Maritimus® Medium Voltage Marine Power Cable; Shielded; Max. 300,00 mm²; 3.6/6 kV, 6/10 kV, 8.7/15 kV; 1 and 3 conductors; XLPE / SHF1; Flame Retardant; +90°C; IEC 60092

MariTimus® Medium Voltage Marine Cable 3.6/6kV, 6/10kV, 8.7/15kV; XLPE/SHF1 Shielded and Armored (copper), Flame Retardant

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

MariTimus® Naval CableMaximum Safety for Offshore and Maritime ApplicationsDesigned for the harshest conditions in fixed onboard installations, this medium-voltage cable is the ideal choice for reliable power. Its robust construction with advanced materials protects lives and equipment, meeting stringent international IEC standards for the marine sector.
  • Maximum Fire Safety: Flame retardant and halogen-free (LSOH), it minimizes toxic smoke and fire spread.
  • Highly Durable Construction: Copper braid armor offers superior mechanical protection, ensuring durability in harsh environments.
  • Exceptional Electrical Performance: Copper conductors and XLPE insulation ensure efficient and stable power transmission, even in extreme temperatures.
  • Versatility for Naval Installations: Ideal for all fixed installations on ships, optimizing projects and ensuring full compliance with standards.
  • Quality and Compliance Guaranteed: It strictly adheres to IEC standards (60092, 60332, 60754, 61034), synonymous with reliability and safety for its operation.
PRODUCT DESIGN
  • Conductors: Class 2 bare stranded copper conductor. Can be manufactured in tin-plated copper upon request.
  • Conductor Shielding: Semiconductor layer (tape/compound).
  • Insulation: XLPE.
  • Shielding of the insulation: Semiconductor layer (tape/compound).
  • Metal Shielding: Copper tape.
  • Internal Coating: Halogen-free compound.
  • Armor: Mesh of bare copper wires. Can be manufactured in tin-plated copper upon request.
  • External Coating: LSOH (SHF1). SHF2 can be offered upon request.
  • Identification of the Core Groups
  • Colored tape should be inserted under the metal shielding.
  • 3 cores: Red, Yellow, Blue.
DETAILS

Benefits

  • Onboard Safety: Low smoke emission and halogen-free (LSOH) material, essential for safety on ships.
  • Fire resistance: Flame retardant properties that meet IEC 60332-1 and IEC 60332-3-22 standards, minimizing the spread of fires.
  • Superior Insulation: XLPE insulation that guarantees excellent electrical and thermal performance in marine environments.
  • Robust Armor: Armor with braided tinned copper wires that provides mechanical protection and ensures signal integrity.
  • Structural Durability: Class 2 stranded copper conductors for greater flexibility and longer service life in fixed installations.
  • Electromagnetic Protection: Metallic shielding with copper tape to protect against external interference.
  • Wide Operating Range: Reliable performance in temperatures ranging from -30°C to +90°C, adapting to diverse conditions.
  • International Compliance: Designed in accordance with the stringent IEC 60092 standards for marine and offshore cables.
  • Versatile Installation: Suitable for all areas on board vessels, providing a unique and reliable solution.
  • Protective Coating: Halogen-free inner sheathing that increases conductor protection and overall cable safety.

Applications

  • Energy Systems: Power supply for main and secondary distribution panels in fixed onboard installations.
  • Engines and Propellers: Connection of medium voltage electric motors for propulsion systems and auxiliary machinery.
  • Deck Equipment: Power supply for cranes, winches and other load handling equipment.
  • Navigation Systems: Power supply for critical navigation and communication systems on vessels.
  • Offshore Platforms: For use in fixed electrical installations on oil and gas platforms, ensuring safety and reliability.
  • Passenger Ships: Power distribution in accommodation and service areas, where low smoke emission is crucial.
  • Cargo Vessels: Application in bulk carriers, tankers and container ships for lighting and power systems.
  • Military Ships: For use in naval vessels that require high-performance cables and compliance with safety standards.
  • Pumping Systems: Connection of ballast, sewage, and fire-fighting pumps throughout the vessel.
  • Floating Production Storage and Offloading (FPSO) Units: Power distribution in process modules and utilities in offshore units.
TECHNICAL DATA
General information
BrandInnovcable - MariTimus® Line
Product typeMedium voltage, shielded, flame retardant cables with XLPE insulation and LSOH (SHF1) sheathing for naval and offshore applications.
Electrical Parameters
Nominal Voltage3.6/6kV, 6/10kV, 8.7/15kV.
Product Design
Conductor MaterialClass 2 bare stranded copper conductor. Can be manufactured in tin-plated copper upon request.
Conductor ShieldingSemiconductor layer (tape/compound).
Base Material for Vein IsolationXLPE (Crosslinked Polyethylene).
Insulation ShieldingSemiconductor layer (tape/compound).
Metal ShieldingCopper tape.
Interior Cover MaterialHalogen-free compound.
ArmorBraided bare copper wire. Can be manufactured in tin-plated copper upon request.
Base Material for the External CoveringLSOH (SHF1). SHF2 available upon request.
Road IdentificationColored ribbons inserted under the metal shielding.
Road color code3 channels: Red, Yellow, Blue.
Product characteristics
Application AreaFor fixed installations on board ships in all areas.
Minimum Bending Radius (Fixed Installation)12 x Outer Diameter (single-core cable); 9 x Outer Diameter (three-core cable).
Operating Temperature-30 °C to +90 °C.
Flame retardantYes.
Halogen-freeYes.
Low smoke emissionYes.
Applicable Standards
Construction StandardIEC 60092-350/351/354/359.
Flame RetardantIEC 60332-1, IEC 60332-3-22.
Halogen EmissionIEC 60754-1/2.
Smoke EmissionIEC 61034.
DIMENSIONAL TABLE
TensãoConstruction (Number of conductors x Cross-sectional area mm²)Nominal Insulation Thickness (mm)Nominal Coating Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
3.6/6 kV1 x 102.51.519.6580
3.6/6 kV1 x 162.51.520.5670
3.6/6 kV1 x 252.51.521.8800
3.6/6 kV1 x 352.51.623.2940
3.6/6 kV1 x 502.51.624.51100
3.6/6 kV1 x 702.51.726.51380
3.6/6 kV1 x 952.51.828.61700
3.6/6 kV1 x 1202.51.930.42000
3.6/6 kV1 x 1502.51.932.02320
3.6/6 kV1 x 1852.52.034.42770
3.6/6 kV1 x 2402.62.138.03530
3.6/6 kV1 x 3002.82.341.24270
3.6/6 kV3 x 102.52.035.41620
3.6/6 kV3 x 162.52.238.42030
3.6/6 kV3 x 252.52.341.42470
3.6/6 kV3 x 352.52.444.22930
3.6/6 kV3 x 502.52.547.63510
3.6/6 kV3 x 702.52.751.94390
6/10 kV1 x 163.41.622.5750
6/10 kV1 x 253.41.623.8890
6/10 kV1 x 353.41.725.21040
6/10 kV1 x 503.41.726.51200
6/10 kV1 x 703.41.828.51480
6/10 kV1 x 953.41.930.61810
6/10 kV1 x 1203.41.932.22100
6/10 kV1 x 1503.42.034.42470
6/10 kV1 x 1853.42.136.92980
6/10 kV1 x 2403.42.239.83650
6/10 kV1 x 3003.42.342.44340
6/10 kV3 x 163.42.342.52330
6/10 kV3 x 253.42.445.92840
6/10 kV3 x 353.42.548.73310
6/10 kV3 x 503.42.751.93890
6/10 kV3 x 703.42.856.44820
8.7/15 kV1 x 254.51.726.21020
8.7/15 kV1 x 354.51.827.61170
8.7/15 kV1 x 504.51.828.91340
8.7/15 kV1 x 704.51.930.91630
8.7/15 kV1 x 954.52.033.42000
8.7/15 kV1 x 1204.52.035.02300
8.7/15 kV1 x 1504.52.137.32730
8.7/15 kV1 x 1854.52.239.33180
8.7/15 kV1 x 2404.52.342.23860
8.7/15 kV1 x 3004.52.445.24600
8.7/15 kV3 x 254.52.651.03280
8.7/15 kV3 x 354.52.753.83770
8.7/15 kV3 x 504.52.957.44430
8.7/15 kV3 x 704.53.061.55340
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.