HydroCore® Marine Cable NEK 606 Water Blocked P18 RU; 0.6/1KV; Power and Control; Max. 300,00mm²; 1 to 44 conductors; EPR / SHF2 / PUR; Flame Retardant; +90°C

HydroCore® Marine Power and Control Cable – Flame Retardant PUR Water Blocked P18 RU 0.6/1kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Superior Protection and Reliability for Offshore and Marine SystemsDesigned for the most demanding offshore and naval applications, where failure is not an option. Its robust construction with double water lock ensures the integrity of power and data in critical systems.
  • Total Water Blockage: Longitudinal and transverse protection against moisture, ensuring operational continuity.
  • Maximum Fire Safety: Halogen-free, with low smoke emission and flame-retardant properties.
  • Extremely Robust: Polyurethane coating resistant to abrasion, oils and harsh environments.
  • Versatile Application: Perfect for control, power, and lighting systems on platforms and vessels.
  • Certified Quality: Compliant with stringent NEK 606 and IEC standards for maximum performance.
PRODUCT DESIGN
  • Conductors: Tin-plated annealed stranded copper to IEC 60228 class 5. Class 2 available upon request.
  • Insulation: Halogen-free EPR.
  • Filling: Water-blocking fillers, if necessary.
  • Water-blocking elements: Water-blocking tape and ropes to provide longitudinal watertightness.
  • Inner sheath: Halogen-free thermosetting compound, SHF2, black color.
  • Outer layer: Polyurethane to provide transverse water tightness.
DETAILS

Benefits

  • Maximum Security: Halogen-free material with low smoke emission and flame retardant properties, minimizing risks in case of fire.
  • Moisture Protection: Partially sealed against water, with elements that guarantee longitudinal and transverse watertightness.
  • High Durability: Tinned copper conductors with an outer polyurethane coating, offering resistance in harsh environments.
  • Compliance with Standards: Designed in accordance with the stringent international standards NEK 606 and IEC for offshore and marine use.
  • Structural Integrity: Robust construction with EPR insulation, ensuring reliable and long-lasting electrical performance.
  • Wide Temperature Range: Safe operation in a temperature range of -20°C to +90°C, adapting to various climatic conditions.
  • Installation Flexibility: Optimized bending radius that facilitates assembly in confined spaces on ships and platforms.
  • Low Corrosivity: The halogen-free composition protects sensitive equipment and metal structures from corrosive gases.
  • Complete Seal: Water-blocking tapes and fillers prevent moisture from penetrating along the cable, preserving its lifespan.
  • Superior Electrical Performance: Maximum guaranteed DC resistance for efficient power transmission with reduced losses.

Applications

  • Control Systems: Used for wiring control systems on ships, oil platforms, and other maritime units.
  • Power Distribution: Ideal for power supply circuits for onboard equipment and systems that require high reliability.
  • Lighting Design Projects: Used in general and emergency lighting systems in offshore and naval environments.
  • Naval and Offshore Industry: Designed specifically for fixed installations on ships, drilling rigs, and production platforms.
  • Wet or humid areas: Its water-blocking feature makes it perfect for installations subject to sea air and constant humidity.
  • Critical Security Zones: Used in areas where fire safety is paramount, due to its flame-retardant properties.
  • Navigation Equipment: Connection of control panels and devices in control bridges and control rooms.
  • Maritime Automation: Wiring for sensors and actuators in automated systems on board modern vessels.
  • Maritime Industrial Applications: Suitable for use on port cranes, conveyor belts and other machinery in coastal areas.
  • Communication Systems: It can be used in low-voltage circuits for internal communication and alarm systems.
TECHNICAL DATA
General information
Product typeOffshore & Marine Cables NEK606 with P18 RU water locking.
ApplicationsUsed for control, power, and lighting systems.
Electrical Parameters
Operating Voltage0.6 / 1 kV
Maximum DC Resistance of the Conductor at 20°CIt varies from 12.2 Ω/km (1.5mm²) to 0.0607 Ω/km (300mm²).
DC Capacity at 45°CVaries depending on the cross-section and number of lanes (see the complete data table for specific values).
Short-Circuit Current (1s)It ranges from 210 A (1.5 mm²) to 42930 A (300 mm²).
Product Design
Conductor MaterialTin-plated, annealed, and stranded copper, class 5 according to IEC 60228. Class 2 available upon request.
InsulationHalogen-free EPR.
FillFill with water-blocking seals, if necessary.
Water Blocking ElementsWater-blocking tape and wires for longitudinal sealing.
Inner LayerHalogen-free thermosetting compound, SHF2, in black.
Outer CoverPolyurethane for watertightness across the surface (PE is optional, but does not meet the low smoke emission standard).
Nominal Cross SectionAvailable in sizes from 1.5 mm² to 300 mm².
Number of RoadsAvailable in 1, 2, 3, 4 and more way configurations.
Product characteristics
Water ResistancePartially sealed against water; longitudinal and transverse watertightness.
Fire resistanceFlame retardant.
Smoke EmissionLow smoke emission.
Halogen-freeYes.
Radius of Curvature8 x External Diameter (during installation); 6 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Ambient Temperature Correction FactorsFactors applicable for temperatures from 35°C to 80°C.
Applicable Standards
NEK 606IEC 60092-353
IEC 60092-360IEC 60332-1
IEC 60332 3 22IEC 60754-1,2
IEC 61034-1,2VG 95218 part 29
IEC 60228 class 2IEC 60092-351
IEC 60092-359
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area mm²)Nominal Insulation Thickness (mm)Nominal Thickness of Internal Cover (mm)Nominal Thickness of the External Cover (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)Nominal Conductor Diameter (mm)Maximum DC Resistance @20°C (Ω/km)Direct Current @45°C 1 Conductor (A)Direct Current @45°C 2 Conductors (A)Direct Current @45°C 3 and 4 Conductors (A)Short-Circuit Current 1s (A)Operating Voltage (kV)
1 x 1.51.01.01.08.0±2 631.612.223--2100.6/1
1 x 2.51.01.01.08.5±2 842.17.5630--3600.6/1
1 x 41.01.01.09.1±2 1162.64.740--5700.6/1
1 x 61.01.01.09.6±2 1373.23.1152--8600.6/1
1 x 101.01.11.010.5±2 17341.8472--14300.6/1
1 x 161.01.11.011.8±2 2475.11.1696--22900.6/1
1 x 251.21.21.214.1±2 3736.5734127--35800.6/1
1 x 351.21.21.215.2±2 4787.4529157--50100.6/1
1 x 501.41.31.216.8±2 6258.7391196--71500.6/1
1 x 701.41.41.218.7±2 84510.30.27242--100200.6/1
1 x 951.61.51.421.5±2 114512.2195293--135900.6/1
1 x 1201.61.51.423.1±2 141213.8154339--171700.6/1
1 x 1501.81.61.425.2±2 171715.1126389--214600.6/1
1 x 1852.01.71.427.7±2 217917.00.1444--264700.6/1
1 x 2402.21.81.631.2±2 279319.6762522--343400.6/1
1 x 3002.41.91.634.0±2 350721.9607601--429300.6/1
2 x 1.51.01.11.011.7±2 1521.612.2-20---
2 x 2.51.01.11.012.5±2 1842.17.56-26---
2 x 41.01.21.013.6±2 2362.64.7-34---
2 x 61.01.21.014.9±2 3103.23.11-44---
2 x 101.01.31.016.8±2 44141.84-61---
2 x 161.01.41.019.2±2 6355.11.16-82---
2 x 251.21.51.223.7±2 9876.5734-108---
2 x 351.21.61.225.7±2 12447.4529-133---
2 x 501.41.81.229.3±2 16648.7391-167---
2 x 701.41.91.234.3±2 239410.30.27-206---
2 x 951.62.11.439.7±2 324512.2195-249---
3 x 1.51.01.11.012.3±2 1731.612.2--16--
3 x 2.51.01.21.013.1±2 2152.17.56--21--
3 x 41.01.21.014.5±2 2942.64.7--28--
3 x 61.01.31.015.6±2 3783.23.11--36--
3 x 101.01.31.018.0±2 55741.84--50--
3 x 161.01.41.020.5±2 8095.11.16--67--
3 x 251.21.61.225.3±2 12606.5734--89--
3 x 351.21.71.227.4±2 16017.4529--110--
3 x 501.41.81.231.1±2 21328.7391--137--
3 x 701.42.01.235.0±2 290310.30.27--169--
3 x 951.62.21.440.4±2 393212.2195--205--
4 x 1.51.01.21.013.2±2 2101.612.2--16--
4 x 2.51.01.21.014.4±2 2682.17.56--21--
4 x 41.01.31.015.7±2 3572.64.7--28--
4 x 61.01.31.017.2±2 4783.23.11--36--
4 x 101.01.41.019.5±2 69841.84--50--
4 x 161.01.51.022.4±2 10195.11.16--67--
4 x 251.21.71.227.9±2 16076.5734--89--
4 x 351.21.81.230.2±2 20537.4529--110--
4 x 501.42.01.234.3±2 27308.7391--137--
4 x 701.42.11.238.7±2 371710.30.27--169--
4 x 951.62.41.444.8±2 505612.2195--205--
5 x 1.51.01.21.015.1±2 257-------
5 x 2.51.01.31.016.3±2 320-------
6 x 1.51.01.31.016.4±2 289-------
6 x 2.51.01.31.017.6±2 378-------
7 x 1.51.01.31.016.4±2 299-------
7 x 2.51.01.31.017.6±2 410-------
8 x 1.51.01.41.018.9±2 399-------
8 x 2.51.01.41.020.4±2 520-------
9 x 1.51.01.41.020.1±2 415-------
9 x 2.51.01.51.021.9±2 530-------
10 x 1.51.01.41.020.4±2 457-------
10 x 2.51.01.51.022.2 + 2599-------
12 x 1.51.01.41.021.0±2 509-------
12 x 2.51.01.51.022.9±2 656-------
14 x 1.51.01.51.022.2±2 593-------
14 x 2.51.01.51.023.9±2 772-------
16 x 1.51.01.51.023.3±2 646-------
16 x 2.51.01.61.025.3±2 851-------
19 x 1.51.01.61.024.6±2 751-------
19 x 2.51.01.61.026.6±2 982-------
20 x 1.51.01.61.025.8±2 819-------
20 x 2.51.01.71.028.1±2 1087-------
23 x 1.51.01.71.027.9±2 950-------
23 x 2.51.01.81.030.4±2 1265-------
24 x 1.51.01.71.028.6±2 966-------
24 x 2.51.01.81.031.2±2 1281-------
27 x 1.51.01.71.029.2 + 21034-------
27 x 2.51.01.81.031.9±2 1360-------
30 x 1.51.01.81.030.4±2 1166-------
30 x 2.51.01.91.033.1±2 1549-------
33 x 1.51.01.81.031.5±2 1250-------
33 x 2.51.01.91.034.3±2 1664-------
37 x 1.51.01.91.032.8±2 1381-------
37 x 2.51.02.01.035.8±2 1817-------
44 x 1.51.02.01.036.8±2 1638-------
44 x 2.51.02.21.040.4±2 2205-------
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.