HydroCore® Marine Cable NEK 606 Water Blocked P5 or P5/P12 BFOU; 0.6/1KV; Power and Control; Armored; Max. 300,00mm²; 1 to 44 conductors; MICA + XLPE – EPR / SHF2 – SHF MUD / PUR; Fire Resistant; +90°C

HydroCore® Marine Power and Control Cable – Fire Resistant PUR Water Blocked P5 or P5/P12 BFOU 0.6/1KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

The Ultimate Solution in Offshore Cables for Maximum Safety.Designed for the most extreme conditions in marine and offshore environments, this cable ensures the integrity of critical power, control, and lighting systems, offering complete reliability and an impenetrable barrier against failures.
  • Maximum Fire Safety: Fire resistant, with low smoke emission and completely halogen-free.
  • Total Protection Against Moisture: Transverse and longitudinal water blocking that prevents system failures.
  • Robust and Durable Construction: Copper armor and outer coating resistant to mud and abrasion.
  • Ideal for Critical Applications: Ensures performance in offshore power, control, and lighting systems.
  • International Compliance: Certified to the strictest standards, such as NEK 606, guaranteeing its superior quality.
PRODUCT DESIGN
  • Conductors: Class 5 stranded and compacted tinned copper.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in Mica tape + EPR upon request.
  • Filling: Water-blocking fillers, if necessary.
  • Internal coating: Halogen-free compound, PETP packing tape will be applied over the coating, if necessary.
  • Armor: Tinned copper wire mesh, PETP wrapping tape will be applied over the mesh if necessary.
  • Water Blocking Elements: Water blocking tape and cords to provide longitudinal watertightness.
  • Inner Coating: Halogen-free thermosetting compound, SHF2 (for TYPE P5). Halogen-free, mud-resistant thermosetting compound, SHF MUD (for TYPE P5/P12).
  • Outer Cover: Polyurethane to provide transverse water tightness; PE is optional but does not meet the low smoke emission standard. In black.
  • Roadway Identification according to NEK TS 606 Standard:
  • One way: Light Gray.
  • Two options: Light Gray, Black.
  • Three colors: Light Gray, Black, Red.
  • Four colors: Light Gray, Black, Red, Blue.
  • Multiple lanes: All lanes are white or light gray, numbered sequentially.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Light Gray, Black.
  • Three-way + ground (4G): Green/Yellow, Light Gray, Black, Red.
  • Four-way + ground (5G): Green/Yellow, Light Gray, Black, Red, Blue.
DETAILS

Benefits

  • Enhanced Security: Fire-resistant and flame-retardant, ensuring the integrity of the circuits.
  • Environmental Protection: Halogen-free compound with low emission of smoke and toxic gases.
  • Maximum Durability: External polyurethane coating and mud resistance for harsh environments.
  • Reliable Operation: Elements that block water from entering, ensuring cable performance.
  • Superior Insulation: Mica + HEPR/XLPE insulation for high electrical and thermal performance.
  • Mechanical Resistance: Armor with braided tinned copper wire to protect against impacts.
  • Wide Temperature Range: Safe operation in temperatures ranging from -20°C to +90°C.
  • High Conductivity: Tinned copper conductors that prevent oxidation and improve the connection.
  • Versatile Installation: Designed for fixed installations in control, power, and lighting systems.
  • Compliance with Standards: Meets stringent international standards IEC and NEK 606 for offshore use.

Applications

  • Oil Platforms: Power supply for control and energy systems in offshore units.
  • Drilling Probes: Lighting and power circuits in areas with drilling mud.
  • Ships and Vessels: General electrical installations on commercial and service vessels.
  • FPSO Units: Power distribution for production, storage, and transfer equipment.
  • Lighting Systems: Power supply for emergency and service lighting circuits on board.
  • Maritime Automation: Connection of control and instrumentation panels in marine environments.
  • Power Circuits: Power distribution for motors, pumps, and other essential equipment.
  • Shipyards and Ports: Applications in cranes and other load handling equipment.
  • Naval Industry: Used in the construction and repair of different types of ships and floating structures.
  • Critical Security Areas: Ideal for installations where fire safety is paramount.
TECHNICAL DATA

 

General information
Manufacturer/SupplierInnovcable HydroCore®
Product typeOffshore and Marine Watertight Cables, type P5 or P5/P12 BFOU.
Electrical Parameters
Operating Voltage0.6 / 1 kV
Maximum DC Resistance (@ 20°C)Varies with cross-section. Ex: 12,2 Ω/km for 1.5 mm²; 0,0607 Ω/km for 300 mm².
DC Capacity (@ 45°C)Varies with the section and number of lanes. Values ​​specified for 1, 2, 3 and 4 lanes.
Temperature Correction FactorRating factors provided for ambient temperatures from 35°C to 80°C.
Short-Circuit Current (1s)Varies with the cross-section. Ex: 210 A for 1.5 mm²; 42930 A for 300 mm².
Product Design
Conductor MaterialTin-plated, annealed, braided, and compacted copper.
Driver DesignClass 5, according to IEC 60228. Class 2 available upon request.
Roadway Isolation MaterialMica + XLPE tape without halogen (Lower losses, higher dielectric strength, greater robustness and durability). Available in Mica + EPR tape upon request.
Interior BeddingHalogen-free compound.
Shielding / ArmorMesh of tinned copper wires.
Water Blocking ElementsTapes and locking wires for longitudinal sealing.
Inner Cover MaterialHalogen-free thermosetting compound, SHF2 (Type P5).
Outer Cover MaterialPolyurethane for transverse sealing.
Abbreviation for Roofing MaterialInner cover: SHF2 or SHF MUD. Outer cover: Polyurethane (PUR).
Cover ColorBlack inner cover.
Road Identification
  • Roadway Identification according to NEK TS 606 Standard:
  • One way: Light Gray.
  • Two options: Light Gray, Black.
  • Three colors: Light Gray, Black, Red.
  • Four colors: Light Gray, Black, Red, Blue.
  • Multiple lanes: All lanes are white or light gray, numbered sequentially.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Light Gray, Black.
  • Three-way + ground (4G): Green/Yellow, Light Gray, Black, Red.
  • Four-way + ground (5G): Green/Yellow, Light Gray, Black, Red, Blue.
Product characteristics
Application AreaControl, power and lighting systems in offshore and marine installations.
Mud Resistant (MUD)Yes, for type P5/P12 (SHF MUD inner cover).
Minimum Radius of CurvatureFixed installation: 6 x External Diameter; During installation: 8 x External Diameter.
Temperature, fixed installation-20 °C to +90 °C.
Temperature, constant movementNot specified for constant motion (fixed use).
Fire resistanceYes, it is fire-resistant and maintains circuit integrity.
Flame retardantYes, flame retardant and self-extinguishing.
Halogen-freeYes.
Low Smoke EmissionYes.
Oil ResistantMud resistance (MUD) implies resistance to drilling fluids.
Applicable Standards
Main StandardNEK 606
Cable ConstructionIEC 60092-353, IEC 60092-360
ConductorIEC 60228 Class 2
Circuit Integrity (Fire)IEC 60331-21
Flame RetardantIEC 60332-1, IEC 60332-3-22
Halogen and SmokeIEC 60754-1,2, IEC 61034-1,2
watertightnessVG 95218 part 29

 

DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area mm²)Nominal Insulation Thickness (mm)Nominal Bed Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1 x 1.51.01.11.11.011.3±2 152
1 x 2.51.01.11.11.011.7±2 168
1 x 41.01.11.11.012.4 + 2231
1 x 61.01.11.11.012.9 + 2263
1 x 101.01.11.21.014.7±2 326
1 x 161.01.11.21.015.9±2 410
1 x 251.21.11.31.218.7±2 614
1 x 351.21.11.31.219.6±2 725
1 x 501.41.11.41.221.4±2 935
1 x 701.41.11.41.223.0±2 1166
1 x 951.61.11.51.425.9±2 1512
1 x 1201.61.21.61.427.8±2 1822
1 x 1501.81.21.71.429.8±2 2163
1 x 1852.01.21.71.432.2 + 22672
1 x 2402.21.21.81.635.8±2 3329
1 x 3002.41.21.91.638.5±2 4106
2 x 1.51.01.11.21.016.2±2 326
2 x 2.51.01.11.31.017.1±2 378
2 x 41.01.11.31.018.6±2 494
2 x 61.01.11.41.019.9±2 583
2 x 101.01.11.41.021.9±2 740
2 x 161.01.11.51.024.5 + 21034
2 x 251.21.21.61.228.8±2 1428
2 x 351.21.21.71.230.8±2 1701
2 x 501.41.21.91.234.8±2 2405
2 x 701.41.22.11.240.4±2 3423
2 x 951.61.22.31.444.4±2 4106
3 x 1.51.01.11.31.016.8±2 362
3 x 2.51.01.11.31.018.2 + 2467
3 x 41.01.11.31.019.4±2 557
3 x 61.01.11.41.020.7±2 667
3 x 101.01.11.51.023.1±2 872
3 x 161.01.11.51.025.7±2 1218
3 x 251.21.21.71.230.5±2 1722
3 x 351.21.21.81.232.6±2 2079
3 x 501.41.22.01.236.7±2 2888
3 x 701.41.22.21.241.4±2 3859
3 x 951.61.42.41.447.5±2 5203
4 x 1.51.01.11.31.018.4±2 420
4 x 2.51.01.11.31.019.3±2 530
4 x 41.01.11.41.020.8±2 651
4 x 61.01.11.41.022.1±2 788
4 x 101.01.11.51.024.7±2 1034
4 x 161.01.21.61.027.9±2 1470
4 x 251.21.21.81.233.1±2 2095
4 x 351.21.21.91.235.5±2 2562
4 x 501.41.42.01.240.6±2 3602
4 x 701.41.42.21.245.1±2 4830
4 x 951.61.62.41.452.2±2 6442
5 x 1.51.01.11.41.019.7±2 536
5 x 2.51.01.11.41.020.8±2 625
6 x 1.51.01.11.41.021.0±2 572
6 x 2.51.01.11.41.022.4±2 683
7 x 1.51.01.11.41.021.0±2 620
7 x 2.51.01.11.41.022.4±2 735
8 x 1.51.01.11.51.023.8±2 751
8 x 2.51.01.11.51.025.5±2 830
9 x 1.51.01.11.61.025.3±2 756
9 x 2.51.01.11.61.027.1±2 903
10 x 1.51.01.11.61.025.6±2 830
10 x 2.51.01.11.61.027.4±2 1003
12 x 1.51.01.21.61.026.3±2 924
12 x 2.51.01.21.61.028.1±2 1097
14 x 1.51.01.21.71.027.5±2 1013
14 x 2.51.01.21.71.029.3±2 1218
16 x 1.51.01.21.71.028.7±2 1087
16 x 2.51.01.21.81.030.8±2 1328
19 x 1.51.01.21.71.029.4±2 1244
19 x 2.51.01.21.81.031.6±2 1517
20 x 1.51.01.21.81.031.5±2 1323
20 x 2.51.01.21.91.033.8±2 1622
23 x 1.51.01.21.91.033.8±2 1507
23 x 2.51.01.42.01.036.7±2 1895
24 x 1.51.01.22.01.035.2±2 1586
24 x 2.51.01.42.01.037.8±2 1943
27 x 1.51.01.22.01.035.9±2 1696
27 x 2.51.01.42.01.037.4±2 2069
30 x 1.51.01.22.01.036.9±2 1822
30 x 2.51.01.42.11.040.1±2 2347
32 x 1.51.01.42.01.037.5±2 1890
33 x 1.51.01.42.01.038.7±2 2037
33 x 2.51.01.42.21.041.6±2 2510
37 x 1.51.01.42.01.040.0±2 2195
37 x 2.51.01.42.31.043.2±2 2741
44 x 1.51.01.42.31.044.6±2 2583
44 x 2.51.01.42.41.048.2±2 3229
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.