Maritimus® Naval Instrumentation and Control Cable; Multipair / Multi-Tension; Max. 1,50mm²; 150/250V; 2 to 37 pairs / terns; MICA / XLPE / ZH / SHF1; Fire Resistant; +90°C; IEC 60092, 60331

MariTimus® Marine Instrumentation and Control Cable, Multipair/Multi-Strand, 150/250V, MICA/XLPE/ZH/SHF1 (LSOH), Fully Shielded and Armored, Fire Resistant

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

MariTimus® Fire-Resistant Instrumentation and Control CablesDesigned for maximum safety on ships and offshore platforms. Ensures the integrity of critical control circuits, even under fire, protecting lives and equipment with superior reliability in any emergency.
  • Maximum Fire Safety: It maintains the integrity of vital circuits, ensuring the continuity of security operations.
  • Low Smoke and Zero Halogen (LSOH): It protects lives during evacuations and preserves electronic equipment.
  • Robustness and Durability: Copper braid armor for superior protection against impacts and crushing.
  • Clean and Reliable Signal: Shielding against electromagnetic interference for flawless data transmission.
  • Certified Naval Application: Complies with IEC 60092 and 60331 standards for installation on any vessel, including passenger ships.
PRODUCT DESIGN
  • Conductors: Copper conductor. Tinned braided copper conductor, Class 5. Bare copper conductor or Class 2 can be supplied upon request.
  • Insulation: Mica tape + XLPE insulation
  • Overall shielding: Aluminum/polyester tape with tinned copper drain wire.
  • Inner lining: Overlaid polyester tape
  • Armor: Tinned copper wire mesh. Bare copper available upon request.
  • Outer sheath: LSOH (SHF1). SHF2 upon request.
  • Road Identification:
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

  • Outer Sheath: Orange (International standard for visual identification of fire-resistant circuits) Fire ResistantFor intrinsically safe (IS) circuits, the outer sheath must be blue (subject to consultation).
DETAILS

Benefits

  • Fire Safety: Constructed with fire-resistant, flame-retardant, low-smoke, and halogen-free materials.
  • Circuit Integrity: Mica tape and XLPE insulation ensures continued operation of safety circuits during fires.
  • Electromagnetic Protection: The overall shielding with aluminum/polyester tape and drain protects against external interference.
  • Superior Mechanical Strength: Tin-plated copper wire braid armor that offers robust protection against physical damage.
  • Durable Coating: External sheathing in LSOH (SHF1), ideal for marine and offshore environments.
  • Wide Temperature Range: It operates safely in temperatures ranging from -30°C to +90°C, adapting to various conditions.
  • Installation Flexibility: It has a bending radius that facilitates assembly in locations with limited space.
  • Compliance with Strict Standards: It meets multiple IEC standards, ensuring international quality and reliability.
  • Clear Identification: Pairs and trios identified by colors and numbers to simplify installation and maintenance.
  • High Reliability: Designed for fixed installations that require maximum safety and continuous performance.

Applications

  • Naval and Offshore Installations: Ideal for use on board ships, oil platforms and other maritime structures.
  • Critical Safety Circuits: Used in emergency systems where fire resistance is a fundamental requirement.
  • Passenger Ships: Suitable for installation on cruise ships and ferries due to its low emission of smoke and toxic gases.
  • Commercial Vessels: Suitable for instrumentation and control systems on cargo ships and other vessels.
  • Alarm and Detection Systems: Used in fire detection circuits and alarm systems that need to operate during emergencies.
  • Control and Instrumentation: Connecting sensors, meters, and control devices in marine industrial environments.
  • Areas with High Security Requirements: Perfect for locations where protecting human life and equipment is a priority.
  • Fixed Installations Onboard: Designed specifically for fixed applications in all areas of a vessel.
  • Naval Automation: Reliability for automated control systems in machine rooms and control bridges.
  • Shipbuilding Projects: Used in new construction and refurbishment of vessels that comply with IEC standards.
TECHNICAL DATA
General information
BrandInnovcable
Product SeriesMariTimus® Fire Resistant Instrumentation & Control Cables
Product typeFire-resistant, shielded and armored instrumentation and control cables (multipair/multitriple), for offshore and marine applications.
CórdobaMariTimus® Fire Resistant Line
Electrical Parameters
Rated voltage150 / 250V
Product Design
Conductor MaterialBraided tin-plated copper. Bare copper available upon request.
Driver ClassClass 5. Class 2 available upon request.
InsulationMica tape + XLPE insulation.
Torsion ElementPair / Trio / Quad
Road Identification
  • Pair: Black and Light Blue

  • Suit (Trio): Black, Light Blue, and Brown.

General ArmoringAluminum/polyester tape.
Drainage WireTinned copper wire.
Internal CoverageOverlapping polyester tape.
ArmorBraided tinned copper wire. Bare copper available upon request.
Exterior Roofing MaterialLSOH (SHF1). SHF2 can be offered upon request.
Outer Cover Color
  • Outer Sheath: Orange (International standard for visual identification of fire-resistant circuits) Fire ResistantFor intrinsically safe (IS) circuits, the outer sheath must be blue (subject to consultation).
Mechanical and Thermal Characteristics
Application AreaFixed installations on board ships in all locations, especially in safety circuits where fire resistance is required. Suitable for passenger ships and other commercial vessels.
Minimum Bending Radius (Fixed Installation)6 x Outer Diameter
Temperature Range-30 ° C to + 90 ° C.
Fire resistantYes.
Flame RetardantYes.
Halogen-freeYes.
Low Smoke EmissionYes.
Applicable Standards
General ConstructionIEC 60092-350, IEC 60092-351, IEC 60092-376, IEC 60092-359
Fire resistanceIEC 60331-21
Flame RetardantIEC 60332-1, IEC 60332-3-22
Halogen EmissionIEC 60754-1/2
Smoke EmissionIEC 61034
DIMENSIONAL TABLE
Construction (Number of elements x Number of conductors in the element x Cross-sectional area (mm²))Nominal Insulation Thickness (mm)Nominal Sheath Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1×2×0.750.51.19.3120
2×2×0.75∗0.51.110.5
3×2×0.750.51.314.8260
4×2×0.750.51.315.6300
7×2×0.750.51.418.6430
8×2×0.750.51.519.9480
10×2×0.750.51.622.4580
12×2×0.750.51.623.2640
14×2×0.750.51.624.0710
16×2×0.750.51.725.9800
19×2×0.750.51.727.0890
24×2×0.750.51.930.81110
30×2×0.750.52.034.41350
32×2×0.750.52.034.91410
37×2×0.750.52.137.31680
1×2×1.00.51.19.7130
2×2×1.0∗0.51.110.9170
3×2×1.00.51.315.5300
4×2×1.00.51.316.4340
7×2×1.00.51.519.8500
8×2×1.00.51.521.0560
10×2×1.00.51.623.6660
12×2×1.00.51.624.5740
14×2×1.00.51.725.6830
16×2×1.00.51.827.6940
19×2×1.00.51.828.81060
24×2×1.00.51.932.61300
30×2×1.00.52.137.11690
32×2×1.00.52.137.71770
37×2×1.00.52.239.71990
1×2×1.50.61.110.5150
2×2×1.5∗0.61.212.1220
3×2×1.50.61.417.2360
4×2×1.50.61.418.2420
7×2×1.50.61.521.8620
8×2×1.50.61.623.4700
10×2×1.50.61.726.3840
12×2×1.50.61.727.3940
14×2×1.50.61.828.51060
16×2×1.50.61.930.81200
19×2×1.50.61.932.11350
24×2×1.50.62.137.11780
30×2×1.50.62.341.62180
32×2×1.50.62.342.32280
37×2×1.50.62.444.52570
1×3×0.750.51.19.7130
2×3×0.750.51.315.0270
3×3×0.750.51.315.8320
4×3×0.750.51.417.4390
7×3×0.750.51.521.5590
8×3×0.750.51.623.1660
10×3×0.750.51.726.1790
12×3×0.750.51.827.7900
14×3×0.750.51.828.81000
16×3×0.750.51.930.71130
19×3×0.750.52.033.11300
24×3×0.750.52.137.11680
30×3×0.750.52.341.12040
32×3×0.750.52.342.52150
37×3×0.750.52.444.72420
1×3×1.00.51.110.2150
2×3×1.00.51.315.9310
3×3×1.00.51.417.0380
4×3×1.00.51.418.5450
7×3×1.00.51.623.1690
8×3×1.00.51.624.6770
10×3×1.00.51.828.0930
12×3×1.00.51.829.51050
14×3×1.00.51.930.91190
16×3×1.00.51.932.71320
19×3×1.00.52.035.41530
24×3×1.00.52.239.91990
30×3×1.00.52.444.22420
32×3×1.00.52.445.72560
37×3×1.00.52.548.02870
1×3×1.50.61.111.0180
2×3×1.50.61.417.5370
3×3×1.50.61.418.5450
4×3×1.50.61.520.4560
7×3×1.50.61.725.5870
8×3×1.50.61.727.2970
10×3×1.50.61.931.01170
12×3×1.50.61.932.71340
14×3×1.50.62.034.31510
16×3×1.50.62.137.01800
19×3×1.50.62.239.92080
24×3×1.50.62.444.42560
30×3×1.50.62.649.23110
32×3×1.50.62.650.93300
37×3×1.50.62.753.43710
* 2 pairs are assembled as a quad
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.