Maritimus® Armored Multicore Naval Power and Control Cable; Max. 95,00 mm²; 0,6/1 kV; 2 to 37 conductors; MICA / XLPE / SHF1 / SHF1; Fire Resistant; +90°C; IEC 60092; 60331

MariTimus® Marine Multicore Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 / SHF1 (LSOH) Armored and Fire Resistant IEC 60331

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

MariTimus® Offshore Fire Resistant Marine Cable: Maximum Safety for Critical OperationsDesigned for the integrity of installations aboard ships and platforms, these cables offer superior protection. Their robust construction with advanced shielding ensures operational continuity and total safety in demanding marine environments.
  • Maximum Fire Safety: Fire resistant, flame retardant, and with low emission of toxic smoke.
  • Superior Mechanical Protection: Armor with copper braid that protects against severe impacts and damage.
  • Performance in Extreme Conditions: LSOH (SHF1) cover and XLPE insulation for operation from -30°C to +90°C.
  • Onboard Versatility: Ideal for fixed installations in all areas of vessels requiring protection.
  • Certified Quality and Trust: Developed under strict IEC standards to guarantee the highest performance and safety.
PRODUCT DESIGN
  • Class 5 stranded tinned copper conductor. Bare copper or class 2 conductors can be offered upon request.
  • Insulation: MICA + XLPE fire barriers.
  • Inner Cover: Extruded inner cover (LSOH).
  • Armor: Mesh of tinned copper wires. Bare copper can be supplied upon request.
  • Outer sheath: LSOH (SHF1). SHF2 can be offered upon request.
  • Outer Cover Color: Orange. Available in other colors upon request.
  • Road Identification according to CENELEC (HD 308 S2):
  • Two options: Brown, Blue.
  • Three options: Brown, Black, Gray.
  • Four colors: Blue, Brown, Black, Gray.
  • Five colors: Blue, Brown, Black, Gray, Black.
  • Multiple tracks: All tracks are black and sequentially numbered. Green/yellow tracks can be supplied upon request.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Blue, Brown.
  • Three-way + ground (4G): Green/Yellow, Brown, Black, Gray.
  • Four-way + ground (5G): Green/Yellow, Blue, Brown, Black, Gray.
DETAILS

Benefits

  • Enhanced fire safety: Constructed with mica tape and XLPE insulation, the cable is fire-resistant, ensuring the integrity of the circuits.
  • Robust protection: The tinned copper wire braid armor offers excellent mechanical protection against impacts and crushing.
  • Low smoke emission: LSOH (SHF1) coating produces little smoke in case of fire, improving visibility on escape routes.
  • Halogen-free: Materials that do not emit toxic or corrosive gases when exposed to fire, protecting people and electronic equipment.
  • Flame retardant: The cable limits the spread of fire, a crucial factor for safety in confined environments such as those on ships.
  • Wide temperature range: Reliable operation in temperatures ranging from -30°C to +90°C, suitable for various marine conditions.
  • Compliance with IEC standards: Designed and tested according to rigorous international standards (IEC 60092, 60331, 60332), ensuring high quality.
  • Installation flexibility: Class 5 stranded copper conductors (or class 2 upon request) facilitate handling and installation.
  • Superior durability: The extruded inner lining and LSOH (SHF1) outer coating provide a long service life in marine environments.
  • Circuit integrity: It keeps critical power and control systems operational even during a fire.

Applications

  • Fixed installations on board: Ideal for power distribution and control systems in all areas of ships and vessels.
  • Offshore Platforms: Used in oil and gas installations where fire resistance and mechanical robustness are essential.
  • Passenger ships: Used on cruise ships and ferries to ensure the safety of electrical systems in high-traffic areas.
  • Commercial vessels: Suitable for cargo ships, tankers and bulk carriers, which require highly reliable cables.
  • Emergency systems: Power supply for emergency lighting circuits, fire alarms, and communication systems.
  • Machinery control: Connecting control panels to motors, pumps, and other essential equipment in the engine room.
  • Naval applications: Use in military vessels that require compliance with stringent safety and performance specifications.
  • Areas that require protection: Installation in locations where mechanical protection of the cable is a fundamental requirement for safe operation.
  • Floating production units (FPSOs): Perfect for storage and unloading systems operating in harsh conditions.
  • Naval modernization projects: A versatile solution for upgrading electrical systems in vessel refurbishment projects.
TECHNICAL DATA
General information
BrandInnovcable / MariTimus® Fire Resistant
Product typeFire-resistant, shielded power and control cables for marine/offshore applications.
ApplicationUsed on board ships in all areas for fixed installations where cable protection is required.
Electrical Parameters
Nominal VoltageUo/U: 0,6/1 kV
Product Design
Conductor MaterialTin-plated braided copper wire. Bare copper available upon request.
Driver ClassClass 5 (Class 2 available upon request).
Base Material for Vein IsolationMica tape + XLPE.
Base Material for the Inner CoverExtruded composite (LSOH).
ShieldedYes, tin-plated copper wire mesh. Bare copper available upon request.
Base Material for the External CoveringLSOH (SHF1). SHF2 available upon request.
Cover ColorOrange (as pictured).
Road color code
  • Road Identification according to CENELEC (HD 308 S2):
  • Two options: Brown, Blue.
  • Three options: Brown, Black, Gray.
  • Four colors: Blue, Brown, Black, Gray.
  • Five colors: Blue, Brown, Black, Gray, Black.
  • Multiple tracks: All tracks are black and sequentially numbered. Green/yellow tracks can be supplied upon request.
  • WITH GROUND CONDUCTOR Green/Yellow (optional)
  • Two-way + ground (3G): Green/Yellow, Blue, Brown.
  • Three-way + ground (4G): Green/Yellow, Brown, Black, Gray.
  • Four-way + ground (5G): Green/Yellow, Blue, Brown, Black, Gray.
Mechanical and Thermal Characteristics
For continuous bendingNot specified, designed for fixed installations.
Minimum Radius of Curvature6 times the outside diameter (for fixed installations).
Temperature, fixed installation-30 °C to +90 °C.
Fire Characteristics
Fire resistantYes, in accordance with IEC 60331-21.
Flame retardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Low smoke emissionYes, according to IEC 61034.
Halogen-freeYes, in accordance with IEC 60754-1/2.
Applicable Standards
IEC 60092-350IEC 60331-21
IEC 60092-351IEC 60332-1
IEC 60092-353IEC 60332 3 22
IEC 60092-359IEC 60754-1/2
IEC 61034
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area in mm²)Nominal Insulation Thickness (mm)Nominal Sheath Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
2 × 1.50.71.110.5180
2 × 2.50.71.111.7230
2 × 40.91.212.9290
2 × 60.91.214.8400
2 × 100.91.316.6570
2 × 160.91.419.0770
2 × 250.91.522.81130
2 × 350.91.525.01420
2 × 501.01.528.01860
3 × 1.50.71.111.2210
3 × 2.50.71.112.2260
3 × 40.91.213.5340
3 × 60.91.315.7480
3 × 100.91.317.7680
3 × 160.91.420.0930
3 × 250.91.624.11380
3 × 350.91.626.41770
3 × 501.01.629.62350
3 × 701.12.036.72930
3 × 951.12.142.53870
4 × 1.50.71.112.1250
4 × 2.50.71.212.9300
4 × 40.91.315.4440
4 × 60.91.317.0570
4 × 100.91.419.1810
4 × 160.91.522.21160
4 × 250.91.626.91720
4 × 350.91.729.72220
5 × 1.50.71.212.8280
5 × 2.50.71.214.7400
7 × 1.50.71.214.3370
7 × 2.50.71.215.8480
12 × 1.50.71.417.9570
12 × 2.50.71.420.3780
19 × 1.50.71.520.7790
19 × 2.50.71.523.41070
27 × 1.50.71.724.41100
27 × 2.50.71.727.91500
37 × 1.50.71.927.31380
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.