Maritimus® Marine Instrumentation and Control Cable; Multipair / Multitern (PiMF/TiMF); Individual Shielding; Armored; Max. 1,50mm²; 150/250V; 1 to 37 pairs / terns; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092, 60331

MariTimus® Marine Instrumentation and Control Cable, Multipair/Multicore (PiMF/TiMF), 150/250V, Mica/XLPE/SHF1 (LSOH), Individually Shielded and Armored, Fire Resistant

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

MariTimus® Naval Cable: Safety and Reliability for Critical SystemsDesigned for critical conditions aboard ships, this cable ensures the integrity of control systems. Its advanced construction combines fire resistance and superior shielding, guaranteeing maximum reliability and safety in operations.
  • Superior Fire Resistance: Mica tape keeps vital circuits operating even under intense fire.
  • Signal of High Integrity: Individual shielding eliminates interference and ensures data accuracy.
  • Robust Mechanical Protection: Tinned copper armor protects conductors against impacts, abrasion, and crushing.
  • Crew Safety: LSOH lining does not generate toxic fumes, facilitating evacuation in emergencies.
  • Quality Assurance: Certified according to IEC 60092 naval standards, guaranteeing total reliability and performance.
PRODUCT DESIGN
  • Conductors: Class 5 stranded tinned copper conductor. Bare copper conductor and/or Class 2 can be supplied upon request.
  • Insulation: Mica tape + XLPE.
  • Cabling Element: Pair/Triple.
  • Individual Shielding: Aluminum/Polyester Tape.
  • Drain wire: Tinned copper wire.
  • Inner Covering: Overlaid polyester tape.
  • Armor: Tinned copper wire mesh. Bare copper available upon request.
  • External Coating: LSOH (SHF1). SHF2 can be offered upon request.
  • Core identification (Pair): White/blue, numbered sequentially.
  • Core identification (Suit): White/blue/red numbered sequentially.
  • Outer cover color: Orange.
DETAILS

Benefits

  • Maximum Fire Safety: Fire-resistant, low-smoke, halogen-free (LSOH) cables.
  • High Mechanical Protection: Armor with tinned copper braid that offers robustness against impacts and crushing.
  • Signal Integrity: Individual shielding with aluminum/polyester tape that protects against electromagnetic interference.
  • High Durability: Mica tape and XLPE insulation, ideal for harsh marine and offshore environments.
  • Reliability in Critical Circuits: Designed for safety circuits that need to operate even during fires.
  • Wide Temperature Range: Stable operation in temperatures ranging from -30°C to +90°C.
  • International Compliance: It meets stringent IEC standards, guaranteeing a superior level of quality and safety.
  • Flame Retardant Construction: It minimizes the risk of fire spreading in onboard installations.
  • Safety for Human Lives: Low-smoke technology facilitates evacuation in case of emergency.
  • Secure Fixed Installation: Class 5 tinned copper conductors for a reliable and long-lasting electrical connection.

Applications

  • Passenger Ships: Installations in common areas, cabins, and emergency systems where safety is vital.
  • Commercial Vessels: Used on cargo ships, tankers, and bulk carriers for control and instrumentation.
  • Offshore Platforms: Connecting equipment in oil and gas units, designed to withstand harsh environments.
  • Alarm and Security Systems: Power supply for fire detection circuits, alarms, and communication systems.
  • Machine Control Rooms: Data transmission from sensors and actuators for propulsion and generator monitoring.
  • Onboard Automation: Interconnection of PLCs and control systems for process automation on ships.
  • Navigation Systems: Connection of essential navigation and control equipment on the bridge.
  • Emergency Lighting: Ensures the operation of lighting circuits in escape routes during a fire.
  • Control and Distribution Panels: Internal wiring of electrical panels for power distribution and control.
  • Shipbuilding Industry in General: A versatile solution for fixed installations on any type of vessel requiring high performance.
TECHNICAL DATA

 

General information
BrandInnovcable
Product typeFire-Resistant Instrumentation and Control Cables for Marine and Offshore Applications (Multipair/Multicore)
CórdobaMariTimus® PIMF/TIMF
Electrical Parameters
Rated voltage150 / 250V
Product Design
Conductor MaterialBraided tin-plated copper. Bare copper available upon request.
Driver ClassClass 5. Class 2 available upon request. Compliant with applicable standards.
InsulationMica Tape + XLPE (Crosslinked Polyethylene)
Cabling ElementPair or Trio
Individual ProtectionAluminum/Polyester tape with tinned copper drain wire
Internal CoverageOverlaid Polyester Tape
ArmorTinned copper wire braid
Exterior Roofing MaterialLSOH (SHF1). SHF2 compound available upon request.
Road Identification
  • By: White/Blue, numbered sequentially.
  • Suit: White/Blue/Red, numbered sequentially.
Product characteristics
Application AreaFixed installations on board ships in all locations, especially in safety circuits where fire resistance is required. Suitable for passenger ships and other commercial vessels.
Fire resistanceYes
Flame RetardantYes
Halogen-free and low smoke emission.Yes (LSOH)
Mechanical and Thermal Properties
Minimum Bending Radius (Fixed Installation)6 x Outer Diameter
Temperature Range (Fixed Installation)-30 ° C to + 90 ° C
Applicable Standards
Design and ConstructionIEC 60092-350, IEC 60092-351, IEC 60092-376, IEC 60092-359
Fire resistanceIEC 60331-21
Flame RetardantIEC 60332-1, IEC 60332-3-22
Halogen Gas EmissionIEC 60754-1/2
Smoke EmissionIEC 61034
Product Variations (Dimensions and Weights)
This product is available in multiple pair and triple configurations, with different cross-sections (e.g., 0.75 mm², 1.0 mm², 1.5 mm²). The insulation thickness, sheath thickness, overall diameter, and nominal weight vary according to the specific cable construction.

 

DIMENSIONAL TABLE
Nominal Insulation Thickness (mm)Nominal Sheath Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1×2×0.750.51.39.3130
2×2×0.750.51.413.6230
3×2×0.750.51.815.1320
4×2×0.750.51.816.0370
5×2×0.750.51.917.9450
6×2×0.750.51.919.1510
7×2×0.750.51.919.1540
8×2×0.750.52.020.4610
10×2×0.750.52.122.9740
12×2×0.750.52.123.7830
14×2×0.750.52.124.6910
16×2×0.750.52.226.51040
19×2×0.750.52.328.41200
20×2×0.750.52.328.41230
24×2×0.750.52.432.31490
30×2×0.750.52.535.11790
37×2×0.750.52.838.12200
1×2×1.00.51.39.7140
2×2×1.00.51.815.0300
3×2×1.00.51.815.9360
4×2×1.00.51.917.0430
5×2×1.00.51.918.8510
6×2×1.00.52.020.3600
7×2×1.00.52.020.3630
8×2×1.00.52.021.5700
10×2×1.00.52.124.1860
12×2×1.00.52.225.2980
14×2×1.00.52.226.11080
16×2×1.00.52.328.21230
19×2×1.00.52.330.01410
20×2×1.00.52.330.01450
24×2×1.00.52.534.41780
30×2×1.00.52.837.82220
37×2×1.00.52.940.52620
1×2×1.50.61.310.7170
2×2×1.50.61.916.9380
3×2×1.50.61.917.9450
4×2×1.50.61.919.0530
5×2×1.50.62.021.3650
6×2×1.50.62.123.0750
7×2×1.50.62.123.0800
8×2×1.50.62.124.4890
10×2×1.50.62.327.61110
12×2×1.50.62.328.71250
14×2×1.50.62.329.71380
16×2×1.50.62.432.11580
19×2×1.50.62.534.41820
20×2×1.50.62.534.41870
24×2×1.50.62.939.92400
30×2×1.50.63.043.32870
37×2×1.50.63.246.63410
1×3×0.750.51.39.7140
2×3×0.750.51.815.4320
3×3×0.750.51.816.2380
4×3×0.750.51.917.9460
5×3×0.750.52.019.8560
6×3×0.750.52.122.2670
7×3×0.750.52.122.2710
8×3×0.750.52.123.7800
10×3×0.750.52.226.7980
12×3×0.750.52.328.31120
14×3×0.750.52.329.41240
16×3×0.750.52.431.41400
19×3×0.750.52.533.91620
20×3×0.750.52.534.41680
24×3×0.750.52.837.92070
30×3×0.750.53.042.02520
32×3×0.750.53.043.42670
1×3×1.00.51.310.1160
2×3×1.00.51.816.1360
3×3×1.00.51.917.3440
4×3×1.00.51.918.8530
5×3×1.00.52.020.8640
6×3×1.00.52.123.4770
7×3×1.00.52.123.4820
8×3×1.00.52.225.2930
10×3×1.00.52.328.41150
12×3×1.00.52.329.91310
14×3×1.00.52.431.31470
16×3×1.00.52.533.41660
19×3×1.00.52.836.52010
20×3×1.00.52.837.12090
24×3×1.00.52.940.32450
30×3×1.00.53.144.73000
32×3×1.00.53.146.23180
1×3×1.50.61.411.4200
2×3×1.50.61.918.2450
3×3×1.50.62.019.5560
4×3×1.50.62.021.3670
5×3×1.50.62.123.6820
6×3×1.50.62.226.6990
7×3×1.50.62.226.61060
8×3×1.50.62.328.61200
10×3×1.50.62.432.31480
12×3×1.50.62.534.31700
14×3×1.50.62.635.91920
16×3×1.50.62.938.82260
19×3×1.50.63.041.82620
20×3×1.50.63.042.52720
24×3×1.50.63.146.23200
30×3×1.50.63.351.23910
32×3×1.50.63.453.24180
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.