Maritimus® Marine Instrumentation and Control Cable; Multipair / Multitern; Armored; Max. 1,50mm²; 150/250V; 1 to 37 pairs / terns; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092, 60331

MariTimus® Marine Instrumentation and Control Cable, Multipair/Multi-core, 150/250V, MICA/XLPE/SHF1 (LSOH), Armored and Fire Resistant

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

MariTimus® Fireproof Instrumentation and Control CablesDesigned for maximum safety in fixed installations aboard ships and offshore platforms, these cables guarantee the integrity of your critical systems. MariTimus cable offers robust construction, fire resistance, and reliable communication, making it the ideal choice for safety, control, and instrumentation circuits where failure is not an option.
  • Maximum Fire Safety: Constructed with mica tape and XLPE insulation, it is fire-resistant, flame-retardant, and halogen-free, ensuring safe evacuation and business continuity.
  • Interference-Free Communication: Shielding with tinned copper wire braid protects against electromagnetic interference, ensuring accurate and reliable data transmission for your instruments.
  • Robust and Secure Installation: The tinned copper braid armor and LSOH outer sheath (SHF1) offer excellent mechanical protection and strength in harsh marine environments.
  • Compliance with International Standards: Fully compliant with the stringent IEC 60092, 60331, 60332, 60754 and 61034 standards, attesting to its superior quality for naval applications.
  • Durability in Extreme Conditions: Designed to operate reliably across a wide temperature range, from -30°C to +90°C, ensuring consistent performance wherever it is installed.
PRODUCT DESIGN
  • Conductors: Class 5 stranded tinned copper conductor. Bare copper or Class 2 conductor can be supplied upon request.
  • Insulation: Mica tape + XLPE
  • Wiring Element: Pair/Trio
  • Inner Covering: Overlaid polyester tape
  • Armor: Tinned copper wire mesh. Bare copper available upon request.
  • Outer sheath: LSOH (SHF1). SHF2 upon request.
  • Outer Cover Color: Orange
DETAILS

Benefits

  • Maximum Fire Safety: Designed with mica tape and XLPE insulation to maintain circuit integrity during a fire.
  • Fire Protection: Flame-retardant properties that help minimize the spread of fires on board.
  • A Safer Environment: Composed of low smoke emission and halogen-free (LSOH) material, essential for confined areas.
  • High Mechanical Durability: Armor with a tinned copper wire mesh that offers robust protection against impacts and crushing.
  • Reliable Signal Transmission: Tinned copper shielding is effective against electromagnetic interference, ensuring signal quality.
  • Wide Operating Range: Safe and reliable performance in temperatures ranging from -30°C to +90°C.
  • Quality Assurance: Built in accordance with stringent international standards IEC 60092, 60331, 60332 and others.
  • Installation Flexibility: Class 2 stranded copper conductors that facilitate handling and installation in fixed locations.
  • Superior Electrical Insulation: The combination of mica tape and XLPE provides excellent insulation characteristics.
  • Resistance and Protection: It has an SHF1 outer coating, with the option of SHF2 available upon request for greater chemical protection.

Applications

  • Naval and Offshore Installations: Ideal for general use aboard ships, oil platforms and other maritime vessels.
  • Critical Safety Circuits: Essential in emergency circuits where fire resistance is a fundamental requirement.
  • Passenger Ships: It guarantees maximum safety on cruise ships, ferries, and other passenger transport vessels.
  • Instrumentation Systems: High-reliability connection for sensors, meters, and monitoring equipment.
  • Onboard Control Systems: Used for machinery control, automation, and processes on commercial vessels.
  • Communications and Navigation: It is used in vital systems on the control bridge and in communication equipment.
  • Emergency Lighting: Ensures the supply of power to essential lighting systems during an evacuation.
  • Fire Alarm and Detection System: Perfect for powering smoke detection systems and fire alarms.
  • Commercial Vessels: Robust applications in cargo ships, tankers, tugboats and other work vessels.
  • Various Fixed Installations: Suitable for any fixed onboard installation requiring secure, fire-resistant cables.
TECHNICAL DATA
General information
BrandInnovcable
Product typeFire-resistant armored instrumentation and control cables (multipair/multi-strand).
CórdobaMariTimus® 150/250V
Electrical Parameters
Nominal Voltage150 / 250V
Product Design
Conductor MaterialTin-plated stranded copper conductor, Class 5. Bare copper and/or Class 2 available upon request.
InsulationMica tape + XLPE.
Torsion ElementSuit/Pair.
Internal CoverageOverlapping polyester tape.
ArmorBraided copper wire.
External CoverLSOH (SHF1). SHF2 can be offered upon request.
Cover ColorOrange.
Driver IdentificationPair: White/blue, numbered sequentially.

Suit: White/blue/red numbered sequentially.

Product characteristics
Application AreaUsed on board ships in all locations for fixed installations in safety circuits where fire resistance is required. Suitable for installation on passenger ships and other commercial vessels.
Fire resistanceYes.
Flame retardantYes.
Smoke EmissionLow smoke emission and halogen-free.
Halogen-freeYes.
Minimum Bending Radius (Fixed Installation)6 x Outer Diameter.
Temperature Range-30 ° C to + 90 ° C.
Applicable Standards
IEC 60092-350/351/376/359IEC 60331-21
IEC 60332-1IEC 60332 3 22
IEC 60754-1/2IEC 61034
DIMENSIONAL TABLE
Construction (Number of elements x Number of tracks per element x Cross-sectional area (mm²))Nominal Insulation Thickness (mm)Nominal Coating Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1×2×0.750.51.39.1120
2×2×0.750.51.310.2150
3×2×0.750.51.814.6280
4×2×0.750.51.815.4320
5×2×0.750.51.917.2390
6×2×0.750.51.918.3440
7×2×0.750.51.918.3460
8×2×0.750.52.019.6520
10×2×0.750.52.021.7620
12×2×0.750.52.122.8700
14×2×0.750.52.123.6770
16×2×0.750.52.225.4870
19×2×0.750.52.227.0990
20×2×0.750.52.227.01010
24×2×0.750.52.430.91240
30×2×0.750.52.533.51480
37×2×0.750.52.635.91730
1×2×1.00.51.39.5130
2×2×1.00.51.310.7170
3×2×1.00.51.815.3320
4×2×1.00.51.816.2360
5×2×1.00.51.918.1440
6×2×1.00.52.019.5510
7×2×1.00.52.019.5530
8×2×1.00.52.020.7590
10×2×1.00.52.123.2730
12×2×1.00.52.124.1810
14×2×1.00.52.225.1900
16×2×1.00.52.226.91010
19×2×1.00.52.328.81160
20×2×1.00.52.328.81190
24×2×1.00.52.533.01460
30×2×1.00.52.635.81740
37×2×1.00.52.938.82140
1×2×1.50.61.310.5160
2×2×1.50.61.412.1220
3×2×1.50.61.917.4400
4×2×1.50.61.918.4470
5×2×1.50.62.020.6570
6×2×1.50.62.122.2660
7×2×1.50.62.122.2700
8×2×1.50.62.123.6780
10×2×1.50.62.226.5950
12×2×1.50.62.327.71070
14×2×1.50.62.328.71180
16×2×1.50.62.431.01350
19×2×1.50.62.533.21560
20×2×1.50.62.533.21590
24×2×1.50.62.938.52060
30×2×1.50.63.041.82450
37×2×1.50.63.144.72880
1×3×0.750.51.39.5130
2×3×0.750.51.814.9290
3×3×0.750.51.815.7340
4×3×0.750.51.917.2410
5×3×0.750.51.918.8480
6×3×0.750.52.021.2590
7×3×0.750.52.021.2620
8×3×0.750.52.122.8700
10×3×0.750.52.225.7860
12×3×0.750.52.227.0970
14×3×0.750.52.328.31080
16×3×0.750.52.329.91200
19×3×0.750.52.432.31390
20×3×0.750.52.533.01460
24×3×0.750.52.635.91710
30×3×0.750.52.940.12170
32×3×0.750.53.041.72320
1×3×1.00.51.39.9150
2×3×1.00.51.815.6320
3×3×1.00.51.816.5380
4×3×1.00.51.918.1470
5×3×1.00.52.020.1560
6×3×1.00.52.122.6680
7×3×1.00.52.122.6720
8×3×1.00.52.124.1810
10×3×1.00.52.227.2990
12×3×1.00.52.328.81130
14×3×1.00.52.330.01260
16×3×1.00.52.431.91410
19×3×1.00.52.534.41640
20×3×1.00.52.535.01700
24×3×1.00.52.938.82110
30×3×1.00.53.042.82560
32×3×1.00.53.144.42730
1×3×1.50.61.311.0180
2×3×1.50.61.917.7410
3×3×1.50.61.918.7490
4×3×1.50.62.020.6610
5×3×1.50.62.122.9740
6×3×1.50.62.225.8890
7×3×1.50.62.225.8950
8×3×1.50.62.327.71070
10×3×1.50.62.431.31320
12×3×1.50.62.533.21520
14×3×1.50.62.534.61690
16×3×1.50.62.837.31990
19×3×1.50.62.940.32310
20×3×1.50.63.041.12420
24×3×1.50.63.144.72840
30×3×1.50.63.349.53460
32×3×1.50.63.351.23670
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.