Maritimus® Single-Core Marine Power and Control Cable; Shielded; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / HEPR / SHF1; Fire Resistant; +90°C; IEC 60092; 60331

MariTimus® Single-Core Marine Power and Control Cable 0,6/1 kV MICA / HEPR / SHF1 (LSOH) Shielded and Fire Resistant IEC 60331

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 "The exact total amount, applying the discounts for your volume bracket, will be automatically calculated in your cart."

MariTimus® High-Performance Fire Resistant Marine Cable for Unsurpassed SafetyDesigned for the most extreme conditions on ships and offshore units, this cable ensures that safety circuits and critical installations operate with maximum reliability, protecting lives and equipment against the threats of fire and electrical interference.
  • Maximum Fire Safety: Fire-resistant, flame-retardant, and halogen-free, ensuring safe evacuation in accordance with IEC 60331.
  • Superior Electromagnetic Protection: Copper braid shielding reduces interference, protecting sensitive electronic systems.
  • High-quality and durable compounds: Low smoke emission LSOH (SHF1) coating, ideal for confined areas.
  • Versatile and Safe Installation: Perfect for fixed installations on open decks and in safety circuits.
  • A Smart Investment: Ensure the integrity of your operations with a cable designed to last in the harshest environments.
PRODUCT DESIGN
  • Class 5 stranded tinned copper conductor. Bare copper or class 2 conductors can be offered upon request.
  • Isolation: MICA + HEPR fire barriers.
  • Armor: Mesh of tinned copper wires. Bare copper can be supplied upon request.
  • Outer sheath: LSOH (SHF1). SHF2 can be offered upon request.
  • Single core: Natural color (beige).
  • Outer Cover Color: Orange. Available in other colors upon request.
DETAILS

Benefits

  • Maximum Fire Safety: Cable with high fire resistance, designed to maintain the integrity of safety circuits.
  • Fire Protection: Flame-retardant properties that hinder the spread of fire in case of a fire.
  • A Safer Environment: LSOH (Low Smoke Zero Halogen) coating ensures low emission of smoke and toxic gases.
  • Signal without interference: Shielding with tinned copper braid offers effective protection against electromagnetic and radio interference.
  • High Performance Insulation: Composed of HEPR with fire-resistant barriers, ensuring electrical and thermal reliability.
  • Wide Temperature Range: Safe and reliable operation in temperatures ranging from -20°C to +90°C.
  • High Conductivity: Class 5 stranded copper conductor that ensures efficient power transmission.
  • Ease of Installation: Optimized bending radius that facilitates mounting in fixed and complex installations.
  • Durability in Harsh Environments: Built to withstand the harsh conditions of naval and offshore installations.
  • Compliance with Standards: It meets stringent international industry standards, such as IEC 60092-353 and IEC 60331-21.

Applications

  • Offshore Platforms: Power supply and control systems in drilling and production units.
  • Passenger and Cargo Ships: Electrical distribution in machine rooms, passageways and common areas.
  • Critical Safety Circuits: Ideal for alarm systems, fire pumps and emergency lighting.
  • Open Deck Facilities: Perfect for circuits exposed to marine environments, where durability is essential.
  • Naval Control Systems: Connection of control panels, automation and instrumentation on board.
  • Electronic Equipment: Protects navigation and communication systems against electrical interference.
  • Support Vessels: Used on tugboats, supply vessels (PSVs), and other service vessels.
  • Shipyards: Used in new construction and naval repair projects that require maximum safety.
  • Propulsion Systems: Wiring of electrical components in propulsion and control systems.
  • Floating Production Storage and Offloading (FPSO) Units: For fixed installations in floating production, storage and transfer units.
TECHNICAL DATA
General information
BrandInnovcable
Product LineMariTimums® Fire Resistant 0.6/1 kV
Product typeFire-Resistant Power and Control Cables for Marine and Offshore Applications (Single-Line Diagram).
Application AreaFor fixed installations on ships and offshore units in all locations and on open decks in safety circuits where fire resistance is required. The good quality of the shielding also reduces radio interference and electrical influences on electronic installations.
Electrical Parameters
Nominal Voltage0.6 / 1 kV
Product Design
Conductor MaterialBraided tin-plated copper. Can be supplied in bare copper upon request.
Driver DesignClass 5 stranded copper conductor. Class 2 can be supplied upon request.
 Base Material for Vein IsolationFire barriers MICA TAPE + HEPR (High-quality ethylene propylene rubber).
shieldingTin-plated copper wire mesh. Can be supplied in bare copper upon request.
Base Material for the External CoveringLSOH (SHF1) - Low smoke emission and zero halogen. Orange color, other colors can be supplied upon request.
Road IdentificationNatural color (beige).
Product characteristics
Fire resistantYes, in accordance with IEC 60331-21.
Flame retardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Halogen-freeYes, in accordance with IEC 60754-1/2.
Low smoke emissionYes, according to IEC 61034.
Minimum Bending Radius (fixed installation)6 x outer diameter.
Temperature Range-20 °C to +90 °C.
Dimensions and Weight (Varies by Model)
MFX300-1mG7MZ1-R-1C25Section: 1x25 mm², External Ø: 12.5 mm, Weight: 380 kg/km
MFX300-1mG7MZ1-R-1C35Section: 1x35 mm², External Ø: 13.5 mm, Weight: 480 kg/km
MFX300-1mG7MZ1-R-1C50Section: 1x50 mm², External Ø: 15.5 mm, Weight: 670 kg/km
MFX300-1mG7MZ1-R-1C70Section: 1x70 mm², External Ø: 17.5 mm, Weight: 900 kg/km
MFX300-1mG7MZ1-R-1C95Section: 1x95 mm², External Ø: 19.5 mm, Weight: 1170 kg/km
MFX300-1mG7MZ1-R-1C120Section: 1x120 mm², External Ø: 21.0 mm, Weight: 1430 kg/km
Applicable Standards
DIN 89160/98IEC 60332-1
IEC 60092-353IEC 60332 3 22
IEC 60331-21IEC 60754-1/2
IEC 61034
DIMENSIONAL TABLE
Construction
(Number of conductors x Cross-sectional area in mm²)
Nominal Insulation Thickness
(mm)
Nominal Sheath Thickness
(mm)
Nominal Outside Diameter
(mm)
Nominal Weight
(kg/km)
1 × 250.91.212.5380
1 × 350.91.213.5480
1 × 501.01.315.5670
1 × 701.11.417.5900
1 × 951.11.419.51170
1 × 1201.61.521.01430
SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.