HydroCore® Marine Cable NEK 606 Water Blocked P6 or P6/P13 BFOU; 3.6/6KV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 3 conductors; MICA + XLPE / SHF2 – SHF MUD / PUR; Fire resistant; +90°C

HydroCore® Medium Voltage Marine Cable – Fire Resistant PUR Water Blocked P6 or P6/P13 BFOU 3.6/6kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK 606 Offshore Cable: Safety and Performance in Extreme EnvironmentsDeveloped for the most demanding medium-voltage offshore installations. This cable offers superior protection against water, fire, and mud, ensuring the integrity and continued safety of your operation.
  • Total Protection Against Water: Double sealing with tapes and fillers for maximum watertightness and performance.
  • High Fire Safety: Fire resistant, with low smoke emission and completely halogen-free.
  • Robust Construction: Polyurethane coating and mud-resistant option for durability in harsh conditions.
  • Reliable Electrical Performance: Braided copper conductors and shielding for stable power transmission.
  • Guaranteed Application: Ideal for fixed installations, it operates from -20°C to +90°C and meets the NEK 606 standard.
PRODUCT DESIGN
  • Conductors: Stranded, tinned and annealed copper, circular, class 5, according to IEC 60228. Class 2 available upon request.
  • Conductor Screen: Semiconductor material.
  • Insulation: Mica tape + halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire braid.
  • Filling: Water-blocking fillers, if necessary.
  • Bed linen: Halogen-free compound.
  • Armor: Braid of tinned copper wire.
  • Water Blocking Elements: Water blocking tape and threads to provide longitudinal watertightness.
  • Inner Layer: Halogen-free, mud-resistant thermosetting compound (SHF MUD), red color.
  • Outer layer: Polyurethane to provide transverse water tightness.
DETAILS

Benefits

  • Maximum Fire Safety: Fire resistant and with low flame spread, ensuring the integrity of circuits in critical situations.
  • Personal and Equipment Protection: Halogen-free and with low smoke emission, it prevents the release of toxic and corrosive gases during a fire.
  • Total Watertightness: Designed with multiple water-blocking elements, it offers superior protection against moisture and longitudinal and transverse immersion.
  • Resistance to Harsh Environments: Robust, mud-resistant casing (MUD), ideal for the harsh conditions found on drilling rigs.
  • High Mechanical Durability: Reinforced construction with copper braid, ensuring protection against impacts and mechanical stress in offshore environments.
  • Medium Voltage Reliability: High-performance insulation for 3.6/6kV power systems, ensuring stable and safe power transmission.
  • Corrosion Resistance: Tinned copper conductors that prevent oxidation and ensure long-lasting electrical connections in saline atmospheres.
  • Operation in Extreme Temperatures: Suitable for operation in a wide temperature range (-20°C to +90°C), adapting to diverse climates.
  • International Compliance: Certified according to the stringent NEK 606 and IEC standards, attesting to its quality and safety for maritime use.
  • Secure and Fixed Installation: Designed specifically for fixed installations, providing a long-term power cabling solution.

Applications

  • Oil and Gas Platforms: Medium voltage power supply systems in fixed offshore installations.
  • Drilling Probes: Cabling for essential equipment in areas exposed to mud and drilling fluids.
  • Ships and Vessels: Power distribution on cargo ships, drill ships, and other maritime vessels.
  • FPSO Units: Used in floating production, storage and transfer units for energy systems.
  • Naval Industry and Shipyards: Applications in the construction and modernization of vessels that require high safety and durability.
  • Port Terminals: Feeding cranes and other heavy equipment in coastal areas with high salinity.
  • Offshore Renewable Energy: Connection of turbines and substations in wind farm or tidal energy projects.
  • Emergency Circuits: Ideal for critical power systems that need to operate even during a fire.
  • Production and Accommodation Modules: Safe wiring for operational and residential areas in offshore structures.
  • Coastal Installations: Applications in any coastal environment that demands superior resistance to moisture and corrosion.
TECHNICAL DATA
General information
BrandInnovcable HydroCore®
Product typeOffshore & Marine Cables NEK606 with Water Lockout (P6 or P6/P13 BFOU).
ApplicationsFixed installation for medium voltage power. Cables partially blocked against water, fire resistant, flame retardant, low smoke emission, halogen free and mud resistant.
Electrical Parameters
Operating Voltage3.6/6kV.
Maximum DC resistance at 20°CIt varies from 0.734 Ω/km (25mm²) to 0.0286 Ω/km (630mm²).
DC Capacity at 45°C (1 Core)It ranges from 127 A (25 mm²) to 890 A (630 mm²).
DC Capacity at 45°C (3 Cores)It ranges from 89 A (25 mm²) to 623 A (630 mm²).
Short-Circuit Current (1s)It ranges from 3580 A (25 mm²) to 90140 A (630 mm²).
Product Design
Conductor MaterialCircular tin-plated braided wire, class 2, according to IEC 60228.
Driver's ScreenSemiconductor material.
InsulationHalogen-free Mica + XLPE tape (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire mesh.
FillWater-locking fillers, if needed.
Separator (Bedding)Halogen-free compound. PETP tape can be applied over the separator.
ArmorTin-plated copper wire mesh. PETP tape can be applied over the mesh.
Water Blocking ElementsWater-blocking tape and wires for longitudinal sealing.
Inner LayerHalogen-free thermoset compound, SHF2 (for TYPE P6), or halogen-free mud-resistant thermoset compound, SHF MUD (for TYPE P6/P13), red color.
External CoverPolyurethane for transverse sealing (PE is optional, but does not meet the low smoke emission standard).
Cable FormatRound.
Product characteristics
Minimum Radius of Curvature15 x External Diameter (during installation); 9 x External Diameter (fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Flame RetardantAccording to IEC 60332-1.
Reduced Fire SpreadAccording to IEC 60332-3-22.
Fire Resistance (Circuit Integrity)According to IEC 60331-21.
Halogen-freeAccording to IEC 60754-1.
Low CorrosivityAccording to IEC 60754-2.
Low Smoke EmissionAccording to IEC 61034-1 & 2.
Water tightnessAs per VG 95218-29.
Mud ResistantYes (for type P6/P13).
Applicable Standards
NEK 606IEC 60092-351
IEC 60092-354IEC 60092-359
IEC 60092-360IEC 60228 Class 2
IEC 60331-21IEC 60332-1
IEC 60332 3 22IEC 60754-1,2
IEC 61034-1,2VG 95218 part 29
DIMENSIONAL TABLE
Construction (Number of cores x Cross-sectional area mm²)Nominal Cross-Sectional Area (mm²)Nominal Conductor Diameter (mm)Nominal Insulation Thickness (mm)Nominal Bed Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)Maximum DC Resistance @20°C (Ω/km)DC Rating @45°C 1 Core (A)DC Rating @45°C 3 Cores (A)Short-Circuit Current 1s (A)Operating Voltage (KV)
1 x 1616N/A2.51.51.21.026.8±2 998N/AN/AN/AN/AN/A
1 x 25256.52.51.61.21.228.7±2 11667341278935803.6/6
1 x 35357.42.51.61.21.230.0±2 132352915711050103.6/6
1 x 50508.72.51.71.31.231.5±2 153339119613771503.6/6
1 x 707010.32.51.71.31.233.3±2 1827270242169100203.6/6
1 x 959512.22.51.81.41.436.0±2 2216195293205135903.6/6
1 x 12012013.82.51.91.41.437.7±2 2552154339237171703.6/6
1 x 15015015.12.51.91.41.439.7±2 3035126389272214603.6/6
1 x 18518517.02.52.01.51.441.9±2 3539100444311264703.6/6
1 x 24024019.62.62.11.61.645.4±2 4305762522365343403.6/6
1 x 30030021.92.82.21.61.647.9±2 5051607601421429303.6/6
3 x 1616N/A2.52.31.71.049.8±2 3728N/AN/AN/AN/AN/A
3 x 2525N/A2.52.51.81.253.9±2 4389734N/A8935803.6/6
3 x 3535N/A2.52.61.91.257.1±2 5061529N/A11050103.6/6
3 x 5050N/A2.52.71.91.259.8±2 5765391N/A13771503.6/6
3 x 7070N/A2.52.82.01.264.0±2 6920270N/A169100203.6/6
3 x 9595N/A2.53.02.11.469.0±2 8316195N/A205135903.6/6
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.