Maritimus® Single-Core Marine Power and Control Cable; Max. 120,00 mm²; 0,6/1 kV; 1 conductor; MICA / XLPE / SHF1; Fire Resistant; +90°C; IEC 60092; 60331

MariTimus® Marine Single-Core Power and Control Cable 0,6/1 kV MICA / XLPE / SHF1 (LSOH) Fire Resistant IEC 60331

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

MariTimus® Fire Resistant Marine Cable: Essential Safety for Offshore and Marine ApplicationsDesigned for the harsh conditions aboard ships, this single-core cable ensures safe and reliable fixed installations. Its superior construction guarantees the continuity of power and control systems even during a fire, protecting lives and property.
  • Superior Fire Resistance: Mica tape ensures circuit integrity in the event of fires, keeping critical systems functioning.
  • High Performance Insulation: XLPE offers excellent electrical performance and durability in demanding marine environments.
  • Human Security (LSOH): Low smoke and zero halogens for safe evacuations, without toxic or corrosive gases.
  • Flame Retardant: It actively limits the spread of fire, increasing the overall safety of your vessel.
  • Specific Naval Application: Ideal for fixed installations on ships where no additional mechanical protection is required.
PRODUCT DESIGN
  • Conductors: Class 5 stranded tinned copper conductor. Class 2 can be offered upon request.
  • Insulation: Mica tape + XLPE.
  • Outer Sheath: LSOH (SHF1). SHF2 can be offered upon request.
  • Outer Cover Color: Orange. Other colors available upon request.
DETAILS

Benefits

  • Enhanced Security: Fire resistant, ensuring the integrity of circuits in emergencies.
  • Flame Retardant: It minimizes the risk of fire spreading on board.
  • Halogen-Free (LSOH): It does not emit toxic or corrosive gases when exposed to fire.
  • Low Smoke Emission: It preserves visibility on escape routes and facilitates firefighting.
  • Wide Temperature Range: Reliable operation in extreme conditions, from -30°C to +90°C.
  • Superior Insulation: Mica tape and XLPE insulation offer excellent electrical performance.
  • Installation Flexibility: Designed for tight bending radii, facilitating mounting in compact spaces.
  • Reliable Conductivity: Braided copper conductors that ensure a stable electrical connection.
  • Robust Construction: Ideal for marine environments, withstanding harsh conditions.
  • Compliance with Standards: Meets stringent international IEC standards for naval and offshore applications.

Applications

  • Fixed Installations on Ships: For power distribution and control in all areas on board.
  • Emergency Systems: Power supply for security, lighting and alarm circuits.
  • Naval Industry: Used in shipyards for the construction and repair of vessels.
  • Offshore Platforms: Electrical connections in oil and gas drilling and production units.
  • Commercial Vessels: Applications in cargo ships, tankers and container ships.
  • Passenger Ships: Facilities on cruise ships, ferries and other transport vessels.
  • Machine and Control Rooms: Connection of panels, motors and automation equipment.
  • Deck Equipment: Power supply for navigation and communication systems.
  • Power and Control Circuits: Ideal for installations that do not require additional mechanical protection.
  • Special Maritime Projects: A versatile solution for diverse electrical needs in the marine sector.
TECHNICAL DATA
General information
BrandInnovcable
Product LineMariTimus®
Product typeSingle-core, fire-resistant power and control cable for marine/offshore applications.
Electrical Parameters
Nominal Voltage0.6 / 1 kV
Product Design
Conductor MaterialBraided tin-plated copper. Bare copper also available upon request.
Driver DesignClass 5 braided. Class 2 available upon request.
Cable FormatRound
Base Material for Vein IsolationMica tape + XLPE.
Base Material for the External CoveringLSOH (SHF1). SHF2 available upon request.
Abbreviation for Roofing MaterialLSOH (SHF1)
Cover ColorOrange (as pictured).
Road IdentificationLaser printed.
Product characteristics
Application AreaFixed installations on board ships, in all locations where cable protection is not required.
For continuous bendingNo, it's designed for fixed installations.
Minimum Radius of Curvature6×OD (OD>25mm)
4×OD (OD ≤25mm)
Temperature Range-30 ° C to + 90 ° C.
fire resistantYes, in accordance with IEC 60331-21.
Flame retardantYes, in accordance with IEC 60332-1 and IEC 60332-3-22.
Halogen-freeYes, in accordance with IEC 60754-1/2.
Low smoke emissionYes, according to IEC 61034.
Applicable Standards
Construction and TestingIEC 60092-350, IEC 60092-351, IEC 60092-353, IEC 60092-359
Fire resistanceIEC 60331-21
Flame PropagationIEC 60332-1, IEC 60332-3-22
Smoke and Halogen EmissionIEC 60754-1/2, IEC 61034
DIMENSIONAL TABLE
Construction (Number of conductors x Cross-sectional area in mm²)Nominal Insulation Thickness (mm)Nominal Sheath Thickness (mm)Nominal Outside Diameter (mm)Nominal Weight (kg/km)
1 × 250.91.110.7310
1 × 350.91.112.0410
1 × 501.01.213.6560
1 × 701.11.315.8780
1 × 951.11.317.71030
1 × 1201.21.419.71290
RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products under production: To ensure maximum quality and flexibility, many of our cables are produced on demand (make-to-orderIn these cases, the production and dispatch timeframe is... 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you. after Our dispatch time. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.