HydroCore® Marine Cable NEK 606 Water Blocked P7 or P7/P14 BFOU; 6/10kV; Medium Voltage Power; Armored; Max. 300,00mm²; 1 to 3 conductors; MICA + XLPE / SHF2 – SHF MUD / PUR; Fire resistant; +90°C

HydroCore® Medium Voltage Marine Cable – Fire Resistant PUR Water Blocked P7 or P7/P14 BFOU 6/10kV

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

NEK606 Offshore Cable: Secure Power for Extreme EnvironmentsDesigned for the harshest offshore conditions, this cable offers maximum reliability. Its robust construction with water blocking and mud resistance ensures continuous and secure power, protecting your assets and operations against outages and harsh environments.
  • Maximum Fire Safety: Fire-resistant, low-smoke, and halogen-free to protect lives and equipment.
  • Total Protection Against Moisture: Water shutoff prevents failures, ensuring circuit integrity and operational continuity.
  • Resistance to Mud and Abrasion: Special coating (SHF MUD) that withstands the most severe drilling and installation conditions.
  • Superior Mechanical Durability: Constructed with copper conductors and reinforced shielding to withstand impacts and twisting.
  • Performance in Extreme Climates: Reliable operation from -20°C to +90°C, ensuring consistent performance in any scenario.
PRODUCT DESIGN
  • Conductors: Tin-plated circular braided copper, class 5 according to IEC 60228. Class 2 available upon request.
  • Conductor Screen: Semiconductor material.
  • Insulation: Halogen-free XLPE (Lower losses, higher dielectric strength, greater robustness and durability).
  • Insulation Screen: Semiconductor material and tinned copper wire braid.
  • Filling: Water-blocking fillers, if necessary.
  • Internal Coating: Halogen-free compound, PETP wrapping tape will be applied over the coating, if necessary.
  • Armor: Tinned copper wire braid, PETP wrapping tape will be applied over the braid if necessary.
  • Water Blocking Elements: Water blocking tape and cords to provide longitudinal watertightness.
  • Inner Cover: Halogen-free thermosetting compound, SHF2 (for TYPE P7), or halogen-free mud-resistant thermosetting compound, SHF MUD (for TYPE P7/P14), in red.
  • Outer Cover: Polyurethane to provide transverse tightness; PE is optional but does not meet the low smoke emission standard.
DETAILS

Benefits

  • Maximum Fire Safety: Fire-resistant construction, flame retardant, and with low emission of smoke and toxic gases.
  • High Environmental Resistance: Robust and mud-resistant outer cover, ideal for harsh offshore environments.
  • Superior Water Protection: Dual system with tapes and fillers that block water from entering both longitudinally and transversely.
  • Halogen-free: It does not emit corrosive gases in case of fire, protecting electronic equipment and structures.
  • High Durability: Internal lining in SHF2/SHF MUD and external lining in polyurethane for maximum mechanical protection.
  • Reliable Power Transmission: Designed specifically for fixed medium voltage (6/10kV) installations.
  • High Performance Insulation: Composed of mica tape and XLPE, ensuring superior electrical integrity.
  • Operation in Extreme Temperatures: Safe operating range from -20°C to +90°C, suitable for various weather conditions.
  • Mechanical Robustness: Shielding with tinned copper wire mesh that protects against impacts and interference.
  • Compliance with Standards: It meets stringent industry standards, such as NEK 606 and various IEC standards.

Applications

  • Oil and Gas Platforms: Power supply for critical drilling, production, and processing systems.
  • Ships and Vessels: Power distribution in fixed installations on board different types of ships.
  • Floating Production Storage and Offloading (FPSO) Units: Power supply for process modules, generation and accommodations.
  • Shipyards and Port Terminals: Power circuits for cranes, gantries and other heavy machinery.
  • Offshore Drilling Systems: Connection of electric motors and mud pumps operating in environments with debris.
  • Naval and Maritime Industry: Fixed electrical installations in environments with high humidity and exposure to sea air.
  • Power Generation Modules: Interconnection of medium voltage generators and main distribution panels.
  • Deck Equipment: Power supply for winches, pumps, and anchoring and positioning systems.
  • Offshore Substations: Used in renewable energy installations, such as offshore wind farms.
  • Heavy Industrial Applications: Fixed installations that require high resistance to oils, chemicals, and abrasion.
TECHNICAL DATA
General information
Product typeOffshore & Marine Cables NEK606 with P7 or P7/P14 BFOU water locking. HydroCore®
ApplicationsFixed installation for medium voltage power. They are partially sealed against water, fire resistant, flame retardant, low smoke emission, halogen free and mud resistant.
Electrical Parameters
Operating Voltage6/10 kV or 8.7/15 kV, depending on the cross-section.
Maximum DC Resistance of the Conductor at 20°CIt varies from 0,734 Ω/km (for 25 mm²) to 0,0286 Ω/km (for 630 mm²).
DC Capacity at 45°C (1 core)It ranges from 127 A (for 25 mm²) to 890 A (for 630 mm²).
DC Capacity at 45°C (3 cores)It ranges from 89 A (for 25 mm²) to 623 A (for 630 mm²).
Short-Circuit Current (1s)It ranges from 3580 A (for 25 mm²) to 90140 A (for 630 mm²).
Product Design
Conductor MaterialTin-plated, stranded and annealed copper, class 2, according to IEC 60228.
Driver's ScreenSemiconductor material.
InsulationHalogen-free Mica + XLPE tape (Lower losses, higher dielectric strength, greater robustness and durability).
Isolation ScreenSemiconductor material and tinned copper wire mesh.
FillFill with water-blocking seals, if necessary.
Separator (Bedding)Halogen-free compound. PETP tape can be applied over the separator.
ArmorTin-plated copper wire mesh. PETP tape can be applied over the mesh.
Water Blocking ElementsWater-blocking tape and wires for longitudinal sealing.
Inner LayerHalogen-free thermoset compound, SHF2 (for TYPE P7), or halogen-free and mud-resistant thermoset compound, SHF MUD (for TYPE P7/P14), in red.
Outer CoverPolyurethane for watertightness across the surface. PE is optional, but does not meet the low smoke emission standard.
Cable FormatRound
Product characteristics
Fire resistantYes, in accordance with IEC 60331-21.
Flame RetardantYes, in accordance with IEC 60332-1.
Reduced Fire SpreadYes, in accordance with IEC 60332-3-22.
Halogen-freeYes, in accordance with IEC 60754-1,2.
Low Smoke EmissionYes, in accordance with IEC 61034-1,2.
Mud ResistantYes (for type P7/P14).
Minimum Radius of Curvature15 x outer diameter (during installation); 9 x outer diameter (after fixed installation).
Temperature Range-20 ° C to + 90 ° C.
Applicable Standards
NEK 606IEC 60092-354
IEC 60092-360IEC 60331-21 (Circuit integrity)
IEC 60332-1 (Flame retardancy)IEC 60332-3-22 (Reduced fire spread)
IEC 60754-1,2 (Halogen-free)IEC 61034-1,2 (Low smoke emission)
IEC 60228 Class 2 (Conductors)VG 95218 part 29 (Leak tightness)
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area in mm²)Nominal Insulation Thickness (mm)Nominal Coating Thickness (mm)Nominal Thickness of the Inner Sheath (mm)Nominal Thickness of the Outer Sheath (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)Nominal Conductor Diameter (mm)Maximum DC Resistance @ 20°C (Ω/km)Rated Direct Current @ 45°C 1 Conductor (A)Rated Direct Current @ 45°C 3 Conductors (A)Short-Circuit Current 1s (A)Operating Voltage (KV)
1 x 163.41.51.21.027.6±2 1040
1 x 253.41.61.21.229.5±2 12086.57341278935806/10
1 x 353.41.71.21.230.9±2 13867.452915711050106/10
1 x 503.41.71.31.232.3±2 15758.739119613771506/10
1 x 703.41.81.31.234.3±2 190110.30.27242169100206/10
1 x 953.41.81.41.436.8±2 226812.2195293205135906/10
1 x 1203.41.91.41.438.9±2 274113.8154339237171706/10
1 x 1503.42.01.51.440.9±2 314015.1126389272214606/10
1 x 1853.42.01.51.442.7±2 361217.00.1444311264706/10
1 x 2403.42.21.61.646.3±2 438919.6762522365343406/10
1 x 3003.42.31.71.649.1±2 517721.9607601421429306/10
3 x 163.42.41.81.052.2±2 3969
3 x 253.42.51.81.255.6±2 4599896/10
3 x 353.42.61.91.258.8±2 52921106/10
3 x 503.42.72.01.261.7±2 60271376/10
3 x 703.42.92.11.266.1±2 72451696/10
3 x 953.43.12.21.471.2±2 86842056/10
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.