HydroCore® Marine Cable NEK 606 Water Blocked P1 or P1/P8 RFOU/TFOU; 0.6/1KV; Power and Control; Armored; Max. 300,00mm²; 1 to 44 conductors; XLPE – EPR / SHF2 – SHF MUD / PUR; Flame Retardant; +90°C

HydroCore® Marine Power and Control Cable – Flame Retardant PUR Water Blocked P1 or P1/P8 RFOU/TFOU 0.6/1KV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK 606 Offshore Cables: Safety and Performance for Extreme EnvironmentsDesigned for the harshest offshore conditions, this cable offers maximum protection and reliability. Its advanced water-blocking construction ensures continuity of operations, protecting power, control, and lighting systems.
  • Total Protection Against Water: Multiple barriers and an external polyurethane coating for complete watertightness and protection.
  • Maximum Fire Safety: Flame retardant, halogen-free, and low smoke emission to protect lives and equipment.
  • Robust Construction: Mud-resistant (MUD) and with braided armor to withstand the harshest environments.
  • Critical Applications: Ideal for power and control systems on ships, platforms and offshore units.
  • Certified Reliability: Performance guaranteed by stringent industry standards such as NEK 606 and IEC.
PRODUCT DESIGN
  • Conductors: Tin-plated annealed stranded copper to IEC 60228 class 5, Class 2 available upon request.
  • Insulation: Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in EPR upon request.
  • Filling: Water-blocking fillers, if necessary.
  • Interior Bedding: Halogen-free compound.
  • Armor: Mesh of tinned copper wire.
  • Water Blocking Elements: Water blocking tape and cords to provide longitudinal watertightness.
  • Inner Layer: Halogen-free thermosetting compound, SHF2. Halogen-free, mud-resistant thermosetting compound, SHF MUD.
  • Outer layer: Polyurethane to provide transverse watertightness.
DETAILS

Benefits

  • Water and Mud Resistance: Construction with watertight seal and external coating resistant to drilling mud.
  • High Security: Halogen-free material with low smoke emission and flame retardant.
  • Superior Mechanical Protection: Tinned copper wire braid armor protects against impacts.
  • Wide Temperature Range: It operates safely in temperatures ranging from -20°C to +90°C.
  • Robust Construction: Tin-plated copper conductors for increased corrosion resistance in marine environments.
  • Complete Watertightness: Special tapes and fillers ensure longitudinal watertightness against moisture ingress.
  • Low Corrosivity: In case of fire, the emitted gases are of low corrosiveness, protecting electronic equipment.
  • Installation Flexibility: Optimized bending radius for easier mounting in locations with limited space.
  • Compliance with Standards: Designed and certified in accordance with the stringent offshore standards NEK 606 and IEC.
  • Increased Durability: External coating in polyurethane that offers excellent transversal protection.

Applications

  • Oil and Gas Platforms: Ideal for fixed installations on offshore drilling and production units.
  • Power and Lighting Systems: Used for power distribution and lighting circuits on ships.
  • Control Circuits: Application in control and instrumentation systems that require high reliability.
  • Ships and Maritime Units: Suitable for all types of vessels and floating production, storage and offloading (FPSO) units.
  • Areas with Fire Risk: Essential for facilities where human safety and low smoke emissions are critical.
  • Aggressive Environments: Perfect for areas exposed to mud, oil, and other chemicals on deck.
  • Automation Systems: Connecting equipment in automated systems in naval and offshore environments.
  • Low Voltage Panels: Power supply for switchboards and power distribution panels with a voltage of 0.6/1kV.
  • Drilling Equipment: Power linkage and control for heavy machinery used in well drilling.
  • Accommodation Modules: Electrical installations in common areas and control areas on platforms and ships.
TECHNICAL DATA
General information
BrandInnovcable HydroCore®
Product typeOffshore & Marine Cables NEK606 with Water Blocking (RFOU/TFOU).
ApplicationsUsed for control, power, and lighting systems. They are partially water-blocked, flame-retardant, low-smoke, halogen-free, and mud-resistant.
Electrical Parameters
Operating Voltage0.6/1KV
Maximum DC Resistance @20°CIt varies according to the cross-section (e.g., 12.2 Ω/km for 1.5 mm², 0.0607 Ω/km for 300 mm²).
DC Capacity @45°CIt varies with the number of conductors and the cross-sectional area (see the electrical characteristics table for specific values).
Short-Circuit Current (1s)It varies according to the cross-section (e.g., 210 A for 1.5 mm², 42930 A for 300 mm²).
Product Design
Conductor MaterialAnnealed tin-plated copper, stranded, class 2 according to IEC 60228.
InsulationHalogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). Available in EPR upon request.
FillerWater-locking fillers, if needed.
Separator (Bedding)Halogen-free compound. PETP tape can be applied over the separator.
Shielding / ArmorTin-plated copper wire mesh. PETP tape can be applied over the mesh.
Water Blocking ElementsTape and wires that block water to ensure longitudinal watertightness.
Inner LayerHalogen-free thermosetting compound, SHF2 (for TYPE P1). Halogen-free and mud-resistant thermosetting compound, SHF MUD (for TYPE P1/P8), black color.
Outer CoverPolyurethane for cross-tight sealing. PE is optional, but does not meet the low smoke emission standard.
Cable FormatRound
Product characteristics
Mud resistantYes.
Low Smoke EmissionYes.
Halogen-freeYes.
Mechanical and Thermal Properties
Minimum Radius of Curvature8 x External Diameter (during installation); 6 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Applicable Standards
IEC 60092-353Design and construction.
IEC 60092-360Insulation and cladding materials.
IEC 60332-1Flame retardancy (single cable test).
IEC 60332 3 22Fire propagation retardancy (cable bundle test, Category A).
IEC 60754-1,2Emission of corrosive and acidic gases (halogen-free).
IEC 61034-1,2Low smoke emission.
NEK 606General specification for offshore cables.
VG 95218 part 29Water tightness.
DIMENSIONAL TABLE

 

Construction (Number of conductors x Cross-sectional area in mm²)Nominal Insulation Thickness (mm)Nominal Bed Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1 x 1.51.01.11.11.010.9±2 142
1 x 2.51.01.11.11.011.3±2 158
1 x 41.01.11.11.011.9±2 189
1 x 61.01.11.11.012.4 + 2215
1 x 101.01.11.21.014.2±2 310
1 x 161.01.11.21.015.5±2 404
1 x 251.21.11.21.217.8±2 551
1 x 351.21.11.31.219.3±2 719
1 x 501.41.11.41.221.1±2 914
1 x 701.41.11.41.222.8±2 1160
1 x 951.61.11.51.425.6±2 1507
1 x 1201.61.21.61.427.7±2 1832
1 x 1501.81.21.61.429.6±2 2158
1 x 1852.01.21.71.432.1±2 2688
1 x 2402.21.21.81.635.7±2 3350
1 x 3002.41.21.91.638.4±2 4132
1 x 4002.41.42.11.643.7±2 5313
1 x 5002.41.42.21.647.2±2 6489
1 x 6302.41.42.31.651.2±2 8001
2 x 1.51.01.11.21.015.6±2 310
2 x 2.51.01.11.21.016.4±2 352
2 x 41.01.11.31.018.1±2 467
2 x 61.01.11.31.019.1±2 546
2 x 101.01.11.41.021.3±2 714
2 x 161.01.11.51.023.7±2 1003
2 x 251.21.21.61.228.3±2 1402
2 x 351.21.21.71.230.3±2 1675
2 x 501.41.21.91.234.3±2 2363
2 x 701.41.22.11.238.2±2 2935
2 x 951.61.22.31.444.0±2 3969
2 x 1201.61.42.41.447.6±2 4788
2 x 1501.81.42.61.452.0±2 5775
2 x 1852.01.42.71.456.6±2 7009
2 x 2402.21.63.01.664.2 + 29035
2 x 3002.41.63.21.670.2±2 11036
3 x 1.51.01.11.21.016.2±2 336
3 x 2.51.01.11.31.017.6±2 436
3 x 41.01.11.31.018.8±2 525
3 x 61.01.11.41.020.1±2 635
3 x 101.01.11.41.022.3±2 835
3 x 161.01.11.51.024.8±2 1181
3 x 251.21.21.61.229.9±2 1701
3 x 351.21.21.71.232.0±2 2053
3 x 501.41.21.91.236.3±2 2867
3 x 701.41.42.01.240.8±2 3838
3 x 951.61.42.21.446.6±2 5129
3 x 1201.61.42.31.450.4±2 6300
3 x 1501.81.62.51.455.2±2 7665
3 x 1852.01.62.71.461.4±2 9408
3 x 2402.21.82.91.669.3±2 12191
3 x 3002.21.83.41.674.1±2 14165
4 x 1.51.01.11.31.017.7±2 368
4 x 2.51.01.11.31.018.6±2 446
4 x 41.01.11.41.020.1±2 620
4 x 61.01.11.41.021.5±2 761
4 x 101.01.11.51.024.1±2 1003
4 x 161.01.21.61.027.2±2 1444
4 x 251.21.21.71.232.4±2 2063
4 x 351.21.21.81.234.8±2 2531
4 x 501.41.42.01.239.7±2 3533
4 x 701.41.42.21.244.5±2 4809
4 x 951.61.42.41.451.0±2 6321
4 x 1201.61.62.51.455.5±2 7812
4 x 1501.81.62.91.461.1±2 9240
4 x 1852.01.63.11.466.8±2 11298
4 x 2402.21.83.41.675.6±2 14585
4 x 3002.41.83.71.683.0±2 18275
5 x 1.51.01.11.31.018.7±2 441
5 x 2.51.01.11.41.020.0±2 583
6 x 1.51.01.11.31.019.8±2 520
6 x 2.51.01.11.41.021.2±2 620
7 x 1.51.01.11.31.019.8±2 567
7 x 2.51.01.11.41.021.2 + 2688
8 x 1.51.01.11.51.022.3±2 677
8 x 2.51.01.11.51.023.8±2 814
9 x 1.51.01.11.51.023.5±2 709
9 x 2.51.01.11.61.025.3±2 824
10 x 1.51.01.11.51.023.8±2 740
10 x 2.51.01.11.61.025.6±2 908
12 x 1.51.01.11.51.024.5±2 845
12 x 2.51.01.11.61.026.5±2 1003
14 x 1.51.01.11.61.025.6±2 903
14 x 2.51.01.11.71.027.5±2 1124
16 x 1.51.01.11.71.026.9±2 987
16 x 2.51.01.11.71.028.7±2 1213
19 x 1.51.01.11.71.028.0±2 1155
19 x 2.51.01.11.81.030.2 + 21428
20 x 1.51.01.11.71.029.2 + 21187
20 x 2.51.01.11.81.031.5±2 1481
23 x 1.51.01.11.81.031.3±2 1349
23 x 2.51.01.11.91.033.8±2 1691
24 x 1.51.01.11.81.032.0±2 1370
24 x 2.51.01.22.01.035.2±2 1775
27 x 1.51.01.11.91.032.8±2 1533
27 x 2.51.01.22.01.035.9±2 1906
30 x 1.51.01.11.91.033.8±2 1596
30 x 2.51.01.22.01.036.9±2 2058
33 x 1.51.01.22.01.035.5±2 1754
33 x 2.51.01.22.11.038.7±2 2300
37 x 1.51.01.22.01.036.6±2 1932
37 x 2.51.01.22.11.040.0±2 2489
44 x 1.51.01.22.21.041.2±2 2321
44 x 2.51.01.22.31.044.6±2 2935
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.