Maritimus® Medium Voltage Marine Power Cable; Shielded and Armored; Max. 300,00 mm²; 3.6/6 kV, 6/10 kV, 8.7/15 kV; 1 and 3 conductors; XLPE / SHF1; Flame Retardant; +90°C; IEC 60092

MariTimus® Medium Voltage Marine Cable 3.6/6kV, 6/10kV, 8.7/15kV XLPE/SHF1 Shielded and Armored (steel), Flame Retardant

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

MariTimus® Marine Cable: Maximum Safety for Offshore ApplicationsDesigned for the harshest conditions in fixed installations aboard ships and platforms. This cable ensures maximum protection and performance, combining robust construction with cutting-edge technology to protect lives and equipment in critical environments.
  • Superior Fire Safety: Flame retardant, low smoke and halogen-free for maximum protection.
  • Armored and Robust Construction: Armor with braided galvanized steel wire protects against mechanical impacts.
  • High Electrical Performance: Copper conductors and XLPE insulation for reliable power transmission.
  • Resistance to Extreme Environments: It operates with complete safety over a wide temperature range, from -30°C to +90°C.
  • Ideal for Naval and Offshore Use: Designed for fixed installations on ships, it complies with stringent international IEC standards.
PRODUCT DESIGN
  • Conductors: Class 2 bare stranded copper conductor. Can be manufactured in tin-plated copper upon request.
  • Conductor Screen: Semiconductor layer (tape/composite).
  • Insulation: XLPE.
  • Insulation screen: Semiconductor layer (tape/compound).
  • Metal Mesh: Copper tape.
  • Inner Sheath: LSOH (SHF1).
  • Armor: Braided galvanized steel wire.
  • Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request.
DETAILS

Benefits

  • High security: Composed of halogen-free (LSOH) material, ensuring low emission of smoke and toxic gases in case of fire.
  • Flame retardant: Built to meet stringent IEC 60332 standards, which minimizes fire spread and increases onboard safety.
  • Superior mechanical protection: Armor with braided steel wire offers excellent resistance against impacts and mechanical damage.
  • High performance insulation: XLPE insulation ensures optimal electrical properties and a long product lifespan.
  • Operation in various temperatures: Designed to operate reliably over a wide temperature range, from -30°C to +90°C.
  • Interference-free transmission: Shielding with copper tape effectively protects against electromagnetic interference, ensuring a clean signal.
  • Robust construction: It has an internal and external coating of LSOH (SHF1), providing greater durability in harsh marine environments.
  • Certified quality: In full compliance with international standards IEC 60092, specific to marine electrical installations.
  • Efficient conductivity: It uses class 2 stranded copper conductors to ensure maximum efficiency in power transmission.
  • Secure installation: Designed for fixed installations, providing reliability and reducing maintenance needs.

Applications

  • Naval and maritime installations: Ideal for fixed electrical installations in all locations on board ships and vessels.
  • Oil and gas platforms: Perfect for powering energy and control systems in offshore units, ensuring maximum safety.
  • Medium voltage systems: Used in 3.6/6kV, 6/10kV and 8.7/15kV power distribution circuits in marine environments.
  • Power and lighting circuits: It is used in the distribution of power for lighting and motive power systems on vessels.
  • Power supply for critical equipment: Securely connects control panels, engines, pumps, and other vital onboard systems.
  • Areas with high security requirements: Essential for use in locations where fire protection is a top priority.
  • Shipyards and ports: Used in the electrical infrastructure of shipyards, port terminals and docks.
  • Passenger and cargo ships: It ensures continuous and safe operation on cruise ships, cargo ships, tankers, and bulk carriers.
  • Naval engineering projects: A reliable solution for new shipbuilding, as well as for fleet upgrades and modernization.
  • Harsh marine environments: Its robust construction makes it ideal for withstanding harsh sea conditions, such as humidity and salinity.
TECHNICAL DATA
General information
BrandInnovcable MariTimus® Line
Product typeMedium voltage flame retardant cables for naval and offshore use (MTX 3.6/6kV, 6/10kV, 8.7/15kV).
Electrical Parameters
Nominal Voltage3.6/6kV, 6/10kV, 8.7/15kV
Product Design
Conductor MaterialBare braided copper, class 2. Can be manufactured in tin-plated copper upon request.
Driver's ScreenSemiconductor layer (tape/compound).
Insulation MaterialXLPE (Crosslinked Polyethylene).
Isolation ScreenSemiconductor layer (tape/compound).
Metal ScreenCopper tape.
Inner Cover MaterialLSOH (SHF1).
ArmorBraided galvanized steel wire.
Exterior Roofing MaterialLSOH (SHF1). SHF2 can be offered upon request.
Cover ColorNot specified.
Road IdentificationColored tape inserted under the metal screen. For 3 channels: Red, Yellow, Blue.
Product characteristics
Application AreaFixed installations on board ships, in all locations.
Flame retardantYes.
Halogen-freeYes.
Low smoke emissionYes.
Minimum Bending Radius (Fixed Installation)12 x Outer Diameter (single conductor); 9 x Outer Diameter (three-wire).
Operating Temperature-30 ° C to + 90 ° C.
Applicable Standards
IEC 60092-350Construction and testing of naval cables.
IEC 60092-351Power, control and instrumentation cables for electrical installations on ships.
IEC 60092-354Medium voltage cables for naval installations.
IEC 60092-359Requirements for insulation and sheathing materials for onboard electrical cables.
IEC 60332-1Testing of electrical and fiber optic cables under fire conditions - Part 1.
IEC 60332 3 22Test for vertical flame propagation of vertically mounted wires or cables - Category A.
IEC 60754-1/2Testing of gases produced during the combustion of cable materials.
IEC 61034Measuring the density of smoke from burning cables under defined conditions.
DIMENSIONAL TABLE
Voltage (kV)Construction (Number of conductors x Cross-section mm²)Nominal Insulation Thickness (mm)Nominal Thickness of Internal Cover (mm)Nominal Thickness of the External Cover (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
3.6/6 kV1 × 102.51.31.019.2560
3.6/6 kV1 × 162.51.31.020.1650
3.6/6 kV1 × 252.51.41.121.8800
3.6/6 kV1 × 352.51.41.123.0940
3.6/6 kV1 × 502.51.51.224.71120
3.6/6 kV1 × 702.51.61.226.71390
3.6/6 kV1 × 952.51.61.328.81720
3.6/6 kV1 × 1202.51.71.330.62020
3.6/6 kV1 × 1502.51.81.332.42350
3.6/6 kV1 × 1852.51.81.434.42780
3.6/6 kV1 × 2402.62.01.538.43580
3.6/6 kV1 × 3002.82.11.641.64310
3.6/6 kV3 × 102.51.91.436.31710
3.6/6 kV3 × 162.52.01.538.82030
3.6/6 kV3 × 252.52.11.642.02500
3.6/6 kV3 × 352.52.21.644.82950
3.6/6 kV3 × 502.52.31.748.03510
3.6/6 kV3 × 702.52.51.852.54420
6/10 kV1 × 163.41.41.122.3750
6/10 kV1 × 253.41.51.123.8890
6/10 kV1 × 353.41.21.525.21040
6/10 kV1 × 503.41.61.226.71220
6/10 kV1 × 703.41.61.228.51480
6/10 kV1 × 953.41.31.730.81830
6/10 kV1 × 1203.41.81.332.62140
6/10 kV1 × 1503.41.81.434.42470
6/10 kV1 × 1853.41.91.436.92990
6/10 kV1 × 2403.41.52.040.03680
6/10 kV1 × 3003.41.62.142.84390
6/10 kV3 × 163.41.62.143.12350
6/10 kV3 × 253.42.21.746.32840
6/10 kV3 × 353.41.72.349.13310
6/10 kV3 × 503.42.51.852.53910
6/10 kV3 × 703.41.92.656.84820
8.7/15 kV1 × 254.51.61.226.41030
8.7/15 kV1 × 354.51.21.627.61180
8.7/15 kV1 × 504.51.31.729.31370
8.7/15 kV1 × 704.51.71.331.11650
8.7/15 kV1 × 954.51.81.433.42010
8.7/15 kV1 × 1204.51.91.435.72410
8.7/15 kV1 × 1504.51.91.537.52760
8.7/15 kV1 × 1854.51.52.039.53200
8.7/15 kV1 × 2404.52.11.642.63910
8.7/15 kV1 × 3004.52.21.645.24610
8.7/15 kV3 × 254.51.82.451.63300
8.7/15 kV3 × 354.52.51.954.63820
8.7/15 kV3 × 504.52.61.957.64400
8.7/15 kV3 × 704.52.82.062.15370
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.