Maritimus® Multicore Marine Power and Control Cable; Max. 95,00 mm²; 0,6/1 kV; 2 to 37 conductors; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331

MariTimus® Marine Multicore Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Fire Resistant IEC 60331

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

MariTimus® Fire Resistant Marine Cable: Maximum Safety for Maritime InstallationsDeveloped for the most demanding conditions in offshore and marine environments, this cable guarantees the integrity and continuity of operations. This multi-conductor cable has characteristics that make it the ideal choice, offering superior fire protection, low smoke emission, and absence of halogens, ensuring maximum protection for people and equipment on board.
  • Fire Safety: Construction using mica tape and XLPE insulation that is flame retardant and fire resistant.
  • Versatile and Safe Installation: Designed for fixed installations aboard ships in all locations where cable protection is not required.
  • High Performance and Durability: Composed of Class 5 stranded tinned copper conductors and LSOH (SHF1) outer sheath, ensuring flexibility and strength.
  • Environmental and Equipment Protection: Low smoke emission and absence of halogens (LSOH) protects sensitive electronic equipment and is safer for the crew in case of fire.
  • Wide Operating Range: Reliable performance across a wide temperature range, from -30°C to +90°C, suitable for diverse marine conditions.
PRODUCT DESIGN
  • Conductors: Class 5 stranded tinned copper conductor. Class 2 can be offered upon request.
  • Insulation: Mica tape + XLPE.
  • Outer sheath: LSOH (SHF1). SHF2 can be offered upon request.
  • Outer cover color: Orange. Other colors available upon request.
  • Road Identification according to CENELEC (HD 308 S2):
  • Two options: Brown, Blue.
  • Three options: Brown, Black, Gray.
  • Four colors: Blue, Brown, Black, Gray.
  • Five colors: Blue, Brown, Black, Gray, Black.
  • Multiple tracks: All tracks are black and sequentially numbered. Green/yellow tracks can be supplied upon request.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Blue, Brown.
  • Three-way + ground (4G): Green/Yellow, Brown, Black, Gray.
  • Four-way + ground (5G): Green/Yellow, Blue, Brown, Black, Gray.
DETAILS

Benefits

  • Maximum Fire Safety: Constructed with mica tape, it maintains the integrity of the circuits even under direct fire.
  • Flame Retardant: A compound that does not propagate flames, increasing safety on board.
  • Low Smoke Emission (LSOH): Halogen-free, it ensures visibility during evacuations and protects electronic equipment.
  • Wide Temperature Range: Reliable operation in extreme conditions, from -30°C to +90°C.
  • High Performance Insulation: XLPE insulation offers excellent electrical resistance and durability.
  • Installation Flexibility: Reduced bending radius that facilitates assembly in complex and confined spaces.
  • High Conductivity: Class 5 stranded tinned copper conductors for efficient power transmission.
  • Compliance with Standards: Meets stringent international IEC standards for maritime and offshore use.
  • Versatility of Models: Available in multiple track configurations to suit any project.
  • Long Service Life: Designed for fixed installations, ensuring robustness and low maintenance requirements.

Applications

  • Fixed Installations on Ships: Ideal for general application in all areas on board vessels.
  • Offshore Platforms: Used in power and control circuits on oil and gas platforms.
  • Energy and Power Systems: Power supply for distribution panels, motors, and heavy equipment.
  • Control and Automation Circuits: Connection of instrumentation systems, sensors and naval control panels.
  • Critical Emergency Systems: Power supply for fire pumps, alarms, and emergency lighting.
  • Engine Rooms: Durable enough to operate in environments with high temperatures and constant vibration.
  • Command Bridges: Wiring of essential navigation, communication, and control equipment.
  • Accommodations and Public Areas: Safety for crew and passenger areas due to its LSOH properties.
  • Commercial and Passenger Vessels: A reliable solution for cargo ships, cruise ships, and ferries.
  • Modernization (Retrofit) Projects: A safe choice for upgrading electrical systems on existing vessels.
TECHNICAL DATA
General information
BrandInnovcable
Product LineMariTimus®
Product typeFire-resistant power and control cables for marine/offshore applications (multicore).
CórdobaMariTimus® Fire Resistant Line
Electrical Parameters
Nominal VoltageUo/U: 0,6/1 kV
Product Design
Conductor MaterialBraided tin-plated copper. Bare copper available upon request.
Driver DesignClass 5, braided. Class 2 available upon request.
Base Material for Vein IsolationMica tape + XLPE.
Base Material for the External CoveringLSOH (SHF1). SHF2 available upon request.
Abbreviation for Roofing MaterialLSOH (SHF1)
Cover ColorOrange (based on the diagram).
ShieldedNo (without armor).
Cable FormatRound.
Road IdentificationColored cores or black conduits with numbers for multi-core cables.
Road color code
  • Road Identification according to CENELEC (HD 308 S2):
  • Two options: Brown, Blue.
  • Three options: Brown, Black, Gray.
  • Four colors: Blue, Brown, Black, Gray.
  • Five colors: Blue, Brown, Black, Gray, Black.
  • Multiple tracks: All tracks are black and sequentially numbered. Green/yellow tracks can be supplied upon request.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Blue, Brown.
  • Three-way + ground (4G): Green/Yellow, Brown, Black, Gray.
  • Four-way + ground (5G): Green/Yellow, Blue, Brown, Black, Gray.
Product characteristics
Application AreaFixed installations on board ships, in all locations where mechanical protection of the cable is not required.
Minimum Radius of CurvatureFixed installation: 6 x External Diameter (for OD > 25mm); 4 x External Diameter (for OD ≤ 25mm).
Temperature, fixed installation-30 °C to +90 °C.
Fire resistantYes, in accordance with IEC 60331-21.
Flame retardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Halogen-freeYes, in accordance with IEC 60754-1/2.
Low Smoke EmissionYes, according to IEC 61034.
Applicable Standards
IEC 60092-350/351/353/359
IEC 60331-21
IEC 60332-1
IEC 60332 3 22
IEC 60754-1/2
IEC 61034
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area (mm²))Nominal Insulation Thickness (mm)Nominal Coating Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
2 × 1.50.71.18.585
2 × 2.50.71.19.5110
2 × 40.91.111.7140
2 × 60.91.213.0230
2 × 100.91.214.7330
2 × 160.91.317.0490
2 × 250.91.319.5750
2 × 350.91.522.0990
2 × 501.01.524.81340
3 × 1.50.71.19.5105
3 × 2.50.71.110.0145
3 × 40.91.212.7205
3 × 60.91.213.9270
3 × 100.91.315.9400
3 × 160.91.318.4610
3 × 250.91.521.4920
3 × 350.91.624.21330
3 × 501.01.727.51830
3 × 701.11.832.02570
3 × 951.11.936.43360
4 × 1.50.71.110.0135
4 × 2.50.71.111.2180
4 × 40.91.213.9260
4 × 60.91.215.2350
4 × 100.91.317.4530
4 × 160.91.420.2800
4 × 250.91.523.51230
4 × 350.91.726.71650
5 × 1.50.71.111.0170
5 × 2.50.71.212.5240
7 × 1.50.71.212.6210
7 × 2.50.71.214.1300
12 × 1.50.71.316.5350
12 × 2.50.71.318.6490
19 × 1.50.71.419.6520
19 × 2.50.71.422.1750
27 × 1.50.71.523.3730
27 × 2.50.71.526.41060
37 × 1.50.71.626.3980
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.