equipment in port areas.
  • Control and Security Modules: Alarm circuits, fire detection, and critical security systems.
  • Offshore Power Generation Projects: Infrastructure for offshore wind and other renewable energy platforms.
TECHNICAL DATA
General information
BrandInnovcable HydroCore®
Product typeOffshore and marine cables NEK606 with water blocking, P34 BFOU-HCF 0.6/1 kV.
ApplicationsUsed for emergency control, power, and lighting systems that need to be operational during a hydrocarbon fire at 1100°C.
Electrical Parameters
Operating Voltage0.6 / 1 kV
Maximum DC resistance at 20°CRanges from 12.2 Ω/km (1.5mm²) to 0.0607 Ω/km (300mm²)
DC Current Capacity @45°C (1 Conductor)Ranges from 23 A (1.5mm²) to 601 A (300mm²)
DC Current Capacity @45°C (2 Conductors)Ranges from 20 A (1.5mm²) to 511 A (300mm²)
DC Current Capacity @45°C (3 & 4 Conductors)Ranges from 16 A (1.5mm²) to 421 A (300mm²)
Short-Circuit Current (1s)Ranges from 210 A (1.5mm²) to 42930 A (300mm²)
Product Design
Conductor MaterialTin-plated, annealed, stranded and compacted copper, class 2, according to IEC 60228.
InsulationMica + XLPE tape without halogen (Lower losses, higher dielectric strength, greater robustness and durability). Available in Mica + EPR tape upon request.
FillingFill with water-blocking seals, if necessary.
SeparatorHalogen-free compound, PETP tape applied over the separator, if necessary.
ArmorTinned copper wire mesh, PETP tape applied over the mesh if necessary.
Water Blocking ElementsWater-blocking tape and wires for longitudinal sealing.
Internal CoatingHalogen-free thermosetting compound, SHF2.
Fire Protection (HC)Extruded thermoplastic compound for fire protection.
TapeOverlapping fiberglass tape.
Exterior Cladding 1Flame-retardant, halogen-free thermoplastic compound, SHF1, in black.
Exterior Cladding 2Polyurethane for transverse sealing.
Identification of the Core Groups
  • Roadway Identification according to NEK TS 606 Standard:
  • One way: Light Gray.
  • Two options: Light Gray, Black.
  • Three colors: Light Gray, Black, Red.
  • Four colors: Light Gray, Black, Red, Blue.
  • Multiple lanes: All lanes are white or light gray, numbered sequentially.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Light Gray, Black.
  • Three-way + ground (4G): Green/Yellow, Light Gray, Black, Red.
  • Four-way + ground (5G): Green/Yellow, Light Gray, Black, Red, Blue.
Product characteristics
Fire resistantYes, fire resistant.
Flame RetardantYes, flame retardant.
Low Smoke EmissionYes, low smoke emission.
Halogen-freeYes, halogen-free.
Radius of Curvature20 x External Diameter (during installation); 12 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Applicable Standards
NEK 606IEC 60092-353
IEC 60331-21IEC 60332-1
IEC 60332 3 22IEC 60754-1,2
IEC 61034-1,2VG 95218 part 29
IEC 60092-360IEC 60228
DIMENSIONAL TABLE
Number of Conductors x Cross-Section (mm²)Nominal Insulation Thickness (mm)Nominal Diameter over the Bed (mm)Nominal Diameter over Cover 1 (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)Nominal Conductor Diameter (mm)Maximum DC Resistance @20°C (Ω/km)Direct Current @45°C 1 Conductor (A)Direct Current @45°C 2 Conductors (A)Direct Current @45°C 3 and 4 Conductors (A)Short-Circuit Current 1s (A)Operating Voltage (kV)
1 x 501.415.018.547.9±2 30458.739119616713771500.6/1
1 x 701.416.520.549.9±2 346510.30.27242206169100200.6/1
1 x 951.618.523.053.3±2 399012.2195293249205135900.6/1
1 x 1201.620.525.055.3±2 447313.8154339288237171700.6/1
1 x 1501.823.027.057.3±2 498815.1126389331272214600.6/1
1 x 1852.025.029.560.3±2 564917.00.1444444311264700.6/1
1 x 2402.228.032.569.2±2 740319.6762522444365343400.6/1
1 x 3002.430.535.571.2±2 840021.9607601511421429300.6/1
2 x 1.51.010.013.042.5±2 19851.612.22320162100.6/1
2 x 2.51.011.014.544.0±2 21842.17.563026213600.6/1
3 x 1.51.010.514.044.0±2 22471.612.22320162100.6/1
3 x 2.51.011.515.044.5±2 23102.17.563026213600.6/1
3 x 41.013.016.545.0±2 25202.64.74034285700.6/1
3 x 61.014.018.047.0±2 27303.23.115244368600.6/1
3 x 161.018.523.052.4±2 36755.11.1696826722900.6/1
3 x 351.225.029.559.9±2 50827.452915713311050100.6/1
3 x 701.433.039.074.4±2 855810.30.27242206169100200.6/1
4 x 2.51.012.516.546.8±2 24152.17.563026213600.6/1
4 x 61.015.519.550.3±2 30143.23.115244368600.6/1
4 x 161.020.525.055.5±2 40225.11.1696826722900.6/1
7 x 1.51.014.017.546.5±2 26781.612.22320162100.6/1
12 x 1.51.018.522.552.0±2 32971.612.22320162100.6/1
27 x 1.51.026.531.066.5±2 53241.612.22320162100.6/1
7 x 2.51.015.019.048.0±2 28982.17.563026213600.6/1
12 x 2.51.020.524.554.0±2 36752.17.563026213600.6/1
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.