HydroCore® Marine Cable NEK 606 Water Blocked P30 TFOU-HCF; 6/10(12) kV; Medium Voltage Power; Armored; Max. 300,00 mm²; 1 and 3 conductors; XLPE / SHF2 / HC FIRE / SHF1 / PUR; Fire resistant; +90°C
HydroCore® Medium Voltage Marine Cable – Fire Resistant PUR Water Blocked P30 TFOU-HCF 6/10(12) kV
💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.
- Extreme Fire Resistance: Operational in hydrocarbon fires at 1100°C, keeping emergency systems active.
- Total Protection Against Water: Double interlocking system (transverse and longitudinal) that prevents failures due to moisture or corrosion.
- Maximum Human Safety: Low smoke zero halogen (LSZH) is essential for safety during evacuations.
- Robust Construction: Armor and coatings for harsh environments, operating from -20°C to +90°C.
- Certified Quality: Full compliance with the stringent NEK 606 and IEC standards for offshore use.
|
Benefits
| Applications
|
| General information | |
|---|---|
| Product type | Offshore and Marine Watertight Cables NEK606, models P30 TFOU-HCF. HydroCore® |
| Applications | Used for emergency, control, power, and lighting systems that need to operate during a hydrocarbon fire at 1100°C. |
| Electrical Parameters | |
| Operating Voltage | 6/10(12) kV |
| Rated Continuous Current @45°C (1 Conductor) | It varies from 242 A to 601 A, depending on the cross-section. |
| Rated Continuous Current @45°C (3 Conductors) | It varies from 169 A to 421 A, depending on the cross-section. |
| Short-Circuit Current (1s) | It varies from 10020 A to 42930 A, depending on the cross-section. |
| Maximum DC Resistance @20°C | It varies from 0.0607 Ω/km to 0.27 Ω/km, depending on the cross-section. |
| Product Design | |
| Conductor Material | Braided, ringed and tinned copper, class 2, according to IEC 60228. |
| Driver's Screen | Semiconductor material. |
| Insulation | Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability). TFOU |
| Isolation Screen | Semiconductor material and tinned copper wire braid. |
| Fillers | Water-blocking fillers, if necessary. |
| Bed | Halogen-free compound. PETP tape can be applied over the bed. |
| Armor | Braid made of tinned copper wire. PETP tape can be applied over the braid. |
| Water Blocking Elements | Water-blocking tape and threads for longitudinal sealing. |
| Inner Layer | Halogen-free thermosetting compound, SHF2, red in color. |
| Fire Protection (HC) | Extruded thermoplastic compound for fire protection. |
| Protective Tape | Overlapping fiberglass tape. |
| Outer Cover 1 | Flame-retardant, halogen-free thermoplastic compound, SHF1. |
| Outer Cover 2 | Polyurethane for cross-tight sealing. PE is optional, but does not meet the low smoke emission standard. |
| Product characteristics | |
| Fire resistant | Yes, resistant to hydrocarbon fires up to 1100°C. |
| Flame Retardant | Yes. |
| Low Smoke Emission | Yes. |
| Halogen-free | Yes. |
| Partially Blocked Against Water | Yes. |
| Mechanical and Thermal Properties | |
| Minimum Radius of Curvature | 20 x External Diameter (during installation); 12 x External Diameter (after installation). |
| Temperature Range | -20 ° C to + 90 ° C. |
| Dimensions and Weight | |
| Number of Conductors x Cross-Section | Available in 1 or 3 conductor configurations, with cross-sections from 50 to 300 mm². |
| Nominal Outside Diameter | It varies from 64.4 mm to 108.8 mm, depending on the configuration. |
| Nominal Weight | It varies from 5481 kg/km to 18270 kg/km, depending on the configuration. |
| Applicable Standards | |
| NEK 606 | IEC 60092-354 |
| IEC 60092-360 | IEC 60331-21 (Circuit Integrity) |
| IEC 60332-1 (Flame Retardant) | IEC 60332-3-22 (Reduced Fire Spread) |
| IEC 60754-1,2 (Halogen-free, Low Corrosivity) | IEC 61034-1,2 (Low Smoke Emission) |
| VG 95218 part 29 (Water Tightness) | IEC 60228 class 2 |
| Construction | Nominal Insulation Thickness (mm) | Nominal Diameter Over the Inner Cover (mm) | Nominal Diameter Over the Inner Sheath (mm) | Nominal Outside Diameter (mm) | Nominal Weight (kg/km) | Nominal Conductor Diameter (mm) | Maximum DC Resistance at 20°C (Ω/km) | DC Capacity at 45°C 1 Channel (A) | DC Capacity at 45°C 3-Way (A) | Short-Circuit Current 1s (A) | Operating Voltage (kV) |
| 1 x 70 | 3.4 | 23.5 | 30.0 | 5481 | 10.3 | 0.27 | 242 | 10020 | 6/10 | ||
| 1 x 95 | 3.4 | 25.5 | 32.0 | 6195 | 12.2 | 195 | 293 | 13590 | 6/10 | ||
| 1 x 120 | 3.4 | 27.5 | 34.0 | 6657 | 13.8 | 154 | 339 | 17170 | 6/10 | ||
| 1 x 150 | 3.4 | 28.5 | 35.0 | 7004 | 15.1 | 126 | 389 | 21460 | 6/10 | ||
| 1 x 185 | 3.4 | 30.5 | 36.5 | 7686 | 17.0 | 0.1 | 444 | 26470 | 6/10 | ||
| 1 x 240 | 3.4 | 33.0 | 39.0 | 8663 | 19.6 | 762 | 522 | 34340 | 6/10 | ||
| 1 x 300 | 3.4 | 35.0 | 41.5 | 9744 | 21.9 | 607 | 601 | 42930 | 6/10 | ||
| 3 x 50 | 3.4 | 47.0 | 55.0 | 11519 | 169 |
Related products
Shipping and Delivery Times – FAQ
Q: How does product shipping work?
A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.
Q: What is the delivery time for my order?
A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.
Availability Period:
Products in Stock: If the product is in stock, it will be shipped within 2 business days.
Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.
Carrier's deadline:
This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.
Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.
Q: Why the 15 business day production lead time? What if there are delays?
A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.
Q: Can I cancel an order that is already in production?
A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.
Shipping Costs
Q: How is the shipping cost calculated?
A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.
Q: Do you offer free shipping?
A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.
Warranty and Returns
Q: What is the return and exchange policy?
A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.
Q: Do the products have a warranty?
A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.
Loading and Transportation
1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.
* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.
2- In the case of a forklift, the drums must not be damaged by the forklift.
* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.
Transportation and unloading
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
Checks when handling cables – Storage
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.