Busbar cable; PROFIBUS DP; Fixed installation; Nominal characteristic impedance: 150 Ω; 1x2x0,64; SHF2; Flame retardant: IEC 60332-1-2; violet; 8 mm

Profibus DP DeepSea® Armed SHF2

Rodent protection?

Provides extra protection against rodents and termites. The price will be updated in your cart.

💡 Add to cart — Immediate purchase. The discount for your volume bracket is automatically applied, and you complete the order online.
📋 Add to quote request Our team will analyze and get back to you with a proposal. Ideal for large volumes, special deadlines, or when you need to add cables that are not available for sale online.

Profibus DP DeepSea® ARMADO SHF2: The Ultimate Connection for Offshore EnvironmentsOvercome the challenges of the maritime environment with this high-performance cable. Designed specifically for ships and offshore platforms, it combines mechanical robustness with precise data transmission, ensuring the operational continuity of your automation and control systems in extreme conditions.
  • DNV Certification: Proven quality with naval certification, ensuring compliance with the most stringent international safety standards.
  • Mechanical Armor: Armor made of galvanized steel wire braid that offers superior protection against physical impacts and severe abrasion on the deck.
  • SHF2 Resistance: Robust and UV-resistant outer coating, protected from oils and weathering, designed to withstand salinity and harsh climates.
  • Advanced Security: Halogen-free and flame-retardant material (IEC 60332-3-22 Cat.A), protecting lives and critical equipment in case of fire.
  • High performance: Optimized for Profibus DP industrial networks, ensuring signal stability and controlled impedance for process automation.
Product Design
  • Application: Busbar cable for industrial, naval and offshore automation (fixed installation)
  • Nominal characteristic impedance: 150 Ω (@ 3-20 MHz)
  • Conductor material: Bare or tinned stranded copper
  • Conductor construction: 1 pair of 0,35 mm² (22/7 AWG)
  • Conductor insulation: Foam-Skin PE
  • Shielding: Al/Mylar tape and tinned copper braid
  • Inner cover: SHF1 Black
  • Frame: Galvanized steel wire braid (coverage ≥65%)
  • Outer casing material: SHF2 (Halogen-free, UV resistant)
  • Cover color: Black
  • Nominal outer diameter: 11,0 mm
  • Minimum radius of curvature: 10 x outer diameter
  • Temperature range (normal operation): -40°C to +80°C
  • Flame retardancy: In accordance with IEC 60332-3-22 Cat.A
Details

Benefits

  • Mechanical Protection: Impact-resistant galvanized steel wire braid armor (GSWB).
  • SHF2 coating: Robust, reticulated outer shell, ideal for harsh marine environments.
  • UV resistance: Guaranteed protection against ultraviolet radiation in accordance with ASTM D 4587 standard.
  • Fire Safety: Flame retardant (IEC 60332-3-22 Cat.A) and low smoke emission.
  • Halogen-free: LSZH material that prevents toxic and corrosive gases in case of fire.
  • Temperature Range: Safe operation from -40°C to +80°C, withstanding extreme weather conditions.
  • EMC Shielding: Aluminum/Mylar tape and copper braid protect against interference.
  • High Quality Signal: Conductors designed to maintain stable impedance in Profibus networks.
  • Flexible Construction: Stranded conductors that facilitate installation in confined spaces.

Applications

  • Offshore Environments: Oil platforms, cargo ships and fixed offshore structures.
  • Naval Automation: Control of processes and communication systems on board.
  • PROFIBUS DP Networks: High-speed data transmission for fieldbuses.
  • Machine Rooms: Installations subject to heat and vibration that require mechanical protection.
  • External Areas: Connections on open decks exposed to sun and weather.
  • Safety Zones: Confined spaces where low smoke emission is mandatory.
  • Fixed Installation: Cable routing in trays, conduits, and control panels.
  • Naval Industry: Construction of cruise ships, oil tankers and support vessels.
  • Instrumentation: Connecting sensors and actuators in distributed automation systems.
  • Aggressive Environments: Locations with a risk of mechanical damage and moderate chemical exposure.
Technical Data
General information
BrandINNOVCABLE® (DeepSea®)
Product's nameProfibus DP DeepSea® Armed SHF2
Product typeArmed Profibus DP Data Cable (Flexible type A)
 Frame Available in: (Steel Armor) / (Copper Armor) / (Tin-Plated Copper)
Electrical Parameters
Characteristic Impedance (3-20 MHz)150 ± 15 Ω
Impedance (9.6 kHz)270 ± 27 Ω
Impedance (38.4 kHz)185 ± 18.5 Ω
Conductor Resistance≤ 55 Ω/km
Insulation Resistance≥ 1 GΩ x km
Capacitance (800-1000 Hz)30pF/m
Test VoltageDC 1kV / 1 min
Speed ​​Factor78 %
Attenuation (16 MHz)≤ 42.0 dB/km (Nominal < 4.5 dB/100m)
Product Design
Conductor MaterialBare or tinned copper, stranded
Conductor Dimension7 x 0.254 mm (AWG 22/7) - 0.35 mm²
Vein IsolationFoam-skin PE (Expanded Polyethylene) - Ø 2.55 mm
Number of Pairs1 par
Color CodeRed, Green
Shielding (Screen)Aluminum/Mylar tape + tinned copper braid
Inner LayerSHF1 Black
ArmorGalvanized Steel Wire Braid (Coverage ≥ 65%) or Copper Wire Braid or Tin-Plated Copper Wire Braid
Outer CoverSHF2 Black (Halogen-Free, Cross-linked)
External Diameter (OD)11.0 mm
Weight190kg/km
Mechanical and Environmental Characteristics
Application AreaNaval and Offshore Use (Ships and Platforms), Industrial Automation.
InstallationFixed applications.
Operating Temperature-40 ° C to + 80 ° C
Installation Temperature-20 ° C to + 60 ° C
Minimum Radius of Curvature10 x External Diameter (Fixed) / 20 x External Diameter (Flexible)
UV resistantYes (Per UL 1581 / ASTM D 4587)
Halogen-freeYes (IEC 60754-1 & IEC 60754-2)
Low Smoke EmissionYes (IEC 61034-2)
Flame RetardantYes (IEC 60332-1, IEC 60332-3-22 Cat. A)
Mud Resistance (MUD)Optional (Available upon request)
Rules
Material StandardsIEC 60092-360 (SHF2)
ConformityCE, ROHS
Dimensional Table
Product descriptionConductors / ConstructionExternal Diameter (mm)Total Weight (kg/km)
Profibus DP DeepSea® ARMED SHF2 (Steel Armor)1x2x0.35 mm² (Stranded)11.0190
Profibus DP DeepSea® ARMED SHF2 (Copper Armor)1x2x0.35 mm² (Stranded)11.0*190*
Profibus DP DeepSea® Armed SHF2 Tinned1x2x0.35 mm² (Stranded)11.0*190*
Profibus DP DeepSea® ARMED SHF2 (Mud Resistant)1x2x0.35 mm² (Stranded)11.0*190*

*Note: Armor (Copper) or composite (MUD) variants may exhibit slight weight variations not explicitly specified in the document's general table.

RELATED PRODUCTS

SHIPPING AND DELIVERY TIMES

Shipping and Delivery Times – FAQ

Q: How does product shipping work?

A: We ship throughout Brazil. We work with the Post Office (SEDEX and PAC) and several partner carriers. When you finalize your purchase, our system calculates and presents the best shipping options available for your zip code, based on the weight and dimensions of your order.

Q: What is the delivery time for my order?

A: Our total delivery time is the sum of two stages: Availability Time + Carrier Time.

  • Availability Period:

    • Products in Stock: If the product is in stock, it will be shipped within 2 business days.

    • Products Made to Order: To ensure maximum quality and flexibility, many of our cables are made to order . In these cases, the production and shipping time is 15 business days.

  • Carrier's deadline:

    • This is the time it takes for the shipping to reach you after we dispatch it. This timeframe is shown when calculating shipping costs in your shopping cart.

Therefore, for a product that is in production, the total estimated delivery time will be 15 business days plus the shipping time.

Q: Why the 15 business day production lead time? What if there are delays?

A: Our on-demand production model allows us to offer superior industrial-quality cables, in the exact length you need, and at extremely competitive prices. As a manufacturing unit, our production process involves several variables, such as receiving raw materials and operating complex machinery. We understand that unforeseen events can occur. Should any event arise that could impact the 15-business-day timeframe, our team will proactively contact you to keep you informed of the new schedule. We are committed to complete transparency throughout the entire process.

Q: Can I cancel an order that is already in production?

A: For products manufactured on demand (make-to-order model), we do not accept cancellations once the order enters our production line. This is because, to ensure speed and competitive pricing, the raw materials for your cable are separated and allocated, and the manufacturing process begins immediately after payment confirmation. Please review your order carefully before finalizing it. If you have any questions, please contact our team.

Shipping Costs

Q: How is the shipping cost calculated?

A: The value is automatically calculated in your shopping cart, based on the total weight of the products, the dimensions of the packaging, and the destination zip code entered.

Q: Do you offer free shipping?

A: We don't currently have a fixed free shipping policy. Occasionally, we may run specific promotions. The most accurate way to check the cost for your location is to add the desired products and your zip code to your cart.

Warranty and Returns

Q: What is the return and exchange policy?

A: According to our policy and the Consumer Protection Code, we accept returns due to buyer's remorse or manufacturing defects within 7 (seven) calendar days of receiving the product. To initiate the process, please contact our Customer Service Center via email. ecommerce@innovcable. Com.br Please provide the order number and reason for the return. The product must be returned in its original packaging, undamaged and showing no signs of misuse. We emphasize that this return policy remains valid and unchanged after receipt.

Q: Do the products have a warranty?

A: Yes. All cables in our product line are guaranteed against manufacturing defects. The specific warranty period can be found on each product page. The warranty does not cover damage caused by incorrect installation, misuse, or natural wear and tear from use.

Loading and Transportation

1. When lifting with a crane, the correct rope must be used, attached to an axle located in the center of the coil.

* Heads up:
– Move it as close to the ground as possible.
Move slowly and, once in the correct position, do not stop abruptly.


2- In the case of a forklift, the drums must not be damaged by the forklift.

* Heads up:
Place the coil in the center of the fork.
The width of the fork must be greater than the spool.

Transportation and unloading

✽ Precautions when handling cables:
• Do not cover the coils.
• Do not roll more than 20 m.
• Do not use sharp objects when moving.
• Do not roll a damaged coil.
• Do not roll on uneven surfaces.
• Do not store the coil near heaters or flammable materials.
 

Checks when handling cables – Storage

• Do not remove the protective materials and packaging that protect the reels and cables until they are used.
• Store in a protected or enclosed location to protect against damage from machinery.
• Store in a suitable, closed storage location for extended periods. (Coils and packaging should be kept in a dry place.)
• Seal both ends of the remaining cables on the reels using heat-shrink tubing to prevent moisture absorption.